Gregory Ross

Mr. Gregory Ross


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
JBJenna A. Brown
Jenna A. Brown
MHMatthew Ross Harrison
Matthew Ross Harrison
TRTecle Rufael
Tecle Rufael
SRSelina A. Roman-White
Selina A. Roman-White
GRGregory Ross
Gregory Ross
DZDaniel Zimmerle
Daniel Zimmerle
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, building upon previous research in the field. The methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 69%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates at a majority of facilities and in aggregate across all facilities. The overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand the factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.

23 August 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
OKOlga Khaliukova
Olga Khaliukova
YZYuanrui Zhu
Yuanrui Zhu
WDWilliam Daniels
William Daniels
ARArvind Ravikumar
Arvind Ravikumar
GRGregory Ross
Gregory Ross
DHDorit Hammerling
Dorit Hammerling
Methane measurements at liquefied natural gas (LNG) facilities play an important role in characterizing methane emissions from the natural gas supply chain. The large size and complexity of LNG facilities make quantifying emissions with ground-based monitoring systems challenging, making aerial platforms one of the preferred methods for methane measurements at these sites. However, aerial measurements typically provide a snapshot of emissions at a given instance, necessitating further analytical steps to infer both annualized emissions and the range of possible emissions at different instants in time. This study uses aerial measurements at two LNG facilities from a Quantification, Monitoring, Reporting, and Verification project to characterize the distribution of temporally averaged emissions (i.e., annualized inventories) and possible site-level emissions at any given point in time (``instantaneous emissions''). The former provides uncertainty on the aerial measurement component of measurement-informed inventories representing annual averages, while the latter will help contextualize future snapshot measurements (e.g., aerial surveys or high-resolution satellite platforms) at LNG facilities. We find that instantaneous emissions may fall well outside of the distribution describing uncertainty in the annual inventory. We also compare different pre-analysis schemes for aerial data, as existing literature does not provide a clear consensus on methods for doing so, especially at LNG facilities.

12 October 2023 in ChemRxiv
Verified
Preprint
Open access
PDF file
JBJenna Brown
Jenna Brown
MHMatthew Ross Harrison
Matthew Ross Harrison
TRTecle Rufael
Tecle Rufael
SRSelina Roman-White
Selina Roman-White
GRGregory Ross
Gregory Ross
DZDaniel Zimmerle
Daniel Zimmerle
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, extending work done in Brown et al.1. Methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 68%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates, at a majority of facilities and in aggregate across all facilities. Overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods, on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting, fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.

25 May 2023 in ChemRxiv
Verified
Preprint
Open access
PDF file
JBJenna Brown
Jenna Brown
TRTecle Rufael
Tecle Rufael
MHMatthew Ross Harrison
Matthew Ross Harrison
SRSelina Roman-White
Selina Roman-White
GRGregory Ross
Gregory Ross
DZDaniel Zimmerle
Daniel Zimmerle
Increased interest in greenhouse gas (GHG) emissions, including recent legislative action and voluntary programs, has increased attention on quantifying, and ultimately reducing, methane emissions from the natural gas supply chain. While inventories used for public or corporate GHG policies have traditionally utilized bottom-up (BU) methods to estimate emissions, the validity of such inventories has been questioned. Therefore, there is attention on utilizing full-facility measurements using airborne, satellite or drone (top-down (TD)) techniques to inform, improve, or validate inventories. This study utilized full-facility estimates from two independent TD methods at 15 midstream natural gas facilities in the U.S.A., and were compared with a contemporaneous daily inventory assembled by the facility operator, employing comprehensive inventory methods. Estimates from the two TD methods statistically agreed in 2 of 28 paired measurements. Operator inventories, which included extensions to capture sources beyond regular inventory requirements and to integrate local measurements, estimated significantly lower emissions than the TD estimates for 40 of 43 paired comparisons. Significant disagreement is observed at most facilities, both between the two TD methods and between the TD estimates and operator inventory. These findings have two implications. Firstly, improving inventory estimates will require additional on-site or ground-based diagnostic screening and measurement of all sources. Secondly, the TD full-facility measurement methods need to undergo further testing, characterization, and potential improvement specifically tailored for complex midstream facilities.