Strahinja Stojadinovic

Dr. Strahinja Stojadinovic

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Yan LiuYan Liu
Yan Liu
SSStrahinja Stojadinovic
Strahinja Stojadinovic
BHBrian Hrycushko
Brian Hrycushko
ZWZabi Wardak
Zabi Wardak
SLSteven Lau
Steven Lau
XGXuejun Gu
Xuejun Gu
Accurate and automatic brain metastases target delineation is a key step for efficient and effective stereotactic radiosurgery (SRS) treatment planning. In this work, we developed a deep learning convolutional neural network (CNN) algorithm for segmenting brain metastases on contrast-enhanced T1-weighted magnetic resonance imaging (MRI) datasets. We integrated the CNN-based algorithm into an automatic brain metastases segmentation workflow and validated on both Multimodal Brain Tumor Image Segmentation challenge (BRATS) data and clinical patients' data. Validation on BRATS data yielded average DICE coefficients (DCs) of 0.75±0.07 in the tumor core and 0.81±0.04 in the enhancing tumor, which outperformed most techniques in the 2015 BRATS challenge. Segmentation results of patient cases showed an average of DCs 0.67±0.03 and achieved an area under the receiver operating characteristic curve of 0.98±0.01. The developed automatic segmentation strategy surpasses current benchmark levels and offers a promising tool for SRS treatment planning for multiple brain metastases.

1 December 2013 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
MDMarc Desrosiers
Marc Desrosiers
LDLarry DeWerd
Larry DeWerd
JDJames Deye
James Deye
PLPatricia Lindsay
Patricia Lindsay
MMMark K. Murphy
Mark K. Murphy
HSHelen Stone
Helen Stone
Radiation dose is central to much of radiobiological research. Precision and accuracy of dose measurements and reporting of the measurement details should be sufficient to allow the work to be interpreted and repeated and to allow valid comparisons to be made, both in the same laboratory and by other laboratories. Despite this, a careful reading of published manuscripts suggests that measurement and reporting of radiation dosimetry and setup for radiobiology research is frequently inadequate, thus undermining the reliability and reproducibility of the findings. To address these problems and propose a course of action, the National Cancer Institute (NCI), the National Institute of Allergy and Infectious Diseases (NIAID), and the National Institute of Standards and Technology (NIST) brought together representatives of the radiobiology and radiation physics communities in a workshop in September, 2011. The workshop participants arrived at a number of specific recommendations as enumerated in this paper and they expressed the desirability of creating dosimetry standard operating procedures (SOPs) for cell culture and for small and large animal experiments. It was also felt that these SOPs would be most useful if they are made widely available through mechanism(s) such as the web, where they can provide guidance to both radiobiologists and radiation physicists, be cited in publications, and be updated as the field and needs evolve. Other broad areas covered were the need for continuing education through tutorials at national conferences, and for journals to establish standards for reporting dosimetry. This workshop did not address issues of dosimetry for studies involving radiation focused at the sub-cellular level, internally-administered radionuclides, biodosimetry based on biological markers of radiation exposure, or dose reconstruction for epidemiological studies.

27 June 2013 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
RHRami R. Hallac
Rami R. Hallac
HZHeling Zhou
Heling Zhou
RPRajesh Pidikiti
Rajesh Pidikiti
KSKwang Song
Kwang Song
SSStrahinja Stojadinovic
Strahinja Stojadinovic
Ralph MasonRalph Mason
Ralph Mason
Purpose To examine the potential use of blood oxygenation level dependent (BOLD) and tissue oxygenation level dependent (TOLD) contrast MRI to assess tumor oxygenation and predict radiation response. Methods BOLD and TOLD MRI were performed on Dunning R3327‐AT1 rat prostate tumors during hyperoxic gas breathing challenge at 4.7 T. Animals were divided into two groups. In Group 1 (n = 9), subsequent 19F MRI based on spin lattice relaxation of hexafluorobenzene reporter molecule provided quantitative oximetry for comparison. For Group 2 rats (n = 13) growth delay following a single dose of 30 Gy was compared with preirradiation BOLD and TOLD assessments. Results Oxygen (100%O2) and carbogen (95%O2/5%CO2) challenge elicited similar BOLD, TOLD and pO2 responses. Strong correlations were observed between BOLD or response and quantitative 19F pO2 measurements. TOLD response showed a general trend with weaker correlation. Irradiation caused a significant tumor growth delay and tumors with larger changes in TOLD and R1 values upon oxygen breathing exhibited significantly increased tumor growth delay. Conclusion These results provide further insight into the relationships between oxygen sensitive (BOLD/TOLD) MRI and tumor pO2. Moreover, a larger increase in R1 response to hyperoxic gas challenge coincided with greater tumor growth delay following irradiation. Magn Reson Med 71:1863–1873, 2014.

26 December 2002 in Physical Review E
Verified
Journal Article
Closed access
PDF file
SSStrahinja Stojadinovic
Strahinja Stojadinovic
AAA. Adorjan
A. Adorjan
SSS. Sprunt
S. Sprunt
HSH. Sawade
H. Sawade
AJA. Jakli
A. Jakli
The dielectric fluctuations in the uniaxial nematic phase of a bent-core liquid crystal have been studied by dynamic light scattering. Polarization selection of the scattering cross-section reveals one mode due to ordinary director fluctuations and, in the lower part of the nematic phase, a second mode attributable to fluctuations of the biaxial order parameter. The director fluctuations are ∼100 times slower than observed in typical nematics based on straight-core molecules, suggesting that the bent core nematogenic units may be microscopic smectic domains (“cybotactic” clusters).

15 November 2007 in Medical Physics
Verified
Journal Article
Closed access
PDF file
SSStrahinja Stojadinovic
Strahinja Stojadinovic
DLD. A. Low
D. A. Low
AHA. J. Hope
A. J. Hope
MVM. Vicic
M. Vicic
JDJ. O. Deasy
J. O. Deasy
PGP. W. Grigsby
P. W. Grigsby

24 March 2006 in Physical Review E
Verified
Journal Article
Closed access
PDF file
DWD. Wiant
D. Wiant
SSStrahinja Stojadinovic
Strahinja Stojadinovic
KNK. Neupane
K. Neupane
SSS. Sharma
S. Sharma
KFK. Fodor-Csorba
K. Fodor-Csorba
SSS. Sprunt
S. Sprunt
Magnetic birefringence and dynamic light scattering measurements of orientational order parameter fluctuations at the isotropic-nematic phase transition of a bent-core liquid crystal reveal a pretransitional temperature dependence consistent with the standard Landau–deGennes mean field theory. However, as follows: the transition in the bent-core compound is more weakly first order (TNI−T*≈0.4°C), the leading Landau coefficient is ∼30 times lower, the viscosity associated with nematic order fluctuations is ∼10 times higher, and the density change is ∼10 times lower, than typically observed in calamitic (rod-shaped) liquid crystals. One consistent explanation for these anomalies is an optically isotropic phase composed of microscopic complexes or “clusters” of bent-core molecules.