We compared the detection rate (DR) for sentinel lymph nodes (SLNS), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus. The literature search was updated until December 31st, 2019. DR was calculated on a per-patient-based analysis; the studies were pooled by their odds ratios (ORs) with a random effects model to assess the significance of difference (p < 0.05). The number of additional SLNs (calculated as the relative risk) and pooled proportion of patients with additional SLNs were investigated. The pooled ratio of surgical procedures influenced by the SPECT/CT findings was calculated. Seventeen studies with 1438 patients were eligible for the calculation of DR of SPECT/CT and PL. The average DR was 98.28% (95% confidence interval (95% CI): 97.94–99.19%) for the SPECT/CT and 95.53% (95% CI: 92.55–97.77%) for the PL; OR of 2.31 (95% CI: 1.66–4.18, p < 0.001) in favor of the SPECT/CT. There was a relative risk of a higher number of SLNs (1.13) for the SPECT/CT and 17.87% of patients with additional SLNs were detected by SPECT/CT. The average impact of SPECT/CT on surgery resulted in 37.43% of cases. This meta-analysis favored SPECT/CT over PL for the identification of SLNs in patients with melanoma due to a higher DR, reproducibility, number of SLNs depicted, proportion of patients with additional SLNs and the impact on the surgical plan. However, PL remains a good option due to the high values of the DR for SLNs.
Purpose: The clinical introduction of a radioactive and fluorescent hybrid tracer allowed for preoperative lymphatic mapping and intraoperative real-time fluorescence tracing of the sentinel lymph node (SLN) by a single injection. The aim of this feasibility study is to evaluate the first-in-human use of the hybrid tracer by combining indocyanine green (ICG) and radiocolloid based on Nanotop compound (99mTc Nanotop) for SLN biopsy (SLNB) in breast cancer patients. Methods: The day before surgery, ICG-99mTc Nanotop was injected periareolarly in breast cancer patients scheduled for SLNB. Planar lymphoscintigraphic (PL) and SPECT/CT images were then acquired. An intraoperative optonuclear probe was used to detect SLN gamma and fluorescent signals. The harvested SLNs were examined by hematoxylin-eosin staining, and patients were clinically evaluated 1 month after surgery. Results: Twenty-one consecutive patients were enrolled. The PL and SPECT/CT techniques identified at least 1 SLN in all patients for a preoperative sentinel detection rate of 100%. SPECT/CT revealed 3 additional lymph nodes in the same nodal basin, which had not been visualized on conventional PL (κ = 0.747; P < 0.005). All 30 preoperative SLNs were localized and excised up to 16 hours after injection. The counts measured via gamma tracing showed a very strong correlation with those measured via near-infrared fluorescent tracing (P < 0.005, r = 0.964). No adverse reactions were observed. Conclusions: The SLNB technique used with the ICG-99mTc Nanotop tracer resulted to be feasible, reliable, and safe. This hybrid compound allowed us to obtain excellent performance in terms of both preoperative lymphatic mapping and intraoperative SLN detection in breast cancer patients.
26 July 2019 in Clinical and Translational Imaging
Lymphadenectomy represents a fundamental step in the staging and treatment of non-small cell lung cancer (NSCLC). To date, the extension of lymphadenectomy in early-stage NSCLC is a debated topic due to its possible complications. The detection of sentinel lymph nodes (SLNs) is a strategy that can improve the selection of patients in which a more extended lymphadenectomy is necessary. This pilot study aimed to refine lymph nodal staging in early-stage NSCLC patients who underwent robotic lung resection through the application of innovative intraoperative sentinel lymph node (SLN) identification and the pathological evaluation using one-step nucleic acid amplification (OSNA). Clinical N0 NSCLC patients planning to undergo robotic lung resection were selected. The day before surgery, all patients underwent radionuclide computed tomography (CT)-guided marking of the primary lung lesion and subsequently Single Photon Emission Computed Tomography (SPECT) to identify tracer migration and, consequently, the area with higher radioactivity. On the day of surgery, the lymph nodal radioactivity was detected intraoperatively using a gamma camera. SLN was defined as the lymph node with the highest numerical value of radioactivity. The OSNA amplification, detecting the mRNA of CK19, was used for the detection of nodal metastases in the lymph nodes, including SLN. From March to July 2021, a total of 8 patients (3 female; 5 male), with a mean age of 66 years (range 48–77), were enrolled in the study. No complications relating to the CT-guided marking or preoperative SPECT were found. An average of 5.3 lymph nodal stations were examined (range 2–8). N2 positivity was found in 3 out of 8 patients (37.5%). Consequently, pathological examination of lymph nodes with OSNA resulted in three upstages from the clinical IB stage to pathological IIIA stage. Moreover, in 1 patient (18%) with nodal upstaging, a positive node was intraoperatively identified as SLN. Comparing this protocol to the usual practice, no difference was found in terms of the operating time, conversion rate, and complication rate. Our preliminary experience suggests that sentinel lymph node detection, in association with the accurate pathological staging of cN0 patients achieved using OSNA, is safe and effective in the identification of metastasis, which is usually undetected by standard diagnostic methods.
29 March 2023 in Clinical and Translational Imaging