Helga SZAMBOLICS

Dr. Helga SZAMBOLICS

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2010 in Physical Review B
Verified
Journal Article
Closed access
PDF file
FGFelipe Garcia
Felipe Garcia
HSHelga SZAMBOLICS
Helga SZAMBOLICS
AMA. P. Mihai
A. P. Mihai
LVL. Vila
L. Vila
AMA. Marty
A. Marty
LBL. D. Buda-Prejbeanu
L. D. Buda-Prejbeanu
In this work, we present a micromagnetic study of a magnetic domain wall dynamics influenced by magnetic fields and/or spin-polarized currents in systems characterized by perpendicular magnetization including crystalline defects. The dynamics in two different systems is studied: one showing the effect of defects in the flow regime, and the second one presenting the thermally activated depinning from a single defect. In the latter case, the thermal depinning can be analyzed within the framework of a single energy barrier process. In such situation, the current density can be assimilated to an applied field. We found that the energy barrier depends linearly on the applied field and on the injected current.

2 May 2024 in Materials
Verified
Journal Article
Open access
PDF file
STSimon Toinet
Simon Toinet
MBMohamed Benwadih
Mohamed Benwadih
HSHelga SZAMBOLICS
Helga SZAMBOLICS
CRChristine Revenant
Christine Revenant
DADavid Alincant
David Alincant
PCPierre-Jean COTTINET
Pierre-Jean COTTINET
To treat cardiovascular diseases (i.e., a major cause of mortality after cancers), endovascular-technique-based guidewire has been employed for intra-arterial navigation. To date, most commercially available guidewires (e.g., Terumo, Abbott, Cordis, etc.) are non-steerable, which is poorly suited to the human arterial system with numerous bifurcations and angulations. To reach a target artery, surgeons frequently opt for several tools (guidewires with different size integrated into angulated catheters) that might provoke arterial complications such as perforation or dissection. Steerable guidewires would, therefore, be of high interest to reduce surgical morbidity and mortality for patients as well as to simplify procedure for surgeons, thereby saving time and health costs. Regarding these reasons, our research involves the development of a smart steerable guidewire using electroactive polymer (EAP) capable of bending when subjected to an input voltage. The actuation performance of the developed device is assessed through the curvature behavior (i.e., the displacement and the angle of the bending) of a cantilever beam structure, consisting of single- or multi-stack EAP printed on a substrate. Compared to the single-stack architecture, the multi-stack gives rise to a significant increase in curvature, even when subjected to a moderate control voltage. As suggested by the design framework, the intrinsic physical properties (dielectric, electrical, and mechanical) of the EAP layer, together with the nature and thickness of all materials (EAP and substrate), do have strong effect on the bending response of the device. The analyses propose a comprehensive guideline to optimize the actuator performance based on an adequate selection of the relevant materials and geometric parameters. An analytical model together with a finite element model (FEM) are investigated to validate the experimental tests. Finally, the design guideline leads to an innovative structure (composed of a 10-stack active layer screen-printed on a thin substrate) capable of generating a large range of bending angle (up to 190°) under an acceptable input level of 550 V, which perfectly matches the standard of medical tools used for cardiovascular surgery.