Matthew Halquist

Dr. Matthew Halquist

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2020 in Expert Opinion on Drug Delivery
Verified
Journal Article
Closed access
VGVinit Gholap
Vinit Gholap
LKLeon Kosmider
Leon Kosmider
LGLaleh Golshahi
Laleh Golshahi
MHMatthew Halquist
Matthew Halquist
Unregulated e-cigarette devices and the levels of nicotine in them have amplified the potential of e-cigarettes as addictive agents. Several e-cigarette related parameters have been identified alte...

9 August 2018 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
VGVinit Gholap
Vinit Gholap
Leon KośmiderLeon Kośmider
Leon Kośmider
MHMatthew Halquist
Matthew Halquist
The use of electronic cigarettes (e-cigarettes) is a growing trend in population. E-cigarettes are evolving at a rapid rate with variety of battery powered devices and combustible nicotine refills such as e-liquids. In contrast to conventional cigarettes which are studied well for their toxicity and health effects, long-term clinical data on e-cigarettes are not available yet. Therefore, safety of e-cigarettes is still a major concern. Although the Food and Drug Administration (FDA) has recently started regulating e-cigarette products, no limits on nicotine and other ingredients in such products have been proposed. Considering the regulatory requirements, it is critical that reliable and standardized analytical methods for analyzing nicotine and other ingredients in e-cigarette products such as e-liquids are available. Here, we are reporting a fully validated high-performance liquid chromatography (HPLC) method based on nicotine peak purity for accurately quantifying nicotine in various e-liquids. The method has been validated as per ICH Q2(R1) and USP guidelines. The method is specific, precise, accurate, and linear to analyze nicotine in e-liquids with 1 to >50 mg/mL of nicotine. Additionally, the method has been proven robust and flexible for parameters such as change in flow rate, column oven temperature, and organic phase composition, which proves applicability of the method over wide variety of e-liquids in market.

10 March 2020 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
VGVinit Gholap
Vinit Gholap
RHRodrigo Heyder
Rodrigo Heyder
Leon KośmiderLeon Kośmider
Leon Kośmider
MHMatthew Halquist
Matthew Halquist
In electronic cigarette users, nicotine delivery to lungs depends on various factors. One of the important factors is e-liquid nicotine concentration. Nicotine concentration in e-liquids ranges from 0 to >50 mg/mL. Furthermore, nicotine exists in protonated and unprotonated (“free base”) forms. The two forms are believed to affect the nicotine absorption in body. Therefore, in addition to total nicotine concentration, e-liquids should be characterized for their free base nicotine yield. Two approaches are being used for the determination of free base nicotine in e-liquids. The first is applying a dilution to e-liquids followed by two methods: Henderson–Hasselbalch theory application or a Liquid-Liquid Extraction. The second is the without-dilution approach followed by 1H NMR method. Here, we carried out controlled experiments using five e-liquids of different flavors using these two approaches. In the dilution approach, the Henderson–Hasselbalch method was tested using potentiometric titration. The accuracy was found to be >98% for all five e-liquid samples (n = 3). A Liquid-Liquid Extraction was carried out using toluene or hexane as extraction solvent. The Liquid-Liquid Extraction technique was found to be limited by solvent interactions with flavors. Solvent extractions resulted in flavor dependent inaccuracies in free base nicotine determination (5 to 277% of calculated values). The without-dilution approach was carried out using 1H NMR as described by Duell et al. This approach is proposed to offer an independent and alternative scale. None of the methods have established a strong correlation between pre- and postvaporization free base nicotine yield. Here we present comparative results of two approaches using analytical techniques. Such a comparison would be helpful in establishing a standardized method for free base nicotine determination of e-liquids.


25 January 2011 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
KSKumar A. Shah
Kumar A. Shah
MPMichael C. Peoples
Michael C. Peoples
MHMatthew Halquist
Matthew Halquist
SRSarah C. Rutan
Sarah C. Rutan
HKH. Thomas Karnes
H. Thomas Karnes

24 June 2020 in Journal of Analytical Toxicology
Verified
Journal Article
Closed access
HMHaley A Mulder
Haley A Mulder
MHMatthew Halquist
Matthew Halquist
In the world of forensic and clinical toxicology, proper sample preparation is one of the key steps in identification and quantification of drugs of abuse. Traditional extraction methods such as solid-phase extraction and liquid−liquid extraction are often laborious and nonselective for the target analytes being measured. Molecularly imprinted polymers (MIPs) can be synthesized for sample extraction and their versatility allows the polymer to be employed in off-line, benchtop extractions or on/in-line instrument extractions, offering a faster and more selective sample preparation without the risk of interfering matrix effects. This review details the synthesis and applications of MIP materials for the extraction of drug compounds from biological matrices in publications from 1994 to today.