Sermin Onaygil

Prof. Sermin Onaygil

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 September 2003 in Lighting Research & Technology
Verified
Journal Article
Closed access
PDF file
ÖGÖ Güler
Ö Güler
Sermin OnaygilSermin Onaygil
Sermin Onaygil
This study evaluates the effect of low overall and longitudinal uniformities ratios on visual conditions as measured by visibility level at certain points of the road when the average visibility level on the road surface is adequate. A computer program has been developed to determine criteria for calculation of the road lighting based on visibility level to ensure driver comfort and safety. Five different arrangements, left hand single-sided, opposite, staggered, twin-bracket central and combined twin-bracket central and opposite are examined for 30 different road lighting luminaires. To examine the effect of the luminance uniformity on visibility level, average luminances of 1.0; 1.5; 2.0; 2.5 and 3.0 cd/m2 were obtained by changing the mounting height and luminaire spacing. This study explores the effect that luminance uniformity ratios and the luminaire type have on the visibility level. The uniformity ratios provided should not be lower than the values recommended for road lighting calculations based on the luminance concept. To obviate negative visual conditions, a criterion that restricts the distribution of the visibility level values on the road is needed in addition to the average visibility level and both overall and longitudinal luminance uniformity ratios.

1 January 2014 in Energy and Buildings
Verified
Journal Article
Closed access
MYM. Berker Yurtseven
M. Berker Yurtseven
EEEmre Erkin
Emre Erkin
EAEbru Acuner
Ebru Acuner
SMSeher Mete
Seher Mete
Sermin OnaygilSermin Onaygil
Sermin Onaygil

17 May 2017 in Lighting Research & Technology
Verified
Journal Article
Closed access
BBB Buyukkinaci
B Buyukkinaci
Sermin OnaygilSermin Onaygil
Sermin Onaygil
OGO Guler
O Guler
MYMb Yurtseven
Mb Yurtseven
This study investigates visibility levels for different road lighting scenarios. Four different road lighting classes (M2, M3, M4, M5), two different colour temperature luminaires (4000 K and 6000 K) and four different critical object reflectances (0.20, 0.30, 0.40, 0.50) were used to determine the effects of lighting classes and colour temperatures on the critical object detection. In total, 1920 photographs were taken on a test road and visibility levels were calculated for each case. From these 1920 visibility levels, photographs corresponding to 245 visibility level values ranging from 1 to 9 were selected and evaluated by 30 subjects aged between 25 and 35 years in a laboratory environment. As a result of the study, it was shown that visibility levels are between 7.0 and 8.5 for road lighting classes ranging from M2 to M5, illuminated by light sources with different colour temperatures, for 100% detection of critical objects. This result is in line with the suggested VL values changing between 7 and 10 in the literature.

1 February 2003 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
Sermin OnaygilSermin Onaygil
Sermin Onaygil
ÖGÖnder Güler
Önder Güler
EEEmre Erkin
Emre Erkin

28 March 2024 in Buildings
Verified
Journal Article
Open access
PDF file
sevda ALIPARASTsevda ALIPARAST
sevda ALIPARAST
Sermin OnaygilSermin Onaygil
Sermin Onaygil
In this field study, we examined the impact of human-centered lighting on an open-plan office environment, involving the participation of sixty office workers. The objective was to investigate the effects of the Circadian Stimulus (CS) and Equivalent Melanopic Lux (EML) metrics. This study took place at Istanbul Technical University in Istanbul, Turkey. The office was equipped with single Correlated Color Temperature (CCT) light emitting diode (LED) sources, featuring two different light beam distributions: Direct Suspended Linear (L1) and Direct and Indirect Suspended Linear (L2). To minimize energy consumption, we proposed simulations for a suspended individual lighting system. The office workers were invited to complete visual cognitive performance tests, proofreading tasks, and the Karolinska Sleepiness Scale (KSS) test to measure alertness. Additionally, participants were asked to provide feedback on the comfort criteria associated with the designed human-centered lighting concept. The preliminary findings from part 1 of this field study shed light on the potential of office lighting modifications in enhancing energy efficiency and meeting the standards set by WELL v2 2023 Q4 and UL Design Guideline 24480 (2019). Part 2 of this study will further optimize the proposed lighting quality concept to determine the most suitable individual lighting solution for office workers.