Daniel Swetz

Dr. Daniel Swetz

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
WDW. Bertrand Doriese
W. Bertrand Doriese
PAP. Abbamonte
P. Abbamonte
BAB. K. Alpert
B. K. Alpert
DBD. A. Bennett
D. A. Bennett
EDE. V. Denison
E. V. Denison
DSDaniel Swetz
Daniel Swetz
We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.

7 August 2017 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JMJ. A. B. Mates
J. A. B. Mates
DBD. T. Becker
D. T. Becker
DBD. A. Bennett
D. A. Bennett
BDB. J. Dober
B. J. Dober
JGJ. D. Gard
J. D. Gard
JUJ. N. Ullom
J. N. Ullom
The number of elements in most cryogenic sensor arrays is limited by the technology available to multiplex signals from the arrays into a smaller number of wires and readout amplifiers. The largest demonstrated arrays of transition-edge sensor (TES) microcalorimeters contain roughly 250 detectors and use time-division multiplexing with Superconducting Quantum Interference Devices (SQUIDs). The bandwidth limits of this technology constrain the number of sensors per amplifier chain, a quantity known as the multiplexing factor, to several 10s. With microwave SQUID multiplexing, we can expand the readout bandwidth and enable much larger multiplexing factors. While microwave SQUID multiplexing of TES microcalorimeters has been previously demonstrated with small numbers of detectors, we now present a fully scalable demonstration in which 128 TES detectors are read out on a single pair of coaxial cables.

27 April 2023 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
TOT. Okumura
T. Okumura
TAT. Azuma
T. Azuma
DBD. A. Bennett
D. A. Bennett
ICI. Chiu
I. Chiu
WDW. Bertrand Doriese
W. Bertrand Doriese
SYS. Yamada
S. Yamada
To test bound-state quantum electrodynamics (BSQED) in the strong-field regime, we have performed high precision x-ray spectroscopy of the 5g–4f and 5f– 4d transitions (BSQED contribution of 2.4 and 5.2 eV, respectively) of muonic neon atoms in the low-pressure gas phase without bound electrons. Muonic atoms have been recently proposed as an alternative to few-electron high-Z ions for BSQED tests by focusing on circular Rydberg states where nuclear contributions are negligibly small. We determined the 5g9/2– 4f7/2 transition energy to be 6297.08±0.04(stat)±0.13(syst)  eV using superconducting transition-edge sensor microcalorimeters (5.2–5.5 eV FWHM resolution), which agrees well with the most advanced BSQED theoretical prediction of 6297.26 eV.

12 September 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
KMK. M. Morgan
K. M. Morgan
BABradley Alpert
Bradley Alpert
DBD. A. Bennett
D. A. Bennett
EDE. V. Denison
E. V. Denison
WDW. Bertrand Doriese
W. Bertrand Doriese
DSDaniel Swetz
Daniel Swetz
Code-division multiplexing (CDM) offers a path to reading out large arrays of transition edge sensor (TES) X-ray microcalorimeters with excellent energy and timing resolution. We demonstrate the readout of X-ray TESs with a 32-channel flux-summed code-division multiplexing circuit based on superconducting quantum interference device (SQUID) amplifiers. The best detector has energy resolution of 2.28 ± 0.12 eV FWHM at 5.9 keV and the array has mean energy resolution of 2.77 ± 0.02 eV over 30 working sensors. The readout channels are sampled sequentially at 160 ns/row, for an effective sampling rate of 5.12 μs/channel. The SQUID amplifiers have a measured flux noise of 0.17 μΦ0/√Hz (non-multiplexed, referred to the first stage SQUID). The multiplexed noise level and signal slew rate are sufficient to allow readout of more than 40 pixels per column, making CDM compatible with requirements outlined for future space missions. Additionally, because the modulated data from the 32 SQUID readout channels provide information on each X-ray event at the row rate, our CDM architecture allows determination of the arrival time of an X-ray event to within 275 ns FWHM with potential benefits in experiments that require detection of near-coincident events.

1 December 2019 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
PSPaul Szypryt
Paul Szypryt
GOGalen C O'Neil
Galen C O'Neil
ETE. Takacs
E. Takacs
JTJ. N. Tan
J. N. Tan
SBS. W. Buechele
S. W. Buechele
YRYuri Ralchenko
Yuri Ralchenko
We report on the design, commissioning, and initial measurements of a Transition-Edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at t

11 November 2019 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
JMJ. A. B. Mates
J. A. B. Mates
DBD. T. Becker
D. T. Becker
DBD. A. Bennett
D. A. Bennett
BDB. J. Dober
B. J. Dober
JGJ. D. Gard
J. D. Gard
JUJ. N. Ullom
J. N. Ullom
Low-temperature detector technologies provide extraordinary sensitivity for applications ranging from precision measurements of the cosmic microwave background to high-resolution, high-rate x-ray, and γ-ray spectroscopy. To utilize this sensitivity, new instruments are being built, and new instruments are imagined, with ever greater pixel counts, but the scale of these instruments is limited by the capability of the readout electronics. Microwave SQUID multiplexing addresses the needs of these future instruments, exploiting gigahertz of bandwidths of coaxial cables and broadband components to combine hundreds to thousands of signals on a single readout line. A key feature of any multiplexer is the level of crosstalk between input channels. This crosstalk can degrade the sensitivity of the instrument, introduce systematic error, or simply confound data analysis. In this letter, we explain the primary mechanisms of crosstalk in a microwave SQUID multiplexer, calculate and measure their magnitude, and consider their effect and methods of mitigation.