FNFacultatea de Inginerie Electrică Universitatea Tehnică din Cluj - Napoca
Facultatea de Inginerie Electrică Universitatea Tehnică din Cluj - Napoca
In the paper, the electromagnetic transient process caused by the sudden three-phase short circuit at the terminals of the three-phase stator inductor winding in star connection (with the neutral point of the star isolated) of a three-phase (asynchronous) induction motor – having the polyphase induced winding rotor (cage type) in short circuit and in uniform rotational motion – is analyzed using the linear complex differential equations of the electromagnetic model in spatial phasors representative of the Engine. The analysis of the electromagnetic transient process is corroborated by the numerical results of a conclusive case study.
7 February 2025 in Electric Machines, Materials and Drives — Present and Trends
The paper presents a method for determining the electromagnetic parameters of the linear dynamic model of the induction motor with a three-phase stator winding in a star connection (with the star neutral point isolated) and a polyphase rotor winding (simple cage type) in the short circuit - based on the transient response test in the stator phase electric current intensity, upon the sudden connection of a direct voltage source in the electrical circuit of the stator phase windings A and B, corresponding to the particular topology of the three-phase stator electrical circuit, in which the stator phase windings B and C have galvanically connected input terminals.