Farhad Moradi

Dr. Farhad Moradi


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2020 in IEEE Photonics Journal
Verified
Journal Article
Open access
HZH.T. Zubair
H.T. Zubair
MBMahfuza Begum
Mahfuza Begum
FMFarhad Moradi
Farhad Moradi
ARA. K. M. Mizanur Rahman
A. K. M. Mizanur Rahman
GMGhafour A. Mahdiraji
Ghafour A. Mahdiraji
DBDAVID BRADLEY
DAVID BRADLEY
In this paper, we review the highly promising silica glass, fabricated as doped and undoped optical fiber for intended use in radiation dosimetry. The dosimetry techniques reviewed here, underpinned by intrinsic and extrinsic defects in silica glass, focus on Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radioluminescence (RL), with occasional references to the much more established Radiation Induced Attenuation (RIA). The other focus in this review is on the various materials that have been reported earlier as dopants and modifiers used in silica glass optical fiber radiation dosimeters. This article also elaborates on recently reported optical fiber structures, namely, cylindrical fibers, photonic crystal fibers and flat fibers, as well as dimensions and shapes used for optimization of dosimeter performance. The various types of optical fiber radiation dosimeters are subsequently reviewed for various applications ranging from medical dosimetry such as in external beam radiotherapy, brachytherapy and diagnostic imaging, as well as in industrial processing and space dosimetry covering a dynamic dose range from μGy to kGy. Investigated dosimetric characteristics include reproducibility, fading, dose response, reciprocity between luminescence yield to dose-rate and energy dependence. The review is completed by a brief discussion on limitations and future developments in optical fiber radiation dosimetry.

28 July 2017 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
FMFarhad Moradi
Farhad Moradi
NUNgie Min Ung
Ngie Min Ung
Mayeen Uddin KhandakerMayeen Uddin Khandaker
Mayeen Uddin Khandaker
GMG A Mahdiraji
G A Mahdiraji
MSMarniza Saad
Marniza Saad
DBDavid A Bradley
David A Bradley
The relatively new treatment modality electronic intraoperative radiotherapy (IORT) is gaining popularity, irradiation being obtained within a surgically produced cavity being delivered via a low-energy x-ray source and spherical applicators, primarily for early stage breast cancer. Due to the spatially dramatic dose-rate fall off with radial distance from the source and effects related to changes in the beam quality of the low keV photon spectra, dosimetric account of the Intrabeam system is rather complex. Skin dose monitoring in IORT is important due to the high dose prescription per treatment fraction. In this study, modeling of the x-ray source and related applicators were performed using the Monte Carlo N-Particle transport code. The dosimetric characteristics of the model were validated against measured data obtained using an ionization chamber and EBT3 film as dosimeters. By using a simulated breast phantom, absorbed doses to the skin for different combinations of applicator size (1.5–5 cm) and treatment depth (0.5–3 cm) were calculated. Simulation results showed overdosing of the skin (>30% of prescribed dose) at a treatment depth of 0.5 cm using applicator sizes larger than 1.5 cm. Skin doses were significantly increased with applicator size, insofar as delivering 12 Gy (60% of the prescribed dose) to skin for the largest sized applicator (5 cm diameter) and treatment depth of 0.5 cm. It is concluded that the recommended 0.5–1 cm distance between the skin and applicator surface does not guarantee skin safety and skin dose is generally more significant in cases with the larger applicators. Highlights: • Intrabeam x-ray source and spherical applicators were simulated and skin dose was calculated. • Skin dose for constant skin to applicator distance strongly depends on applicator size. • Use of larger applicators generally results in higher skin dose. • The recommended 0.5–1 cm skin to applicator distance does not guarantee skin safety.

5 May 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AEA. Entezam
A. Entezam
Mayeen Uddin KhandakerMayeen Uddin Khandaker
Mayeen Uddin Khandaker
YAY. M. Amin
Y. M. Amin
NUN. M. Ung
N. M. Ung
DBD. A. Bradley
D. A. Bradley
FMFarhad Moradi
Farhad Moradi
Study has been made of the thermoluminescence (TL) response of silica-based Ge-doped cylindrical, flat and photonic crystal fibres (referred to herein as PCF-collapsed) to electron (6, 12 and 20 MeV) and photon (6, 10 MV) irradiation and 1.25 MeV γ-rays, for doses from 0.1 Gy to 100 Gy. The electron and photon irradiations were delivered through use of a Varian Model 2100C linear accelerator located at the University of Malaya Medical Centre and γ-rays delivered from a 60Co irradiator located at the Secondary Standard Dosimetry Laboratory (SSDL), Malaysian Nuclear Agency. Tailor-made to be of various dimensions and dopant concentrations (6–10% Ge), the fibres were observed to provide TL yield linear with radiation dose, reproducibility being within 1–5%, with insensitivity to energy and angular variation. The sensitivity dependency of both detectors with respect to field size follows the dependency of the output factors. For flat fibres exposed to 6 MV X-rays, the 6% Ge-doped fibre provided the greatest TL yield while PCF-collapsed showed a response 2.4 times greater than that of the 6% Ge-doped flat fibres. The response of cylindrical fibres increased with core size. The fibres offer uniform response, high spatial resolution and sensitivity, providing the basis of promising TL systems for radiotherapy applications.

1 July 2023 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
ATAli Taheri
Ali Taheri
MKMayeen Uddin Khandaker
Mayeen Uddin Khandaker
FMFarhad Moradi
Farhad Moradi
DBDAVID BRADLEY
DAVID BRADLEY

1 November 2017 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
FMFarhad Moradi
Farhad Moradi
Mayeen Uddin KhandakerMayeen Uddin Khandaker
Mayeen Uddin Khandaker
GMG.A. Mahdiraji
G.A. Mahdiraji
NUN.M. Ung
N.M. Ung
DBD.A. Bradley
D.A. Bradley

1 April 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
FMFarhad Moradi
Farhad Moradi
NUNgie Min Ung
Ngie Min Ung
GMG A Mahdiraji
G A Mahdiraji
Mayeen Uddin KhandakerMayeen Uddin Khandaker
Mayeen Uddin Khandaker
MSMee Hong See
Mee Hong See
DBDavid A Bradley
David A Bradley
Ge-doped silica fibre (GDSF) thermoluminescence dosimeters (TLD) are non-hygroscopic spatially high-resolution radiation sensors with demonstrated potential for radiotherapy dosimetry applications. The INTRABEAM ® system with spherical applicators, one of a number of recent electronic brachytherapy sources designed for intraoperative radiotherapy (IORT), presents a representative challenging dosimetry situation, with a low keV photon beam and a desired rapid dose-rate fall-off close-up to the applicator surface. In this study, using the INTRABEAM ® system, investigations were made into the potential application of GDSF TLDs for in vivo IORT dosimetry. The GDSFs were calibrated over the respective dose- and depth-range 1 to 20 Gy and 3 to 45 mm from the x-ray probe. The effect of different sizes of spherical applicator on TL response of the fibres was also investigated. The results show the GDSF TLDs to be applicable for IORT dose assessment, with the important incorporated correction for beam quality effects using different spherical applicator sizes. The total uncertainty in use of this type of GDSF for dosimetry has been found to range between 9.5% to 12.4%. Subsequent in vivo measurement of skin dose for three breast patients undergoing IORT were performed, the measured doses being below the tolerance level for acute radiation toxicity.