In this paper, a numerical model for the analysis of electromagnetic transients in a power system, based on the finite element technique, was developed. The simplicity of the finite element technique is manifested in the fact that the problem of solving any mathematically described phenomena in an area is reduced to solving those same phenomena in a small part of that area, i.e., finite elements. Based on appropriate mathematical models, numerical models of the synchronous generator and other parts of the power system have been developed. System of differential equations of each power system element have been included in the numerical model in such a way that we employ numerical integration of the differential equations using the generalized trapezoidal rule (-method) and reduce it to a system of algebraic equations in each time step. In a practical sense, this method enables a very simple solution to the problem of a real power system, i.e., a system with many generators, transformers, transmission lines and other elements. The accuracy of the developed numerical model for the analysis of electromagnetic transients in a power system has been confirmed by comparing the calculated results with the results obtained using the EMTP software (version 3.3) package.
Two types of grounding systems are recommended for use in the international standard IEC 62305-3, Part 3: Physical damage to structures and life hazard. One of these is a radial-based grounding system (type-A), which is used in soil resistivities of up to 3000 m and is considered in this paper. It is a well-known fact that during lightning strikes, only a part of the grounding wire contributes to dissipating the lightning current into the surrounding soil. This effective part of the grounding system depends on several features, such as soil resistivity, burial depth, and rise time of the dissipated lightning current. The effect of all of these features on the effective length of the type-A grounding system is explored in this paper. A suitable supervised machine learning regression model is developed, which will enable readers to accurately approximate the effective length of the type-A grounding system for realistic values of input features. The trained model in the paper yielded an value of 0.99998 on the test set. In addition, two simple mathematical formulas are also provided, which produce similar but less accurate results ( values of 0.989883 and 0.998557, respectively).
This article deals with an infinitesimal current source (ICS) in a multilayer conducting medium that consists of air and multilayer soil. Closed-form kernel functions of the spectral-domain Green's function for scalar electric and vector magnetic potentials (Lorentz potentials) were obtained for every layer of the multilayered medium as analytic solutions of the systems of linear equations. Validation of the proposed closed-form expressions is performed by numerical solving of the system of linear equations and by numerical comparison with expressions derived from existing closed-form expressions developed for the source layer of the multilayer dielectric medium. For an arbitrary-oriented ICS, scalar electric potential of its horizontal component is chosen as a unique scalar electric potential. Accordingly, dyadic Green's function of vector magnetic potential is corrected.
13 June 2022 in IEEE Transactions on Electromagnetic Compatibility