Tsung-Ting Shih

Prof. Dr. Tsung-Ting Shih

Department of Chemistry, Fu Jen Catholic University, Taipei, Taiwan
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

17 August 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Yu-Hao LinYu-Hao Lin
Yu-Hao Lin
WHWan-Tien Huang
Wan-Tien Huang
YHYi-Ting Huang
Yi-Ting Huang
YJYi-Ni Jhang
Yi-Ni Jhang
Tsung-Ting ShihTsung-Ting Shih
Tsung-Ting Shih
Ming-Jay DengMing-Jay Deng
Ming-Jay Deng
Flexible electrochemical supercapacitors (FESCs) are emerging as innovative energy storage systems, characterized by their stable performance, long cycle life, and portability/foldability. Crucial components of FESCs, such as electrodes and efficient electrolytes, have become the focus of extensive research. Herein, we examine deep eutectic solvent (DES)–based polymer gel systems for their cost-effective accessibility, simple synthesis, excellent biocompatibility, and exceptional thermal and electrochemical stability. We used a mixture a DES, LiClO4–2-Oxazolidinone as the electroactive species, and a polymer, either polyvinyl alcohol (PVA) or polyacrylamide (PAAM) as a redox additive/plasticizer. This combination facilitates a unique ion-transport process, enhancing the overall electrochemical performance of the polymer gel electrolyte. We manufactured and used LiClO4–2-Oxazolidinone (LO), polyvinyl alcohol–LiClO4–2-Oxazolidinone (PVA–LO), and polyacrylamide–LiClO4–2-Oxazolidinone (PAAM–LO) electrolytes to synthesize an MnO2 symmetric FESC. To evaluate their performance, we analyzed the MnO2 symmetric FESC using various electrolytes with cyclic voltammetry (CV), galvanostatic charge–discharge (GCD), and electrochemical impedance spectroscopy (EIS). The FESC featuring the PVA–LO electrolyte demonstrated superior electrochemical and mechanical performances. This solid-state MnO2 symmetric FESC exhibited a specific capacitance of 121.6 F/g within a potential window of 2.4 V. Due to the excellent ionic conductivity and the wide electrochemical operating voltage range of the PVA–LO electrolyte, a high energy density of 97.3 Wh/kg at 1200 W/kg, and a long-lasting energy storage system (89.7% capacitance retention after 5000 cycles of GCD at 2 A/g) are feasibly achieved. For practical applications, we employed the MnO2 symmetric FESCs with the PVA–LO electrolyte to power a digital watch and a light-emitting diode, further demonstrating their real-world utility.

21 August 2024 in Polymers
Verified
Journal Article
Open access
PDF file
JCJi-Hao Chen
Ji-Hao Chen
YLYu-Ting Luo
Yu-Ting Luo
YSYi-An Su
Yi-An Su
YKYan-Ren Ke
Yan-Ren Ke
Ming-Jay DengMing-Jay Deng
Ming-Jay Deng
Tsung-Ting ShihTsung-Ting Shih
Tsung-Ting Shih
Mercury (Hg) is a toxic element which impacts on biological systems and ecosystems. Because the toxicity of Hg species is highly dependent on their concentration levels and chemical forms, the sensitive identification of the chemical forms of Hg—i.e., Hg speciation—is of major significance in providing meaningful information about the sources of Hg exposure. In this study, a microfluidic-based device made of high-clarity poly(methyl methacrylate) (PMMA) was fabricated. Then, titanium dioxide nanoparticles (nano-TiO2s) were attached to the treated channel’s interior with the aid of poly(diallyldimethylammonium chloride) (PDADMAC). After coupling the nano-TiO2-coated microfluidic-based photocatalyst-assisted reduction device (the nano-TiO2-coated microfluidic-based PCARD) with high-performance liquid chromatography (HPLC) and inductively coupled plasma mass spectrometry (ICP-MS), a selective and sensitive, hyphenated system for Hg speciation was established. Validation procedures demonstrated that the method could be satisfactorily applied to the determination of mercury ions (Hg2+) and methylmercury ions (CH3Hg+) in both human urine and water samples. Remarkably, the zeta potential measured clearly indicated that the PDADMAC-capped nano-TiO2s with a predominance of positive charges indeed provided a steady force for firm attachment to the negatively charged device channel. The cause of the durability of the nano-TiO2-coated microfluidic-based PCARD was clarified thus.

23 March 2026 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
NMNaorem Jemes Jemes Meitei
Naorem Jemes Jemes Meitei
YCYu-Ting Chu
Yu-Ting Chu
CLChien-Hung Li
Chien-Hung Li
RMRahime Eshaghi Malekshah
Rahime Eshaghi Malekshah
WCWei-Min Ching
Wei-Min Ching
SHSodio C.N. Hsu
Sodio C.N. Hsu
β-Diketiminato Cu( ii )–nitrito complexes react with thiols ( t BuBzSH, BzSH, l -cysteine) to release NO and form a free ligand, disulfide, and an insoluble polymeric Cu( i )–thiolate (YP R ).

21 March 2024 in Journal of the Chinese Chemical Society
Verified
Journal Article
Closed access
PDF file
JCJi‐Hao Chen
Ji‐Hao Chen
CWChi‐Feng Weng
Chi‐Feng Weng
WWWei‐Chung Wang
Wei‐Chung Wang
YKYi‐Peng Kao
Yi‐Peng Kao
JTJia‐Lin Tsai
Jia‐Lin Tsai
Tsung-Ting ShihTsung-Ting Shih
Tsung-Ting Shih

15 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
JCJi-Hao Chen
Ji-Hao Chen
YLYu-Ting Luo
Yu-Ting Luo
YSYi-An Su
Yi-An Su
YKYan-Ren Ke
Yan-Ren Ke
Ming-Jay DengMing-Jay Deng
Ming-Jay Deng
Tsung-Ting ShihTsung-Ting Shih
Tsung-Ting Shih
Mercury (Hg) is a toxic element impacting on biological systems and ecosystems. Because the toxicity of Hg species is highly dependent on concentration levels and chemical forms, sensitive identification of chemical forms for Hg, i.e., Hg speciation, is of major significance in providing meaningful information about the source of Hg exposure. In this study, a microfluidic-based device made of high clarity poly(methyl methacrylate) (PMMA) was fabricated. Then titanium dioxide nanoparticles (nano-TiO2) were attached to the treated channel interior with the aid of poly(diallyldimethylammonium chloride) (PDADMAC). After coupling the nano-TiO2-coated microfluidic-based photocatalyst-assisted reduction device (the nano-TiO2-coated microfluid-ic-based PCARD) with high-performance liquid chromatography (HPLC) and inductively coupled plasma-mass spectrometry (ICP-MS), a selective and sensitive hyphenated system for Hg specia-tion was established. Validation procedures demonstrated that the method could be satisfactorily applied to the determination of mercuric ion (Hg2+) and methylmercury ion (CH3Hg+) in both human urine and water samples. Remarkably, the zeta potential measured clearly indicated the PDADMAC-capped nano-TiO2 with predominance of positive charges indeed provided steady force for firm attachment to the negatively charged device channel. The cause for the durability of the nano-TiO2-coated microfluidic-based PCARD was clarified thus.