Sean Schoeman

Dr. Sean Schoeman

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2023 in Pediatric Radiology
Verified
Journal Article
Open access
PDF file
ACAnith Chacko
Anith Chacko
SVShyam Sunder B Venkatakrishna
Shyam Sunder B Venkatakrishna
SSSean Schoeman
Sean Schoeman
SASavvas Andronikou
Savvas Andronikou
Effective communication of imaging findings in term hypoxic ischemic injury to family members, non-radiologist colleagues and members of the legal profession can be extremely challenging through text-based radiology reports. Utilization of three-dimensional (D) printed models, where the actual findings of the brain can be communicated via tactile perception, is a potential solution which has not yet been tested in practice. We aimed to determine the sensitivity and specificity of different groups, comprising trained radiologists, non-radiologist physicians and non-physicians, in the detection of gross disease of the cerebral cortex from 3-D printed brain models derived from magnetic resonance imaging (MRI) scans of children. Ten MRI scans in children of varying ages with either watershed pattern hypoxic ischemic injury (cortical injury) or basal-ganglia-thalamus hypoxic ischemic injury pattern with limited perirolandic cortical abnormalities and 2 normal MRI scans were post processed and 3-D printed. In total, 71 participants reviewed the 12 models and were required to indicate only the brain models that they felt were abnormal (with a moderate to high degree of degree of confidence). The 71 participants included in the study were 38 laypeople (54%), 17 radiographic technologists (24%), 6 nurses (8%), 5 general radiologists (7%), 4 non-radiologist physicians— 3 pediatricians and 1 neurologist (6%) and 1 emergency medical services staff (1%). The sensitivity and specificity for detecting the abnormal brains of the 71 participants were calculated. Radiologists showed the highest sensitivity (72%) and specificity (70%). Non-radiologist physicians had a sensitivity of 67.5% and a specificity of 75%. Nurses had a sensitivity of 70% and a specificity of 41.7%. Laypeople (non-medical trained) had a sensitivity of 56.1% and a specificity of 55.3%. Radiologists’ high sensitivity and specificity of 72% and 70%, respectively, validates the accuracy of the 3-D-printed models in reproducing abnormalities from MRI scans. The non-radiologist physicians also had a high sensitivity and specificity. Laypeople, without any prior training or guidance in looking at the models, had a sensitivity of 56.1% and a specificity of 55.3%. These results show the potential for use of the 3-D printed brains as an alternate form of communication for conveying the pathological findings of hypoxic ischemic injury of the brain to laypeople.

4 February 2025 in Pediatric Blood & Cancer
Verified
Journal Article
Closed access
SSSean Schoeman
Sean Schoeman
FEFernando Escobar
Fernando Escobar
PKPortia Kreiger
Portia Kreiger
SMSuzanne MacFarland
Suzanne MacFarland
PMPeter Mattei
Peter Mattei
MAMichael Acord
Michael Acord

25 September 2024 in Pediatric Pulmonology
Verified
Journal Article
Closed access
AZAntrea Zouvani
Antrea Zouvani
SVShyam Sunder B Venkatakrishna
Shyam Sunder B Venkatakrishna
SSSean Schoeman
Sean Schoeman
OSOnur Simsek
Onur Simsek
PBPravinkumar Bharde
Pravinkumar Bharde
SASavvas Andronikou
Savvas Andronikou

28 May 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
MMMaria Mezher
Maria Mezher
MEMohannad Elgamal
Mohannad Elgamal
SSSean Schoeman
Sean Schoeman
MAMaryam Alhasani
Maryam Alhasani
HOHansel Javier Otero
Hansel Javier Otero
Laith SultanLaith Sultan
Laith Sultan
Ultrasound is widely used in pediatric imaging because it is safe, portable, real-time, and free of ionizing radiation, but interpretation remains qualitative and operator-dependent. Ultrasound radiomics can extract quantitative features from standard grayscale images, providing potential biomarkers of tissue patterns not readily apparent on visual assessment. This structured narrative review summarizes pediatric ultrasound radiomics applications across organ systems and key barriers to clinical translation. Current evidence suggests promise in neonatal brain injury, neurodevelopmental assessment, liver disease staging, renal characterization, oncologic risk stratification, and emerging lung and muscle applications. However, most studies remain limited by retrospective single-center designs, small cohorts, acquisition variability, segmentation inconsistency, and limited external validation. Future progress will require standardized workflows, prospective multicenter validation, and clinically interpretable integration into decision-support systems.

13 June 2024 in Child's Nervous System
Verified
Journal Article
Closed access
PDF file
SVShyam Sunder B Venkatakrishna
Shyam Sunder B Venkatakrishna
EVEleana Vasileiadi
Eleana Vasileiadi
YNYouck Jen Siu Navarro
Youck Jen Siu Navarro
KVKaren L. Hanze Villavicencio
Karen L. Hanze Villavicencio
MSMonica Miranda Schaeubinger
Monica Miranda Schaeubinger
SASavvas Andronikou
Savvas Andronikou

12 April 2024 in Children
Verified
Journal Article
Open access
PDF file
SVShyam Sunder B Venkatakrishna
Shyam Sunder B Venkatakrishna
MTMarcelo S. Takahashi
Marcelo S. Takahashi
JCJuan S. Calle-Toro
Juan S. Calle-Toro
SSSean Schoeman
Sean Schoeman
JSJuan Sebastian Martin Saavedra
Juan Sebastian Martin Saavedra
SASavvas Andronikou
Savvas Andronikou
Purpose: We aimed to characterize the fetal buccal fat pad (BFP) on magnetic resonance imaging (MRI) to determine the frequency and types of sequences on which the BFP demonstrates low signal intensity and determine any possible correlation with timing of the MRI during fetal development. Materials and Methods: A retrospective review of all fetal MR studies was performed, and a pediatric radiologist blinded to the referring and final fetal diagnosis as well as outcome evaluated the included cases. A positive buccal fat pad sign (BFS) was recorded as present if a round, symmetric, and bilateral area was seen in the submalar region of the face with the following signal characteristics: T1 hyperintensity, low signal on echo planar imaging (EPI), low signal on true fast imaging with steady-state free precession (TRUFI), and with restriction on diffusion-weighted imaging (DWI). Results: A total of one hundred sixty-seven (167) fetal MRI studies: one hundred fourteen (114) body (68%) and fifty-three (53) neuro (32%) scans were reviewed during the study period. The BFS was most commonly seen on EPI (63%) and TRUFI (49%) sequences. Substantial agreement between TRUFI and EPI (κ = 0.68; p < 0.01); moderate agreement between TRUFI and T1 (κ = 0.53; p < 0.01) as well as T1 and EPI (κ = 0.53; p < 0.01), and fair agreement between EPI and Diffusion (κ = 0.28; p < 0.01) was observed. The median gestational age (GA) was 24 weeks (IQR 22–30 weeks). The fetuses with a positive BFS were significantly older (mean GA of 27 weeks or higher) than those without, for each sequence. Conclusions: The focal low signal in the fetal buccal fat pad, termed the fetal BFS, is a commonly encountered normal finding in the majority of fetal MRI scans on TRUFI and EPI sequences. This finding may be related to the presence and development of brown adipose tissue in the buccal fat pad resulting in T2* effects, but further studies are needed in order to confirm this. Further work can incorporate any of the sensitive sequences demonstrating low signal in brown adipose tissue to map its distribution and development in the fetus and beyond.