Henar Alonso

Dr. Henar Alonso

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in PLOS Pathogens
Verified
Journal Article
Open access
PDF file
DPDelphine Payros
Delphine Payros
HAHenar Alonso
Henar Alonso
WMWladimir Malaga
Wladimir Malaga
AVArnaud Volle
Arnaud Volle
SMSerge Mazères
Serge Mazères
CGChristophe Guilhot
Christophe Guilhot
Mycobacterium tuberculosis, the main causative agent of human tuberculosis, is transmitted from person to person via small droplets containing very few bacteria. Optimizing the chance to seed in the lungs is therefore a major adaptation to favor survival and dissemination in the human population. Here we used TnSeq to identify genes important for the early events leading to bacterial seeding in the lungs. Beside several genes encoding known virulence factors, we found three new candidates not previously described: rv0180c, rv1779c and rv1592c. We focused on the gene, rv0180c, of unknown function. First, we found that deletion of rv0180c in M. tuberculosis substantially reduced the initiation of infection in the lungs of mice. Next, we established that Rv0180c enhances entry into macrophages through the use of complement-receptor 3 (CR3), a major phagocytic receptor for M. tuberculosis. Silencing CR3 or blocking the CR3 lectin site abolished the difference in entry between the wild-type parental strain and the Δrv0180c::km mutant. However, we detected no difference in the production of both CR3-known carbohydrate ligands (glucan, arabinomannan, mannan), CR3-modulating lipids (phthiocerol dimycocerosate), or proteins in the capsule of the Δrv0180c::km mutant in comparison to the wild-type or complemented strains. By contrast, we established that Rv0180c contributes to the functionality of the bacterial cell envelope regarding resistance to toxic molecule attack and cell shape. This alteration of bacterial shape could impair the engagement of membrane receptors that M. tuberculosis uses to invade host cells, and open a new perspective on the modulation of bacterial infectivity.

Verified
Journal Article
Open access
PDF file
MPMaría Paz Peris
María Paz Peris
BDBlanca Dehesa
Blanca Dehesa
HAHenar Alonso
Henar Alonso
CECristina Escolar
Cristina Escolar
LCLaura Clusa
Laura Clusa
ABAna Milagro Beamonte
Ana Milagro Beamonte
The capacity of Mycoplasma genitalium to develop resistance to macrolides makes detection of macrolide resistance genes by rapid real-time PCR assays increasingly necessary in clinical diagnostic laboratories so as to initiate appropriate treatment as rapidly as possible. The aim of this retrospective and comparative study was to conduct the clinical evaluation of three commercially available kits for macrolide resistance detection. A total of 111 M. genitalium positive samples analyzed in the Clinical Microbiology Laboratory of the Miguel Servet University Hospital, Zaragoza (Spain) were used. After M. genitalium molecular confirmation, the three assays under study were evaluated and discrepant results were resolved via sequencing. The clinical sensitivity for resistance detection was 83% (95% confidence interval, 69% to 93%) for the ResistancePlus® MG panel kit (SpeeDx Pty Ltd., Sydney, Australia), 95% (84% to 99%) for AllplexTM MG & AziR Assay (Seegene®, Seoul, Korea), and 97% (88% to 99%) for the VIASURE macrolide resistance-associated mutations (23SrRNA) Real time PCR detection kit (Certest Biotec, Zaragoza, Spain). The clinical specificity was 100% (94% to 100%) for Allplex and VIASURE assays and 95% (86% to 99%) for SpeeDx assay. The results arising from this study are cause for strong consideration for the implementation of rapid real-time PCR assays in clinical diagnosis laboratories to eliminate treatment failure and transmission as soon as possible.

30 April 2023 in Viruses
Verified
Journal Article
Open access
PDF file
SASonia Algarate
Sonia Algarate
JBJessica Bueno
Jessica Bueno
MCMaría J. Crusells
María J. Crusells
MAMariano Ara
Mariano Ara
HAHenar Alonso
Henar Alonso
RBRafael Benito
Rafael Benito
Cases of mpox have been reported in several European countries, including Spain. Our objective was to evaluate the usefulness of serum and nasopharyngeal samples for diagnosis of mpox. The presence of MPXV DNA was studied using real-time PCR (CerTest Biotec, Zaragoza, Spain) in 106 samples from 50 patients: 32 skin, 31 anogenital, 25 sera, and 18 nasopharyngeal/pharyngeal, in the Hospital Clínico Universitario of Zaragoza (Spain). Sixty-three samples from twenty-seven patients were MPXV PCR-positive. The real-time PCR Ct values in the anogenital and skin samples were lower than serum and nasopharyngeal samples. More than 90% of anogenital (95.7%), serum (94.4%), and skin (92.9%) samples were real-time PCR-positive. Eighteen (66.7%) of the twenty-seven patients who were MPXV PCR-positive had antecedents or presented with one to three sexually transmitted infection (STI) agents. Our results indicate that the use of serum samples can help facilitate the diagnosis of MPXV infections.

28 October 2024 in Antibiotics
Verified
Journal Article
Open access
PDF file
MPMaría Paz Peris
María Paz Peris
HAHenar Alonso
Henar Alonso
CECristina Escolar
Cristina Escolar
ABAlexander Tristancho Baró
Alexander Tristancho Baró
MAMaría Pilar Abad
María Pilar Abad
ABAna Milagro Beamonte
Ana Milagro Beamonte
Background and Objectives: Neisseria gonorrhoeae and Chlamydia trachomatis can cause similar clinical syndromes and may coexist in infections. In emergency medicine, empirical treatment targeting both pathogens is often employed, potentially contributing to antibiotic resistance. Gonococcal resistance has emerged against first-line antimicrobials, necessitating prior testing for fluoroquinolone susceptibility. Certest Biotec developed two molecular diagnostic products for simultaneous detection: VIASURE C. trachomatis & N. gonorrhoeae Real-Time PCR Detection Kit and VIASURE Neisseria gonorrhoeae Ciprofloxacin-Resistant Real-Time PCR Detection Kit. To evaluate these products, clinical performance assessments were conducted at the Clinical Microbiology Laboratory of Miguel Servet University Hospital in Zaragoza, Spain. Results and Conclusions: Both VIASURE assays under study demonstrated high clinical sensitivity and specificity compared to reference molecular assays and Sanger sequencing. These kits offer an accurate diagnosis, facilitating appropriate treatment choices while addressing concerns about emerging antibiotic resistance. Methods: A total of 540 clinical samples from 540 patients already characterized as positive or negative for CT and NG by a molecular assay and by antibiotic susceptibility testing for ciprofloxacin using a concentration gradient diffusion method were used for the clinical evaluation. In cases where sensitivity results were unavailable, conventional PCR and Sanger sequencing were employed.

1 February 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
ADAlejandro Dashti
Alejandro Dashti
HAHenar Alonso
Henar Alonso
CECristina Escolar
Cristina Escolar
PKPamela C. Köster
Pamela C. Köster
BBBegoña Bailo
Begoña Bailo
David González-BarrioDavid González-Barrio
David González-Barrio
Cryptosporidium spp., Giardia duodenalis and Entamoeba histolytica are species of protozoa- causing diarrhoea that are common worldwide, while Entamoeba dispar, Dientamoeba fragilis and Blastocystis sp. appear to be commensal parasites whose role in pathogenicity remains controversial. We conducted the clinical evaluation of five singleplex and one duplex CerTest VIASURE Real-Time PCR Assays against a large panel of positive DNA samples (n = 358), and specifically to Cryptosporidium spp. (n = 96), G. duodenalis (n = 115), E. histolytica (n = 25) E. dispar (n = 11), Blastocystis sp. (n = 42), D. fragilis (n = 37), and related parasitic phylum species such as Apicomplexa, Euglenozoa, Microsporidia and Nematoda. DNA samples were obtained from clinical stool specimens or cultured isolates in a national reference centre. Estimated diagnostic sensitivity and specificity values were 0.94–1 for Cryptosporidium spp., 0.96–0.99 for G. duodenalis, 0.96–1 for E. histolytica, 1–1 for E. dispar, and 1–0.99 for D. fragilis in the evaluated singleplex assays. In the duplex assay for the simultaneous detection of Blastocystis sp. and D. fragilis these values were 1–0.98 and 1–0.99, respectively. Measures of diagnostic precision for repeatability and reproducibility were found to be under acceptable ranges. The assays identified six Cryptosporidium species (C. hominis, C. parvum, C. canis, C. felis, C. scrofarum, and C. ryanae), four G. duodenalis assemblages (A, B, C, and F), and six Blastocystis subtypes (ST1-ST5, and ST8). The evaluated singleplex and duplex VIASURE Real-Time PCR assays provide sensitive, practical, and cost-effective choices to the molecular diagnosis of the main diarrhoea-causing intestinal protists in clinical microbiology and research laboratories.

14 October 2023 in Educación Médica
Verified
Journal Article
Open access
JMJorge Madera
Jorge Madera
APAna Pérez-Lozana
Ana Pérez-Lozana
HAHenar Alonso
Henar Alonso
JPJulio Pascual
Julio Pascual