Zhifan Teng

Dr. Zhifan Teng

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
QLQuanyue Liu
Quanyue Liu
RHRenjie Huang
Renjie Huang
ZTZhifan Teng
Zhifan Teng
LWLei Wang
Lei Wang
YWYaohui Wang
Yaohui Wang
Qiuliang WangQiuliang Wang
Qiuliang Wang
Due to the higher thermal stability and the ability to be operated at liquid-helium-free temperature, the HTS cable show great promise for conduction-cooled tokamak magnet applications. However, the YBCO tapes embedded within the slot produce an axial strain, leading to a degradation in critical current. Meantime, the critical current is also strongly influenced by the field and its incidence angle on the tape. Understanding the impact of the coupled electromagnetic-mechanical effect on critical current degradation and magnetization loss is paramount. In this study, the coupling mechanical-electromagnetic critical current estimation model was first built based on the longitudinal strain model and tape its own in-field property. Subsequently, we analyze the DC critical current and the dynamic magnetization loss based on the 2D T-A model. Through the integration of the non-uniform magnetic field and longitudinal strain, the distribution of the critical current density could be evaluated. This enabled the complex current distribution and magnetization loss to be monitored effectively. The results of this study will be employed in the further optimization of CICC conductor in the future.

9 October 2023 in Archive of Applied Mechanics
Verified
Journal Article
Closed access
PDF file
ZTZhifan Teng
Zhifan Teng
Jianhua LiuJianhua Liu
Jianhua Liu
HSHongbo Sun
Hongbo Sun
QLQuanyue Liu
Quanyue Liu
Yujia ZhaiYujia Zhai
Yujia Zhai
Qiuliang WangQiuliang Wang
Qiuliang Wang

28 October 2024 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
ZTZhifan Teng
Zhifan Teng
JRJixiong Ren
Jixiong Ren
Jianhua LiuJianhua Liu
Jianhua Liu
HSHongbo Sun
Hongbo Sun
Qiuliang WangQiuliang Wang
Qiuliang Wang
The magnetically controlled capsule endoscope (MCCE) is a user-friendly device widely used in intestine examinations; however, maintaining its flexible movement through the intestine is still challenging. In this paper, three different permanent magnet structures within the MCCE are evaluated. The magnetic forces and torques on the different permanent magnet structures in three dimensions are analyzed through finite element simulations. Experimental comparison of pressure, controllable degrees of freedom, and speed of movement of the MCCE with different permanent magnet structures on the intestine under static and dynamic conditions. The results showed that the MCCE with a combined permanent magnet structure performed well in shortening the examination time and reducing the pressure on the intestine. These studies provide a reference for the design of permanent magnets.

6 December 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ZTZhifan Teng
Zhifan Teng
Jianhua LiuJianhua Liu
Jianhua Liu
HSHongbo Sun
Hongbo Sun
YWYaohui Wang
Yaohui Wang
Yujia ZhaiYujia Zhai
Yujia Zhai
Qiuliang WangQiuliang Wang
Qiuliang Wang
The Capsule endoscope (CE) is widely used for intestinal examinations due to its non-invasive advantages. The external permanent magnet (EPM) is used as the motion control device of the CE, and the magnitude and distribution of the magnetic field strength and gradient generated by them affect the motion performance of the CE. To improve the motion performance of the CE in the intestinal tract, this study compares the relationship between the electromagnetic force and torque produced by the EPMs of spherical, cylindrical, and square structures on the internal permanent magnet (IPM) at different rotational angles and positions according to the driving strategy of the CE under the same conditions of the magnet volume by means of finite element simulation software. The results show that the cylindrical EPM can contribute best to the CE. Therefore, the EPM with a larger surface area and perimeter structure can provide a better contribution to the driving force of the CE under the same magnetization intensity.

24 February 2025 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
ZTZhifan Teng
Zhifan Teng
JRJixiong Ren
Jixiong Ren
Jianhua LiuJianhua Liu
Jianhua Liu
HSHongbo Sun
Hongbo Sun
QLQuanyue Liu
Quanyue Liu
Qiuliang WangQiuliang Wang
Qiuliang Wang
This article proposes a 3-D spatial rotational actuation strategy to improve the propulsion capability of the magnetically controlled capsule endoscope (MCCE) within the intestine. By establishing an actuation model for the MCCE within 3-D space, the critical range of actuation angles for effective propulsion and uniform forward motion of the MCCE has been calculated. Experiments have demonstrated that within the critical range of actuation angles, the MCCE can be effectively initiated and made to achieve a state of uniform motion. The results show that the displacements at different actuation angles exhibit 99% consistency with an average movement speed error of 4.3%. The experimental and simulation results validate the effectiveness of the proposed actuation strategy in 3-D space, providing theoretical and experimental evidence for the application of the MCCE in the intestinal environment.

14 February 2025 in The European Physical Journal Special Topics
Verified
Journal Article
Closed access
PDF file
TZTengfei Zhi
Tengfei Zhi
Jianhua LiuJianhua Liu
Jianhua Liu
YCYong Chen
Yong Chen
ZTZhifan Teng
Zhifan Teng
SLShixian Liu
Shixian Liu
Qiuliang WangQiuliang Wang
Qiuliang Wang