Merlin Carson

Mr. Merlin Carson

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MCMerlin Carson
Merlin Carson
WWWalt Woods
Walt Woods
SRSebastian Reynolds
Sebastian Reynolds
MWMark Wetzel
Mark Wetzel
AMAdam J. Morton
Adam J. Morton
CTChristof Teuscher
Christof Teuscher
Many radionuclide identification algorithms use statistical inference to collect a variety of features from gamma-ray spectra to deduce the presence of particular radionuclides. More modern algorithms require large amounts of data to learn and use latent features from spectra for classification. Both approaches are computationally expensive, which is reflected in their power consumption, and require large amounts of user intervention to prepare. In this paper we introduce a low power, neuromorphic algorithm for the real-time identification of radionuclides which simultaneously considers the entire shape of a gamma-ray spectrum. Utilizing the output of a traditional gamma-ray detector, our spiking, locally competitive algorithm uses sparse coding optimization to compare global patterns in a gamma-ray spectrum with a dictionary of radionuclide templates. This approach allows us to model informative global features resulting from both photoelectric absorption and Compton scattering. For the purpose of radiation threat reduction, the dictionary consists of data from the Nuclear Wallet Cards, a list of radionuclides and their properties compiled by the National Nuclear Data Center. To test our algorithm we use a variety of gamma-ray spectra created using radionuclides measured under laboratory conditions with varying durations, distances, activity levels, and backgrounds, resulting in a wide range of signal to noise ratios. We have created test sets for three different gamma-ray detector types, with 57Co, 137Cs, 152Eu, 60Co, 239Pu, and 235U sources, to quantify the effect of resolution, efficiency, and background on the accuracy of the algorithm. We demonstrate a true positive accuracy of 91% with a high resolution detector and 89% with a low resolution detector on the corresponding test sets. Experimenting with the same radionuclides included in the test sets in a variety of special nuclear material (SNM) masking configurations, we show that our algorithm is capable of correctly identify both SNM and mask even when the activity level of the mask is several times higher than that of the SNM. We also determine that our algorithm achieves over a 99% reduction in power consumption over other radionuclide identification software applications, which is critical for long term, independent monitoring and is the goal of this research.

27 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JCJorge I. Canales-Verdial
Jorge I. Canales-Verdial
JWJamison R. Wagner
Jamison R. Wagner
LSLandon Schmucker
Landon Schmucker
MWMark Wetzel
Mark Wetzel
PPPhilippe Proctor
Philippe Proctor
PZPayman Zarkesh-Ha
Payman Zarkesh-Ha
A comprehensive analysis and simulation of two memristor-based neuromorphic architectures for nuclear radiation detection is presented. Both scalable architectures retrofit a locally competitive algorithm to solve overcomplete sparse approximation problems by harnessing memristor crossbar execution of vector–matrix multiplications. The proposed systems demonstrate excellent accuracy and throughput while consuming minimal energy for radionuclide detection. To ensure that the simulation results of our proposed hardware are realistic, the memristor parameters are chosen from our own fabricated memristor devices. Based on these results, we conclude that memristor-based computing is the preeminent technology for a radiation detection platform.