Qing-quan Li

Dr. Qing-quan Li

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in High Voltage
Verified
Journal Article
Open access
PDF file
HZHongru Zhang
Hongru Zhang
JSJiaxiang Sun
Jiaxiang Sun
KHKaining Hou
Kaining Hou
QLQing-quan Li
Qing-quan Li
Hongshun LiuHongshun Liu
Hongshun Liu
A combined model based on improved information entropy and vague support vector machine (IVSVM) is introduced into transformer fault diagnosis using dissolved gas analysis in oil (DGA). The improved information entropy method is used to obtain the weights of each gas and to weight the raw data, and the processed training data and the corresponding fault types are inputted into the vague support vector machine (VSVM) model to obtain classifiers. Firstly, the training data are weighted by the improved information entropy method to discretise the original data from the mixed state for subsequent classifier training. Then, the vague set divides the events into true, false and unknown factors, which can optimise the sub‐interface of SVM and improve the accuracy of the boundary point classification. Finally, fault data from the literature and actual collections are selected for training and testing. By comparing with the widely used ratio method and artificial intelligence method, it can be concluded that the method described herein can effectively improve the accuracy of fault diagnosis. The result shows that this method has better applicability when facing actual fault type classification with higher data similarity.

27 October 2020 in High Voltage
Verified
Journal Article
Open access
PDF file
DHDongxin He
Dongxin He
TZTao Zhang
Tao Zhang
FMFansong Meng
Fansong Meng
QLQing-quan Li
Qing-quan Li
WWWei Wang
Wei Wang
GTGilbert Teyssedre
Gilbert Teyssedre
When high‐voltage direct current (HVDC) cables are subjected to a direct current(DC)‐superimposed pulsed electric stress, the pulsed voltage applied facilitates electrical tree generation and breakdown; however, the mechanism involved remains unclear. To study the deterioration mechanism of cable insulation under a pulsed electric field, an experiment on the dynamic characteristics of space charge under a DC‐superimposed pulsed electric field was conducted. For this experiment, a pulsed time trigger control circuit was developed to accurately measure the change law of the space charge in cross‐linked polyethylene samples at the rising and falling edges of the pulsed electric field. The experimental results showed an unusual change law: the space charge density increases with falling voltage amplitude and decreases with rising voltage amplitude. The sudden change in the electric field breaks the balance of the forces acting on the space charge, leading to injection, extraction and migration. The energy released during these dynamic processes may destroy the microstructure of the insulation material and contributes to the growth of the electrical tree. This study provides an insight on the initiation mechanism of electrical tree in HVDC cables and proposes a strategy to suppress electrical tree initiation.

7 August 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
HXHuaishuo Xiao
Huaishuo Xiao
JWJianchun Wei
Jianchun Wei
Hongshun LiuHongshun Liu
Hongshun Liu
QLQing-quan Li
Qing-quan Li
YSYalin Shi
Yalin Shi
TZTongqiao Zhang
Tongqiao Zhang
An improved variational mode decomposition (VMD) method is introduced into the mode recognition of low‐frequency oscillation of power system in this study. First, fast Fourier transform is used to determine the number of VMD components, and the approximate fitting formula of the best balancing parameter α is obtained by a large number of tests. The original signal is decomposed into several modes via improved VMD (IMVD) method. Then, Teager–Kaiser energy operator is applied on the fitting of each component to get the amplitude, frequency, and damping factor of it. By the constructed test signals, the proposed method is compared with the methods of non‐parametric VMD, empirical mode decomposition, total least‐squares estimation of signal parameters via rotational invariance techniques, and Prony on the performance of mode parameter identification. Results show that the IVMD method effectively overcomes the shortcomings of those methods mentioned above in dealing with mode mixing, noise sequence, and non‐stationary signals. Finally, the feasibility of the proposed method in extracting the low‐frequency oscillation mode parameters of power system is verified by the simulation signals of the IEEE two‐area four‐generator power system and the New England 39‐bus system.

1 March 2019 in Optik
Verified
Journal Article
Closed access
WSWen Si
Wen Si
BQBingyang Qin
Bingyang Qin
QLQing-quan Li
Qing-quan Li
HLHongshun Liu
Hongshun Liu

25 July 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
ZZZhongyu Zhao
Zhongyu Zhao
冠王冠 王
冠 王
Hongshun LiuHongshun Liu
Hongshun Liu
JYJingjing Yang
Jingjing Yang
HWHongbin Wu
Hongbin Wu
QLQing-quan Li
Qing-quan Li
Transformer oil and insulation paper are subject to the combined effects of the electric field and temperature operations, which significantly impact insulation deterioration. This article designs a comparative test of the electro-thermal combined aging to obtain several characteristic parameters for the aging degree of oil-pressboard insulation. Molecular dynamics are used to establish a mixed molecular model of oil-pressboard insulation to simulate the pyrolysis reactions at high temperatures using the ReaxFF force field. The microscopic effects of the electric field on the aging of oil-pressboard insulation are studied. The rationale of the simulation model is verified from experimental results, and the trend of the reactants and products in the reaction process was considered to determine the influence mechanism of electric–thermal coupling on oil-pressboard insulation. The experimental results show that thermal stress remains the most important factor toward cracking in insulation paper. The acid value and furfural formation rate in oil increase, and the polymerization degree of the insulation paper decreases rapidly after the combined electric and thermal aging. In addition, the molecular dynamics simulations show that pyrolysis increases the bond energy, promotes repulsion between atoms, and leads to fractured bonds. The addition of the electric field increases the susceptibility of the chemical bonds in cellulose molecules to breakage. The morphology of the cellulose chain then changes, and the diffusion of small molecules intensifies. This study reveals the mechanism of insulation aging under electro-thermal coupling through combined macroscopic testing and molecular dynamics simulations.

1 December 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
JSJiaxiang Sun
Jiaxiang Sun
DHDongxin He
Dongxin He
QLQing-quan Li
Qing-quan Li
HZHongru Zhang
Hongru Zhang
Hongshun LiuHongshun Liu
Hongshun Liu
Composite insulators, which use high temperature vulcanized (HTV) silicone rubber as shed material, are widely applied in transmission lines. Ice accumulation on their surfaces may inflict flashover accident and even massive power outage. In this study, a superhydrophobic (SH) coating on HTV silicone rubber was fabricated by the sol–gel process combined with the plasma jet treatment method. It was found that the as-prepared SH coating exhibited prominent superhydrophobicity and an excellent self-cleaning property with a water contact angle of 160.15°, a contact angle hysteresis of 0.60°, a sliding angle of 1.8°, and a surface free energy of 0.1421 mN/m. The anti-icing behavior of water droplets on the as-prepared SH coating surface was investigated at a low temperature of −30 °C and compared with that of the HTV silicone rubber surface. The results indicated that the freezing time on the SH coating was postponed obviously and was as long as 150 s. The SH coating surface exhibited about 5.6 times delay in freezing at −30 °C compared with the HTV silicone rubber surface. Furthermore, heterogeneous nucleation theory and heat transfer theory were introduced to explain the difference in freezing time between the as-prepared SH coating and HTV silicone rubber. It could be concluded that the SH coating had a large nucleation free energy barrier and a low heat transfer rate between the droplet and the surface and, thus, was able to effectively delay the freezing time.