Studying the energy use behavior of occupants is crucial for accurately predicting building energy consumption. However, few studies have considered the impact of occupant behaviors on energy consumption in university dormitories. The objective of this study is to establish an agent-based model of energy consumption for university dormitories based on energy use behavior. The dormitories of a typical university in Sichuan, China, were subdivided into three clusters using a two-step cluster analysis. Subsequently, the energy use behaviors of occupants in each type of dormitory were characterized to establish a stochastic energy use behavior model. On the basis of the above, NETLOGO was used to construct an agent-based model for dormitories’ energy consumption to dynamically simulate energy use behavior. The accuracy of the model was verified by comparing the simulated values with the measured data. Finally, a building-energy-friendly retrofit scheme was proposed, and it was found that the optimized dormitory reduced energy consumption by 16.07%. Therefore, the results can provide information support for energy-saving decisions during the early design and retrofit phases of buildings. With the popularity of centralized supply, the research methodology may provide an extensive reference for energy management policies and sustainable strategies in the building sector.
Landscape elements have become an important means to improve the quality of life of residents because of their direct influence on the thermal environment, but the selection and configuration of landscape elements have different effects on human thermal comfort in different climate conditions. In this research, the typical residential area of Lhasa in Tibet was taken as the research object, the experimental scheme was prepared using an orthogonal test, and the simulation was carried out using ENVI-met to explore the influences of the green configuration, water area, and ground reflectance, as well as their interaction with the thermal environment in winter and summer under alpine climate conditions. Taking the physiological equivalent temperature (PET) as the optimization index, the optimal design scheme for the synergistic effect of the residential landscape elements was determined. The results were as follows. (1) The order of the landscape configuration factors was as follows: green configuration > water area > leaf area index > ground reflectance in summer. In winter, the order was green configuration > water area > ground reflectance > leaf area index (LAI). (2) With the combined driving of the orthogonal test and the numerical simulation, the optimal scheme of the landscape elements was determined, which was “tree shrub lawn, water area ratio 16%, ground reflectance 0.5, and LAI = 3 m2/m3”. (3) Finally, the optimal design strategy of the landscape configuration was proposed for the typical outdoor active space of the Lhasa residential area.
The synergistic active-passive utilization of solar energy in buildings plays an important role in achieving nearly zero-energy buildings. Building-integrated photovoltaic (BIPV) is a crucial initiative to reduce heating energy consumption, especially in cold climate zones with abundant solar radiation. However, few studies have examined the impact of design parameters of photovoltaic combined vacuum glazing (PVCVG) on building energy efficiency in Lhasa. This study assessed the energy performance of several typical windows and PVCVG with various Window-to-Wall Ratio (WWR) design conditions and investigated how the WWR and orientation of PVCVG influence energy consumption using DesignBuilder7.0 software. The findings indicate that PVCVG exhibits great energy-saving potential in Lhasa, with both orientation and WWR of PVCVG substantially affecting energy consumption. Specifically, when the south-facing WWR exceeds 40%, the energy generated by the three kinds of PV windows can meet the building’s requirements. The optimal orientation for PVCVG is southward, followed by east and west orientations. PVCVG reaches optimal energy satisfaction when the south WWR is 85%. This study is expected to provide useful information for improving energy use efficiency in cold climate zones with abundant solar radiation and promoting sustainable building development.
Synergistic active-passive utilization of solar energy in buildings plays an important role in achieving nearly zero energy buildings. Building-integrated photovoltaic (BIPV) is a crucial initiative to reduce heating energy consumption, especially in cold climate zones with abundant solar radiation. However, few studies have examined the impact of design parameter of photovoltaic combined vacuum glazing (PVCVG) on building energy efficiency. This study assessed the energy performance of Several typical Win-dows and PVCVG with various Window-to-Wall Ratio (WWR) design conditions in residential buildings in Lhasa, and investigated how the WWR and orientation of PVCVG influence energy consumption by DesignBuilder software. The findings indi-cate that PVCVG exhibits great energy-saving potential in Lhasa, with both orientation and WWR of PVCVG substantially affecting energy consumption. Specifically, When the south-facing WWR > 40%, the energy generated by the three kinds of PV Windows can meet the building's requirements. the optimal orientation for PVCVG is southward, followed by east and west orientations. PVCVG reaches optimal energy satisfaction when the South WWR is 85%. This study is expected to provide useful information for improving the energy use efficiency in cold climate zones with abundant solar radiation and promoting sustainable building development.
The heating load of residential buildings is closely related to the local microclimate. However, there is a lack of quantitative indicators for assessing the impact of the outdoor microclimate on building heating loads in Lhasa residential buildings. This study established an analytical relationship between surface temperature and building heating load through theoretical derivation. Simulations of the outdoor microclimate and building surface temperatures were conducted using Phoenics2019 and Ladybug1.8.0 tools. Statistical models were developed to correlate outdoor microclimate parameters with the surface temperatures of both transparent and opaque building envelopes. Ultimately, these individual models were integrated to form a comprehensive framework for directly calculating heating loads from microclimate data. The model validation results indicate that the Coefficient of Variation of the Root Mean Square Error (CV(RMSE)) is 12.87%, which meets the ASHRAE Guideline 14 international standard requirement of ≤30% for hourly data. The Normalized Mean Bias Error (NMBE) is –9.76%, also satisfying the ASHRAE Guideline 14 criterion of ±10% for hourly data. These results suggest that the model exhibits a minor underestimation, which is acceptable from an engineering perspective. The proposed model can provide a quantitative reference to a certain extent for the comprehensive evaluation of outdoor microclimate environmental performance in residential buildings in Lhasa.
Building-integrated photovoltaics (BIPVs) have been extensively studied in solar-rich regions, whereas the research in solar-poor regions remains limited, particularly regarding the combined assessment of economic and daylighting performance. This study investigated BIPV optimization for office buildings in solar-poor regions by jointly considering the net energy consumption (Enet), static payback period (SPP), and daylight autonomy (DA). Three representative building morphologies were identified through a cluster analysis. NSGA-II was used to generate Pareto-optimal solutions, and TOPSIS was applied to select representative compromise solutions using the building orientation (BO), window-to-wall ratio (WWR), photovoltaic transmittance (PVT), and photovoltaic coverage ratio (PVR) as the decision variables. The Pareto-optimal solutions were frequently concentrated at BO = 80–130°, WWR = 1.0, PVT = 30–40%, and PVR = 0.9–1.0. The PVR and PVT showed the strongest standardized associations with performance. Compared with the baseline cases, the representative solutions reduced the SPP by 8.34% and 11.94% for Types II and III, respectively, while Type I remained nearly unchanged. The DA increased by 4.58–15.46%. These results demonstrate morphology-dependent trade-offs and provide a transferable framework for BIPV façade optimization in solar-poor regions.