Jungsoo Kim

Dr. Jungsoo Kim

The University of Sydney
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2013 in Journal of Environmental Psychology
Verified
Journal Article
Closed access
Jungsoo KimJungsoo Kim
Jungsoo Kim
RDRichard de Dear
Richard de Dear

1 September 2018 in Building and Environment
Verified
Journal Article
Open access
VLVeronika Földváry Ličina
Veronika Földváry Ličina
TCToby Cheung
Toby Cheung
HZHui Zhang
Hui Zhang
RDRichard de Dear
Richard de Dear
Thomas ParkinsonThomas Parkinson
Thomas Parkinson
XZXiang Zhou
Xiang Zhou

1 March 2012 in Building and Environment
Verified
Journal Article
Open access
Jungsoo KimJungsoo Kim
Jungsoo Kim
RDRichard de Dear
Richard de Dear

1 December 2013 in Building and Environment
Verified
Journal Article
Open access
Jungsoo KimJungsoo Kim
Jungsoo Kim
RDRichard de Dear
Richard de Dear
Christhina CandidoChristhina Candido
Christhina Candido
HZHui Zhang
Hui Zhang
EAEdward Arens
Edward Arens

8 January 2015 in Building Research & Information
Verified
Journal Article
Closed access
RDRichard de Dear
Richard de Dear
Jungsoo KimJungsoo Kim
Jungsoo Kim
Christhina CandidoChristhina Candido
Christhina Candido
MDMax Deuble
Max Deuble
This survey of thermal comfort in classrooms aimed to define empirically the preferred temperatures, neutral temperatures and acceptable temperature ranges for Australian school children, and to compare them with findings from adult populations. The survey was conducted in a mixture of air-conditioned, evaporative-cooled and naturally ventilated classrooms in nine schools located in three distinct subtropical climate zones during the summer of 2013. A total of 2850 questionnaires were collected from both primary (grade) and secondary (high) schools. An indoor operative temperature of about 22.5°C was found to be the students’ neutral and preferred temperature, which is generally cooler than expected for adults under the same thermal environmental conditions. Despite the lower-than-expected neutrality, the school children demonstrated considerable adaptability to indoor temperature variations, with one thermal sensation unit equating to approximately 4°C operative temperature. Working on the industry-accepted assumption that an acceptable range of indoor operative temperatures corresponds to group mean thermal sensations of −0.85 through to +0.85, the present analysis indicates an acceptable summertime range for Australian students from 19.5 to 26.6°C. The analyses also revealed between-school differences in thermal sensitivity, with students in locations exposed to wider weather variations showing greater thermal adaptability than those in more equable weather districts.