Udo Piontek

Mr. Udo Piontek


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Li HuangLi Huang
Li Huang
UPUdo Piontek
Udo Piontek
The cold-chain transportation is an important means to ensure the drug and food safety. An cold-chain insulated container incorporating with Phase Change Material (PCM) has been developed for a temperature-controlled transportation in the range of 2~8 °C. The container configuration and different preconditioning methods have been determined to realize a 72-h transportation under extremely high, extremely low, and alternating temperature conditions. The experimental results showed that the temperature-controlled time was extended from 1 h to more than 80 h and the internal temperature maintained at 4~5 °C by using a PCM with a melting/freezing point of 5 °C, while the container presented a subcooling effect in a range of −1~2 °C when using water as PCM. The experimental values of the temperature-controlled time agreed well with the theoretical values.

14 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
Li HuangLi Huang
Li Huang
Rongyue ZhengRongyue Zheng
Rongyue Zheng
UPUdo Piontek
Udo Piontek
A solar cooling and heating system incorporated with two air-source heat pumps was installed in Ningbo City, China and has been operating since 2018. It is composed of 40 evacuated tube modules with a total aperture area of 120 m2, a single-stage and LiBr–water-based absorption chiller with a cooling capacity of 35 kW, a cooling tower, a hot water storage tank, a buffer tank, and two air-source heat pumps, each with a rated cooling capacity of 23.8 kW and heating capacity of 33 kW as the auxiliary system. This paper presents the operational results and performance evaluation of the system during the summer cooling and winter heatingperiod, as well as on a typical summer day in 2018. It was found that the collector field yield and cooling energy yield increased by more than 40% when the solar cooling and heating system is incorporated with heat pumps. The annual average collector efficiency was 44% for cooling and 42% for heating, and the average coefficient of performance (COP) of the absorption chiller ranged between 0.68 and 0.76. The annual average solar fraction reached 56.6% for cooling and 62.5% for heating respectively. The yearly electricity savings accounted for 41.1% of the total electricity consumption for building cooling and heating.

16 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
Li HuangLi Huang
Li Huang
UPUdo Piontek
Udo Piontek
LZLulu Zhuang
Lulu Zhuang
Rongyue ZhengRongyue Zheng
Rongyue Zheng
DZDeqiu Zou
Deqiu Zou
An electric radiator combined with salt hydrate-phase change material (PCM) storage was developed to replace the existing scattered coal burning systems for clean heating applications. It was designed to have an average heat output of 400 W and a thermal storage efficiency of 65.6% for reducing the electricity peak load. The thermal performance was investigated experimentally and numerically by using various radiator configurations and electric heating powers, as well as three PCMs with a melting point of 58 °C (PCMI 58), 78 °C (PCMI 78) and 90 °C (PCMI 90). It was found that the radiator combined with PCMI 78 had an average heat output of 412 W, and the PCMI 78 could be completely charged within 8 off-peak hours at an electric heating power of 1270 W, in the case of the radiator external dimension L × B × H of 796 × 106 × 656 mm and the L/B ratio of 7.5. The experiment results indicated that the average room temperature could be maintained at 20.0 °C at an outdoor temperature of 5.2 °C when applying the electric radiator developed.