Hasnaa Haidara

Dr. Hasnaa Haidara

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2025 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
HHHasnaa Haidara
Hasnaa Haidara
Eman Abdulrahman AssireyEman Abdulrahman Assirey
Eman Abdulrahman Assirey
TSTaoufiq Saffaj
Taoufiq Saffaj
BIBouchaib Ihssane
Bouchaib Ihssane
Background: Measurement uncertainty (MU) is a crucial parameter for ensuring the reliability of analytical methods and the validity of results, as required by ISO 17025:2017. Its estimation is particularly critical for quality control laboratories, where compliance decisions are based on a rigorous interpretation of uncertainties. Methods: In this study, we evaluated the uncertainty associated with an HPLC-UV method for the determination of Metopimazine (MPZ) in a pharmaceutical form, applying two complementary approaches: The ISO-GUM (Guide to the Expression of Uncertainty in Measurement) top-down approach and the Monte Carlo Simulation (MCS). Results: The results of both approaches showed excellent agreement, thus validating the robustness of the evaluation. The analysis of uncertainty sources revealed that the accuracy of the sample volume (VSample) and the calibration standard (Cx) were the dominant contributors, representing 39.9% and 36.2% of the total uncertainty, respectively. Combined, these two factors accounted for 76.1% of the variability, underscoring their critical impact on the assay’s precision. The expanded uncertainty (k = 2, 95% confidence level) was determined to be (99.41 ± 0.69)%, reflecting the method’s reproducibility. Conclusions: These results highlight the importance of rigorously controlling calibration standard preparation, sample volume, and repeatability conditions to optimize the reliability of the assay.

6 December 2022 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
HHHasnaa Haidara
Hasnaa Haidara
HBHouda Bouchafra
Houda Bouchafra
TSTaoufiq Saffaj
Taoufiq Saffaj
BIBouchaib Ihssane
Bouchaib Ihssane

21 April 2021 in Egyptian Journal of Chemistry
Verified
Journal Article
Closed access
HHHasnaa Haidara
Hasnaa Haidara
TSTaoufiq Saffaj
Taoufiq Saffaj
ABAbdeslem Bentama
Abdeslem Bentama
RHRidouane El Hajji
Ridouane El Hajji
BIBouchaib Ihssane
Bouchaib Ihssane
Measurement uncertainty, no doubt, is an important element in examining and interpreting the results obtained in chemical analyses, particularly in the pharmaceutical field. Obviously, this is required by several guides and standards; however, few documents are interested in estimating the measurement uncertainty associated with dissolution test results. In this paper, the Guide to the expression of Uncertainty in Measurement (GUM) and its Supplement 1 "Monte-Carlo Simulation" (MCS) were used, side by side, to estimate the measurement uncertainty of two dissolution test methods, each using a different instrumental technique, namely UV-Visible Spectrophotometry and High Performance Liquid Chromatography (HPLC). A comparative study of both approaches was successfully conducted then with the aim of not only examining the compatibility between the results of the two methods, but also the presentation and discussion of the advantages and limitations of the applicability of each approach in drug analyses. The results obtained with the ISO-GUM and the Monte-Carlo simulation, for the two cases of analysis, revealed comparability between the estimates of uncertainty. Indeed, the standard uncertainties obtained by the two approaches are very close (uGUM Repaglinide (RG) = 1.1885% & uMCM Repaglinide (RG) = 1.1854% and uGUM Irbesartan (IB) = 1.4028 % & uMCM Irbesartan (IB) = 1.3071%). On the other hand, it has been found that the ISO-GUM approach slightly overestimates the expanded uncertainty because of the used value k = 2 of the coverage factor. Moreover, we have found that the conditions of applicability of the analytical approach and its numerical complement are not always obvious, in particular, when the model of calculation of the measurand is complicated and the instruments of measurements used are complex.

15 October 2025 in Journal of Materials Research
Verified
Journal Article
Closed access
PDF file
ATAnass Tazi
Anass Tazi
ODOmar DAGDAG
Omar DAGDAG
MRMourad Rafik
Mourad Rafik
AAABDESLAM El Amri
ABDESLAM El Amri
MAMouna Azogagh
Mouna Azogagh
MRMohammed Rafik
Mohammed Rafik

11 June 2026 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
HBHamza Belmir
Hamza Belmir
HHHasnaa Haidara
Hasnaa Haidara
RARajae Aitlhaj
Rajae Aitlhaj
TSTaoufiq Saffaj
Taoufiq Saffaj
IBIHSSANE Chouaib Bouchaib
IHSSANE Chouaib Bouchaib
Background: Reliable measurement uncertainty estimation is essential for building trust in analytical results and ensuring they meet regulatory expectations. In HPLC chromatography, the chosen approach for uncertainty estimation can strongly influence both the results and their interpretation. Objective: This study compares two widely used strategies, the ISO-GUM method and Monte Carlo simulation applied with either single-point or multi-point calibration, for the simultaneous quantification of four statins at the National Laboratory for Drug Control (LNCM). Methods: In the single-point approach, all sources of uncertainty were combined into one global model, while the multi-point approach evaluated variability across different calibration levels. Both strategies were applied within the ISO-GUM framework and through Monte Carlo simulation, allowing a side-by-side comparison of the resulting uncertainty budgets. Results: The single-point method tended to underrepresent the variability present in actual measurements. In contrast, the multi-point method, especially when paired with Monte Carlo simulation, delivered uncertainty estimates that better reflected real-world analytical conditions. The ISO-GUM framework combined with multi-point calibration also proved to be a robust and practical option for routine use. Conclusions: Multi-point calibration, whether combined with Monte Carlo simulation or the ISO-GUM method, offers a more representative and reliable way to assess uncertainty in HPLC statin analysis.