Joelle B Texereau

Dr. Joelle B Texereau

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
PJPhilippe Jolliet
Philippe Jolliet
LOLamia Ouanes-Besbes
Lamia Ouanes-Besbes
FAFekri Abroug
Fekri Abroug
JKJalila Ben Khelil
Jalila Ben Khelil
MBMohamed Besbes
Mohamed Besbes
OEOn Behalf Of The E.C.H.O.Icu
On Behalf Of The E.C.H.O.Icu
Rationale: During noninvasive ventilation (NIV) for chronic obstructive pulmonary disease (COPD) exacerbations, helium/oxygen (heliox) reduces the work of breathing and hypercapnia more than air/O2, but its impact on clinical outcomes remains unknown. Objectives: To determine whether continuous administration of heliox for 72 hours, during and in-between NIV sessions, was superior to air/O2 in reducing NIV failure (25–15%) in severe hypercapnic COPD exacerbations. Methods: This was a prospective, randomized, open-label trial in 16 intensive care units (ICUs) and 6 countries. Inclusion criteria were COPD exacerbations with PaCO2 ≥ 45 mm Hg, pH ≤ 7.35, and at least one of the following: respiratory rate ≥ 25/min, PaO2 ≤ 50 mm Hg, and oxygen saturation (arterial [SaO2] or measured by pulse oximetry [SpO2]) ≤ 90%. A 6-month follow-up was performed. Measurements and Main Results: The primary endpoint was NIV failure (intubation or death without intubation in the ICU). The secondary endpoints were physiological parameters, duration of ventilation, duration of ICU and hospital stay, 6-month recurrence, and rehospitalization rates. The trial was stopped prematurely (445 randomized patients) because of a low global failure rate (NIV failure: air/O2 14.5% [n = 32]; heliox 14.7% [n = 33]; P = 0.97, and time to NIV failure: heliox group 93 hours [n = 33], air/O2 group 52 hours [n = 32]; P = 0.12). Respiratory rate, pH, PaCO2, and encephalopathy score improved significantly faster with heliox. ICU stay was comparable between the groups. In patients intubated after NIV failed, patients on heliox had a shorter ventilation duration (7.4 ± 7.6 d vs. 13.6 ± 12.6 d; P = 0.02) and a shorter ICU stay (15.8 ± 10.9 d vs. 26.7 ± 21.0 d; P = 0.01). No difference was observed in ICU and 6-month mortality. Conclusions: Heliox improves respiratory acidosis, encephalopathy, and the respiratory rate more quickly than air/O2 but does not prevent NIV failure. Overall, the rate of NIV failure was low. Clinical trial registered with www.clinicaltrials.gov (NCT 01155310).

27 February 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Damien LEGERDamien LEGER
Damien LEGER
MEMAXIME ELBAZ
MAXIME ELBAZ
BPBenoît Piednoir
Benoît Piednoir
ACAmélie Carron
Amélie Carron
JTJoelle B Texereau
Joelle B Texereau
Optimizing the measurement of Continuous Positive Airway Pressure (CPAP) compliance and treatment efficacy is paramount for patients with obstructive sleep apnea syndrome (OSAS). Compliance knowledge is currently based on data coming from CPAP machines; however algorithms and measured parameters vary from one machine to another. This study was conducted to clinically evaluate a novel device, NOWAPI®, designed to assess compliance remotely in conjunction with any CPAP machine. NOWAPI® was tested against polygraphy, the gold standard for the measurement of CPAP treatment duration and residual apnea-hypopnea index (AHI). Single group assignment, open label, non-randomized. Sleep laboratory setting. 22 adult patients with OSAS treated by CPAP were included. Recordings were performed during one night while the patient was treated with his/her usual CPAP and interface. NOWAPI® data were collected electronically and compared to data acquisition and visual scoring using an EMBLETTA® GOLD polygraph. Statistics were only descriptive. Recordings were performed with six different CPAP machines and three different interfaces (full facemask, nasal pillow, nasal mask). The median [Q1; Q3] absolute difference in CPAP treatment duration between NOWAPI® and polygraphy was of 1.0 min [0.0; 12.0], corresponding to a relative difference of 0.21 % [0.0; 2.2] (Per Protocol data set, n = 20). NOWAPI® tended to underestimate residual AHI in a magnitude of two events per hour as compared to polygraphy. The device was well tolerated and the patient satisfaction was good. This clinical study confirmed prior bench tests, showing that NOWAPI® estimate of CPAP treatment duration was clinically acceptable and in agreement with polygraphy. Although a limited number of OSAS patients treated by CPAP were included, relevant findings for the device improvement were identified. Trial Registration ClinicalTrials.gov identifier: NCT01441622. The study was funded by Air Liquide HealthCare

3 October 2012 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
AMAndrew R Martin
Andrew R Martin
IKIra M Katz
Ira M Katz
KJKatharina Jenöfi
Katharina Jenöfi
GCGeorges Caillibotte
Georges Caillibotte
LBLaurent Brochard
Laurent Brochard
JTJoelle B Texereau
Joelle B Texereau
Inhalation of helium-oxygen (He/O2) mixtures has been explored as a means to lower the work of breathing of patients with obstructive lung disease. Non-invasive ventilation (NIV) with positive pressure support is also used for this purpose. The bench experiments presented herein were conducted in order to compare simulated patient inspiratory effort breathing He/O2 with that breathing medical air, with or without pressure support, across a range of adult, obstructive disease patterns.

1 January 2012 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
AMAndrew R Martin
Andrew R Martin
IKIra M Katz
Ira M Katz
KTKarine Terzibachi
Karine Terzibachi
LGLaure Gouinaud
Laure Gouinaud
GCGeorges Caillibotte
Georges Caillibotte
JTJoelle B Texereau
Joelle B Texereau
Expiratory time constants are used to quantify emptying of the lung as a whole, and emptying of individual lung compartments. Breathing low-density helium/oxygen mixtures may modify regional time constants so as to redistribute ventilation, potentially reducing gas trapping and hyperinflation for patients with obstructive lung disease. In the present work, bench and mathematical models of the lung were used to study the influence of heterogeneous patterns of obstruction on compartmental and whole-lung time constants. A two-compartment mechanical test lung was used with the resistance in one compartment held constant, and a series of increasing resistances placed in the opposite compartment. Measurements were made over a range of lung compliances during ventilation with air or with a 78/22% mixture of helium/oxygen. The resistance imposed by the breathing circuit was assessed for both gases. Experimental results were compared with predictions of a mathematical model applied to the test lung and breathing circuit. In addition, compartmental and whole-lung time constants were compared with those reported by the ventilator. Time constants were greater for larger minute ventilation, and were reduced by substituting helium/oxygen in place of air. Notably, where time constants were long due to high lung compliance (i.e. low elasticity), helium/oxygen improved expiratory flow even for a low level of resistance representative of healthy, adult airways. In such circumstances, the resistance imposed by the external breathing circuit was significant. Mathematical predictions were in agreement with experimental results. Time constants reported by the ventilator were well-correlated with those determined for the whole-lung and for the low-resistance compartment, but poorly correlated with time constants determined for the high-resistance compartment. It was concluded that breathing a low-density gas mixture, such as helium/oxygen, can improve expiratory flow from an obstructed lung compartment, but that such improvements will not necessarily affect time constants measured by the ventilator. Further research is required to determine if alternative measurements made at the ventilator level are predictive of regional changes in ventilation. It is anticipated that such efforts will be aided by continued development of mathematical models to include pertinent physiological and pathophysiological phenomena that are difficult to reproduce in mechanical test systems.

4 October 2024 in BMJ Open
Verified
Journal Article
Open access
PDF file
RMRaphael Le Mao
Raphael Le Mao
CGChristophe Gut Gobert
Christophe Gut Gobert
JTJoelle B Texereau
Joelle B Texereau
FKFrédérique Kremer
Frédérique Kremer
MGMarion Goret
Marion Goret
FGFrederic Gagnadoux
Frederic Gagnadoux
Objectives Telemonitoring (TM) of home non-invasive ventilation (NIV) has been shown to facilitate home/outpatient therapy set-up. However, the impact of long-term TM on therapy dropouts, compliance and leak control has not yet been clearly determined. This study evaluated whether the NIV dropout rate was reduced by TM combined with remote patient support compared with a non-telemonitoring (NTM) pathway. Design Retrospective cohort study. Setting Data were obtained from all agencies of a single home care provider in France. Participants Adults with chronic respiratory failure (n=659) who started nocturnal NIV between January 2017 and December 2019 and had ≥8 days of NIV therapy (51% male; mean age 68.5±13.8 years; 35.5% on long-term oxygen therapy) were included. The TM group included 275 patients who spent ≥80% of the follow-up using TM, and the NTM group included 384 patients who had 0 to ≤10 days of telemonitoring during follow-up. Primary and secondary outcome measures The primary outcome was the rate of NIV dropouts at 1 year (ie, treatment discontinuation, excluding deaths). Secondary outcomes included therapy compliance and leaks. Results 82 patients died during follow-up. Significantly fewer patients in the TM vs NTM group had dropped out of NIV therapy at 1 year (13% vs 34%; p<0.001). After adjustment for age, sex, NIV usage at 1-month follow-up and the main underlying respiratory disease, TM was significantly associated with a lower risk of dropout (HR 0.33, 95% CI 0.23 to 0.49; p4 hours/day and control of leaks. Conclusions In patients starting home NIV, TM with home care provider first-line support was associated with a lower therapy dropout rate at 1 year, and better compliance and leak control, compared with standard follow-up.

1 January 2012 in Medical Gas Research
Verified
Journal Article
Open access
PDF file
AMAndrew R Martin
Andrew R Martin
IKIra M Katz
Ira M Katz
YLYonatan Lipsitz
Yonatan Lipsitz
KTKarine Terzibachi
Karine Terzibachi
GCGeorges Caillibotte
Georges Caillibotte
JTJoelle B Texereau
Joelle B Texereau
Inhalation of low-density helium/oxygen mixtures has been used both to lower the airway resistance and work of breathing of patients with obstructive lung disease and to transport pharmaceutical aerosols to obstructed lung regions. However, recent clinical investigations have highlighted the potential for entrainment of room air to dilute helium/oxygen mixtures delivered through non-rebreather facemasks, thereby increasing the density of the inhaled gas mixture and limiting intended therapeutic effects. This article describes the development of benchtop methods using face models for evaluating delivery of helium/oxygen mixtures through facemasks.