Marie Hanitriniaina RATSIMBA

Dr. Marie Hanitriniaina RATSIMBA


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Damien Ali Hamada FakraDamien Ali Hamada Fakra
Damien Ali Hamada Fakra
RRRijalalaina Rakotosaona
Rijalalaina Rakotosaona
MRMarie Hanitriniaina RATSIMBA
Marie Hanitriniaina RATSIMBA
RPRANDRIANARISON Mino Patricia
RANDRIANARISON Mino Patricia
Riad BenelmirRiad Benelmir
Riad Benelmir
African scientific research faces formidable challenges, particularly with limited access to state-of-the-art measurement instruments. The high cost associated with these devices presents a significant barrier for regional research laboratories, impeding their ability to conduct sophisticated experiments and gather precise data. This predicament not only hampers the individual laboratories but also has broader implications for the African scientific community and the advancement of knowledge in developing nations—the financial cost barrier considerably impacts the research quality of these laboratories. Reflection on technical and economical solutions needs to be quickly found to help these countries advance their research. In civil Engineering, the thermal conductivity property is the most important measurement for characterising heat transfer in construction materials. Existing devices (i.e., conductometers) in a laboratory are expensive (approximately 30,000 euros) and unavailable for some African laboratories. The study proposes a new and affordable device to evaluate thermal conductivity in construction materials. The method involves establishing a thermal flux between a heat source ( from the Joule effect provided by steel wool where a current is circulating) and a cold source (generated by ice cube) under steady-state conditions. The development of the cylindrical prototype is based on the comparative flux-meter method outlined in the measuring protocol of the ASTM E1225 standard document. Experiments were conducted on four distinct materials (polystyrene, wood, agglomerated wood, and rigid foam). The results indicate a correct correlation between the experimental values obtained from the newly developed prototype and the reference values found in the literature. For example, concerning the experimental polystyrene study, the detailed case analysis reveals a good correlation, with a deviation of only 4%. The percent error found falls within the acceptable range indicated by the standards recommendations of the ASTM E1225 standard, i.e., within 5% acceptable error.

30 August 2024 in Metrology
Verified
Journal Article
Open access
PDF file
Damien Ali Hamada FakraDamien Ali Hamada Fakra
Damien Ali Hamada Fakra
RRRijalalaina Rakotosaona
Rijalalaina Rakotosaona
MRMarie Hanitriniaina RATSIMBA
Marie Hanitriniaina RATSIMBA
RPRANDRIANARISON Mino Patricia
RANDRIANARISON Mino Patricia
Riad BenelmirRiad Benelmir
Riad Benelmir
African scientific research faces formidable challenges, particularly with limited access to state-of-the-art measurement instruments. The high cost associated with these devices presents a significant barrier for regional research laboratories, impeding their ability to conduct sophisticated experiments and gather precise data. This predicament not only hampers the individual laboratories but also has broader implications for the African scientific community and the advancement of knowledge in developing nations—the financial cost barrier considerably impacts the research quality of these laboratories. Reflection on technical and economical solutions needs to be quickly found to help these countries advance their research. In civil engineering, the thermal conductivity property is the most important measurement for characterizing heat transfer in construction materials. Existing devices (i.e., conductometers) in a laboratory are expensive (approximately EUR 30,000) and unavailable for some African laboratories. This study proposes a new and affordable device to evaluate thermal conductivity in construction materials. The method involves establishing a thermal flux between a heat source (from the Joule effect provided by steel wool where a current is circulating) and a cold source (generated by ice cubes) under steady-state conditions. The development of the cylindrical prototype is based on the comparative flux-meter method outlined in the measuring protocol of the ASTM E1225 standard document. Experiments were conducted on four distinct materials (polystyrene, wood, agglomerated wood, and rigid foam). The results indicate a correct correlation between the experimental values obtained from the newly developed prototype and the reference values found in the literature. For example, concerning the experimental polystyrene study, the detailed case analysis reveals a good correlation, with a deviation of only 4.88%. The percent error found falls within the acceptable range indicated by the standard recommendations of the ASTM E1225 standard, i.e., within 5% acceptable error.