Age-related macular degeneration (AMD) is a progressive disease of the retinal pigment epithelium (RPE) and the retina leading to loss of central vision. Polymorphisms in genes involved in lipid metabolism, including the ATP-binding cassette transporter A1 (ABCA1), have been associated with AMD risk. However, the significance of retinal lipid handling for AMD pathogenesis remains elusive. Here, we study the contribution of lipid efflux in the RPE by generating a mouse model lacking ABCA1 and its partner ABCG1 specifically in this layer. Mutant mice show lipid accumulation in the RPE, reduced RPE and retinal function, retinal inflammation and RPE/photoreceptor degeneration. Data from human cell lines indicate that the ABCA1 AMD risk-conferring allele decreases ABCA1 expression, identifying the potential molecular cause that underlies the genetic risk for AMD. Our results highlight the essential homeostatic role for lipid efflux in the RPE and suggest a pathogenic contribution of reduced ABCA1 function to AMD.
Objectives: This study entailed a weekly analysis of real-world data (RWD) on the safety and efficacy of intravitreal (IVT) faricimab in neovascular age-related macular degeneration (nAMD). Methods: A retrospective, single-centre clinical trial was conducted at the Department of Ophthalmology, University Hospital Zurich, University of Zurich, Switzerland, approved by the Cantonal Ethics Committee of Zurich, Switzerland. Patients with nAMD were included. Data from patient charts and imaging were analysed. The safety and efficacy of the first faricimab injection were evaluated weekly until 4 weeks after injection. Results: Sixty-three eyes with a complete 4-week follow-up were enrolled. Six eyes were treatment-naïve; fifty-seven eyes were switched to faricimab from another treatment. Neither group showed signs of retinal vasculitis during the 4 weeks after injection. Central subfield thickness (CST) and volume (CSV) showed a statistically significant decrease compared to the baseline in the switched group (CST: p = 0.00383; CSV: p = 0.00702) after 4 weeks. The corrected visual acuity returned to the baseline level in both groups. The macular neovascularization area decreased in both groups, but this was not statistically significant. A complete resolution of sub- and intraretinal fluid after 4 weeks was found in 40% (switched) and 75% (naïve) of the treated patients. Conclusions: The weekly follow-ups reflect the structure–function relationship beginning with a fast functional improvement within two weeks after injection followed by a return to near-baseline levels after week 3. The first faricimab injection in our cohort showed a high safety profile and a statistically significant reduction in macular oedema in switched nAMD patients.
Purpose: To assess the usability and image quality of a smartphone adapter for direct slit lamp imaging. Methods: A single-center, prospective, clinical study conducted in the Department of Ophthalmology at the University Hospital Zurich, Switzerland. The smartphone group consisted of 26 medical staff (consultants, residents, and students). The control group consisted of one ophthalmic photographer. Both groups took images of the anterior and the posterior eye segment of the same proband. The control group used professional photography equipment. The participant group used an Apple iPhone 11 mounted on a slit lamp via a removable SlitREC smartphone adapter (Custom Surgical GmbH, Munich, Germany). The image quality was graded independently by two blinded ophthalmologists on a scale from 0 (low) to 10 (high quality). Images with a score ≥ 7.0/10 were considered as good as the reference images. The acquisition time was measured. A questionnaire on usability and experience in smartphone and slit lamp use was taken by all of the participants. Results: Each participant had three attempts at the same task. The overall smartphone quality was 7.2/10 for the anterior and 6.4/10 for the posterior segment. The subjectively perceived difficulty decreased significantly over the course of three attempts (Kendall’s W). Image quality increased as well but did not improve significantly from take 1 to take 3. However, the image quality of the posterior segment was significantly, positively correlated (Spearman’s Rho) with work experience. The mean acquisition time for anterior segment imaging was faster in the smartphone group compared to the control group (156 vs. 206 s). It was vice versa for the posterior segment (180 vs. 151 s). Conclusion: Slit lamp imaging with the presented smartphone adapter provides high-quality imaging of the anterior segment. Posterior segment imaging remains challenging in terms of image quality. The adapter constitutes a cost-effective, portable, easy-to-use solution for recording ophthalmic photos and videos. It can facilitate clinical documentation and communication among colleagues and with the patient especially outside normal consultation hours. Direct slit lamp imaging allows for time to be saved and increases the independence of ophthalmologists in terms of patient mobility and the availability of photographic staff.
Purpose: To compare retinal changes in young adults with previous SARS-CoV-2 infection with healthy young controls using optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA). Methods: This prospective single-center study was conducted at the University Hospital of Zurich, Zurich, Switzerland. Participants were imaged from May to November 2021 using the SOLIX device (Visionix International SAS, Pont-de-l’Arche, France). We performed 12 mm × 12 mm, 6.4 mm × 6.4 mm, 6 mm × 6 mm and 3 mm × 3 mm OCT and OCTA scans, as well as fundus photography of each participant’s eyes. Results: In total, 466 participants were imaged. Of these, 233 were healthy controls with negative RT-PCR tests for SARS-CoV-2, 168 were young adults who had a SARS-CoV-2 infection at least 180 days previously, 19 were participants who had a SARS-CoV-2 infection < 180 days previously, and 46 were participants with asymptomatic SARS-CoV-2 infection (i.e., serologically positive but with no symptoms). Compared with healthy controls, statistically significant differences were found for OCTA recordings of the optic disc for the whole image (WI) and WI capillary vessel density, with both being higher in the SARS-CoV-2 group. Conclusion: Statistically significant results were only observed for selected variables, and in parts, only unilaterally, with relatively large p values (p = 0.02–0.03). Thus, we did not interpret these as clinically significant, leading to the conclusion that young and otherwise healthy individuals (mainly men) seem to recover from mild COVID-19 infections with no ophthalmological residues.
23 April 2024 in Klinische Monatsblätter für Augenheilkunde
Purpose To introduce a novel technique of the aseptic manufacture of autologous serum eye drops (ASEDs) with a prefiltered closed system and to analyze the sterility of the produced ophtioles between 2018 and 2022. Methods This is a prospective single-center study conducted at the Department of Ophthalmology at a Swiss University Hospital between 2018 and 2022. For regulatory reasons, closed systems for manufacturing ASEDs are strongly recommended. We attached an upstream sterile filter (Sterivex PES0.22 µm Burlington, USA) to a commercially available closed system (COL System Modena, Italy) for manufacturing ASEDs. The goal of this novel approach was to reduce the microbiological contamination of the donated autologous blood. Using the presented manufacturing method, we are able to produce, on average, 56 ophtioles per batch, containing either 1.45 mL or 2.5 mL of autologous serum per ophtiole. For each batch of ASEDs, we performed a microbiological analysis by automated blood culture testing (BACTEC). This system examines the presence of bacteria and fungi. Results We analyzed all manufactured batches between 2018 and 2022. None of the 2297 batches and the resulting 129 060 ophtioles showed bacterial or mycotic contamination. During the analyzed period, two batches were discarded: one due to fibrin-lipid aggregations, further microbiological and histological work-up excluded any contamination; another due to false-positive HIV in serological testing. Overall, the contamination rate was 0%, and the batch discharge rate was 0.09%. Conclusions The combination of upstream sterile filtration with a commercial closed system for manufacturing ASEDs proved to be effective in ensuring sterility without any contamination over the past 4 years. This is becoming crucial, as the demand for autologous blood products for treating ocular surface disorders, such as refractory dry eyes or nonhealing defects of the corneal epithelium, is on the rise.
Ophthalmologists’ diagnostic and treatment competence in Acanthamoeba keratitis varies widely. This investigator-initiated, retrospective, single-center chart review examined the electronic patient files regarding PCR-positive Acanthamoeba keratitis. We included corneal and contact lens assessments. We further reviewed the patient’s medical history, corneal scraping results regarding viral or fungal co-infections, and the duration from symptom onset to final diagnosis. We identified 59 eyes of 52 patients from February 2010 to February 2023, with 31 of 52 (59.6%) being female patients. The median (IQR, range) patient age was 33 (25.3 to 45.5 [13 to 90]) years, and the mean (SD, range) time to diagnosis after symptom onset was 18 (10.5 to 35 [3 to 70]) days. Overall, 7 of 52 (7.7%) patients displayed a bilateral Acanthamoeba infection, and 48 (92.3%) used contact lenses at symptom onset. Regarding other microbiological co-infections, we found virologic PCR testing in 45 of 52 (86.5%) patients, with 3 (6.7%) positive corneal scrapings. Fungal cultures were performed in 49 of 52 (94.2%) patients, with 5 (10.2%) positive corneal scrapings. The medical treatment success rate was 45/46 (97.8%). This study raises awareness of patient education in contact lens handling and screens for further microbial co-infections in suspected Acanthamoeba cases.