Matteo Montorfano

Prof. Matteo Montorfano

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2020 in Circulation
Verified
Journal Article
Closed access
PDF file
GSGiulio G Stefanini
Giulio G Stefanini
MMMatteo Montorfano
Matteo Montorfano
Daniela TrabattoniDaniela Trabattoni
Daniela Trabattoni
DADaniele Andreini
Daniele Andreini
GFGiuseppe Ferrante
Giuseppe Ferrante
ACAlaide Chieffo
Alaide Chieffo

1 August 2002 in JACC
Verified
Journal Article
Closed access
Carlo BriguoriCarlo Briguori
Carlo Briguori
CSCristiano Sarais
Cristiano Sarais
PPPaolo Pagnotta
Paolo Pagnotta
FLFrancesco Liistro
Francesco Liistro
MMMatteo Montorfano
Matteo Montorfano
ACAntonio Colombo
Antonio Colombo

27 June 2020 in European Heart Journal
Verified
Journal Article
Open access
PDF file
SBSabine Bleiziffer
Sabine Bleiziffer
MSMatheus Simonato
Matheus Simonato
JWJohn G Webb
John G Webb
JRJosep Rodés-Cabau
Josep Rodés-Cabau
PPPhilippe Pibarot
Philippe Pibarot
DDDanny Dvir
Danny Dvir
Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2–12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02–1.13)], age [HR 1.21 (95% CI 1.01–1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11–1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis–patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31–14.39)], device malposition [SHR 3.75 (95% CI 1.36–10.35)], EBEV [SHR 3.34 (95% CI 1.26–8.85)], and age [SHR 0.59 (95% CI 0.44–0.78)]. The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.

19 July 2023 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
MPMatteo Pagnesi
Matteo Pagnesi
WKWon-Keun Kim
Won-Keun Kim
SBSara Baggio
Sara Baggio
Andrea ScottiAndrea Scotti
Andrea Scotti
MBMarco Barbanti
Marco Barbanti
AMAntonio Mangieri
Antonio Mangieri

18 June 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
FSFlorian Schlotter
Florian Schlotter
KHKurt Huber
Kurt Huber
CHChristian Hassager
Christian Hassager
SHSigrun Halvorsen
Sigrun Halvorsen
PVPascal Vranckx
Pascal Vranckx
HTHolger Thiele
Holger Thiele
Ventricular septal defects are a rare complication after acute myocardial infarction with a mortality close to 100% if left untreated. However, even surgical or interventional closure is associated with a very high mortality and currently no randomized controlled trials are available addressing the optimal treatment strategy of this disease. This state-of-the-art review and clinical consensus statement will outline the diagnosis, hemodynamic consequences and treatment strategies of ventricular septal defects complicating acute myocardial infarction with a focus on current available evidence and a focus on major research questions to fill the gap in evidence.

1 March 2022 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
MWMirjam G. Wild
Mirjam G. Wild
ELEdith Lubos
Edith Lubos
ICIgnacio Cruz-Gonzalez
Ignacio Cruz-Gonzalez
IAIgnacio Amat-Santos
Ignacio Amat-Santos
MAMarco Ancona
Marco Ancona
FPFabien Praz
Fabien Praz
Background: Patients with severe tricuspid regurgitation present late and are often ineligible for surgery or transcatheter repair systems. Transfemoral venous implantation of a bicaval valved stent has been proposed as therapeutic option in selected patients. The aim of this study was to summarize the early procedural and clinical outcomes of the novel TRICENTO system for the treatment of patients with symptomatic severe tricuspid regurgitation. Methods: All consecutive patients treated with the custom-made TRICENTO implant at the participating centers were included in this retrospective multicentre registry. Results: A total of 21 high-risk patients (mean age 76±7 years; 67% female) with severe or higher grade tricuspid regurgitation were analyzed. The majority of the patients were in New York Heart Association class III/IV (95%), had peripheral edema (95%), and previous hospitalization for right heart failure (67%). Technical success was 100%, and there was no case of in-hospital mortality. During follow-up (median 61 days), symptomatic improvement was observed (65% in New York Heart Association class I/II; P <0.001). Computed tomography revealed asymptomatic fractures of the TRICENTO prosthesis in 3 patients. Cardiac magnetic resonance imaging obtained in 7 patients showed a significant decrease (252±65 mm 3 at baseline versus 216±58 mm 3 at follow-up, P =0.006) of right ventricular end-diastolic volume. The overall-survival rate was 76% at 1 year. Conclusions: The present data indicate the feasibility of transfemoral bicaval valved stent implantation for the treatment of severe tricuspid regurgitation. Functional improvement and signs of right ventricular reverse remodeling were observed. Stent fractures did not impair valve function, but require refinement of prosthesis design and careful assessment of eligibility criteria.