Kaylyn Leung

Dr. Kaylyn Leung

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2021 in ACS Sensors
Verified
Journal Article
Closed access
KLKaylyn Leung
Kaylyn Leung
ADAlex M. Downs
Alex M. Downs
GOGabriel Ortega
Gabriel Ortega
MKMartin Kurnik
Martin Kurnik
KPKevin Plaxco
Kevin Plaxco

19 May 2023 in Science Advances
Verified
Journal Article
Open access
JGJulian Gerson
Julian Gerson
MEMurat Kaan Erdal
Murat Kaan Erdal
MMMatthew H. McDonough
Matthew H. McDonough
KPKyle L. Ploense
Kyle L. Ploense
PDPhilippe Dauphin-Ducharme
Philippe Dauphin-Ducharme
TKTod Kippin
Tod Kippin
Knowledge of drug concentrations in the brains of behaving subjects remains constrained on a number of dimensions, including poor temporal resolution and lack of real-time data. Here, however, we demonstrate the ability of electrochemical aptamer-based sensors to support seconds-resolved, real-time measurements of drug concentrations in the brains of freely moving rats. Specifically, using such sensors, we achieve 1.5 hours. These results demonstrate the utility of such sensors in (i) the determination of the site-specific, seconds-resolved neuropharmacokinetics, (ii) enabling the study of individual subject neuropharmacokinetics and concentration-response relations, and (iii) performing high-precision control over intracranial drug levels.

2 November 2023 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
EVElsi Verrinder
Elsi Verrinder
KLKaylyn Leung
Kaylyn Leung
MEMurat Kaan Erdal
Murat Kaan Erdal
LSLior Sepunaru
Lior Sepunaru
KPKevin Plaxco
Kevin Plaxco
Electrochemical aptamer-based sensors support real-time, in vivo molecular measurements. Here we compare the relative merits of square-wave, alternating current, and differential pulse voltammetry in the interrogation of such sensors.

16 August 2023 in ACS Sensors
Verified
Journal Article
Open access
BRBrian Roehrich
Brian Roehrich
KLKaylyn Leung
Kaylyn Leung
JGJulian Gerson
Julian Gerson
TKTod E. Kippin
Tod E. Kippin
KPKevin W. Plaxco
Kevin W. Plaxco
LSLior Sepunaru
Lior Sepunaru
Electrochemical aptamer-based (EAB) sensors are capable of measuring the concentrations of specific molecules in vivo, in real time, and with a few-second time resolution. For their signal transduction mechanism, these sensors utilize a binding-induced conformational change in their target-recognizing, redox-reporter-modified aptamer to alter the rate of electron transfer between the reporter and the supporting electrode. While a variety of voltammetric techniques have been used to monitor this change in kinetics, they suffer from various drawbacks, including time resolution limited to several seconds and sensor-to-sensor variation that requires calibration to remove. Here, however, we show that the use of fast Fourier transform electrochemical impedance spectroscopy (FFT-EIS) to interrogate EAB sensors leads to improved (here better than 2 s) time resolution and calibration-free operation, even when such sensors are deployed in vivo. To showcase these benefits, we demonstrate the approach's ability to perform real-time molecular measurements in the veins of living rats.

14 May 2024 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
JCJulia Chung
Julia Chung
ABAdriana Billante
Adriana Billante
CFCharlotte Flatebo
Charlotte Flatebo
KLKaylyn Leung
Kaylyn Leung
JGJulian Gerson
Julian Gerson
KPKevin Plaxco
Kevin Plaxco
The electrochemical aptamer-based (EAB) sensor platform is the only molecular monitoring approach yet reported that is (1) real time and effectively continuous, (2) selective enough to deploy in situ in the living body, and (3) independent of the chemical or enzymatic reactivity of its target, rendering it adaptable to a wide range of analytes. These attributes suggest the EAB platform will prove to be an important tool in both biomedical research and clinical practice. To advance this possibility, here we have explored the stability of EAB sensors upon storage, using retention of the target recognizing aptamer, the sensor's signal gain, and the affinity of the aptamer as our performance metrics. Doing so we find that low-temperature (−20 °C) storage is sufficient to preserve sensor functionality for at least six months without the need for exogenous preservatives.

1 July 2025 in ACS Sensors
Verified
Journal Article
Closed access
JPJoshua D. Pham
Joshua D. Pham
LFLisa Fetter
Lisa Fetter
JGJulian Gerson
Julian Gerson
TKTod E. Kippin
Tod E. Kippin
KPKevin Plaxco
Kevin Plaxco
KLKaylyn Leung
Kaylyn Leung