Tamara Wygnanski-Jaffe

Dr. Tamara Wygnanski-Jaffe

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in American Journal of Ophthalmology
Verified
Journal Article
Open access
OYOren Yehezkel
Oren Yehezkel
MBMichael Belkin
Michael Belkin
TWTamara Wygnanski-Jaffe
Tamara Wygnanski-Jaffe
Manual measurements of strabismus are subjective, time consuming, difficult to perform in babies, toddlers, and young children, and rely on the examiner's skill and experience. An automated system, based on eye tracking and dedicated full occlusion glasses, was developed to provide a fast, objective, and easy-to-use alternative to the manual measurements of strabismus. The objective of this study was to test the efficacy of the system in determining the presence of strabismus in children, as well as its type and the amount of deviation, in addition to differentiating between phorias and tropias. Prospective, masked, inter-rater reliability study. A prospective, masked, cross-sectional study included 69 children, aged 3-15 years. A cover uncover test (CUT) and a prism alternating cover test (PACT) for the primary gaze, at a distance of 50 cm, were performed by two independent, masked examiners and by the automated system. A high correlation was found between the automated and the manual tests, R=0.9, P<0.001 for the horizontal deviation, and R=0.91, P<0.001 for the vertical deviation, with 100% correct identification of the type of deviation. The average automated test duration was 46 seconds. The Bland-Altman plot, which compared the two measurement methods, showed a mean value of -2.9 PD and a half-width of the 95% limit of agreement of ±11.4 PD. The tested automated system provides precise detection and measurements of ocular misalignment and differentiates between phorias and tropias. It can be utilized in participants from 3 years of age and up.

1 September 2006 in Cornea
Verified
Journal Article
Closed access
TWTamara Wygnanski-Jaffe
Tamara Wygnanski-Jaffe
IBIrina S Barequet
Irina S Barequet
Purpose: The aim of this study was to compare central corneal thickness between eyes with congenital glaucoma and normal fellow eyes in unilateral glaucoma or less affected fellow eyes in bilateral glaucoma. Methods: Eyes of consecutive phakic children with congenital glaucoma and previous glaucoma surgery were examined under chloral hydrate. Complete ophthalmologic examination, central corneal thickness (CCT), axial length, and corneal diameter measurements were performed. Patients were included in the study if presented with intraocular pressure (IOP) less than 21 mm Hg and no biomicroscopic signs of corneal edema. Results: Nine patients were included in the study. The mean CCT in the more affected eye/glaucomatous eye was 522.3 ± 65.2 μm and in the less affected eye/healthy eye was 579.7 ± 44.5 μm. This difference was statistically significant (P = 0.0013). Conclusion: CCT was significantly thinner in glaucomatous eyes than in normal fellow eyes in phakic children with congenital glaucoma. This finding may be another confounding factor when measuring IOP in these patients.

2 July 2013 in Cutaneous and Ocular Toxicology
Verified
Journal Article
Closed access
PDF file
TWTamara Wygnanski-Jaffe
Tamara Wygnanski-Jaffe
Paolo NucciPaolo Nucci
Paolo Nucci
MGMauro Goldchmit
Mauro Goldchmit
EMEedy Mezer
Eedy Mezer
Objective: To assess the incidence of seizures induced by cycloplegic ophthalmic drops. Materials and methods: A survey among members of the American Association for Pediatric Ophthalmology and Strabismus yielded five patients who received cycloplegic eye drops between 1998 and 2010 and who consequently developed a seizure. Results: The median age of the patients was 5 years (range 3 months to 12 years). Cyclopentolate hydrochloride 1% was the only causative agent. The seizure happened on average 12 min after the instillation of dilating eye drops. Three were generalized convulsions, and two patients had a focal seizure. Past medical history was unremarkable in four cases. In total, 16 previous cases of seizures induced by cycloplegic drugs were identified in reports published between 1890 and 2004, implicating atropine in nine reports, tropicamide and phenylephrine eye drops in one and cyclopentolate in six. Discussion: A small amount of cyclopentolate drops could induce convulsions in young children after only minutes to less than an hour, while a larger dosage of atropine over the span of several hours could cause this rare and unpredictable complication. Predisposing factors were rare and those developing the seizures were healthy subjects. Generalized seizures were much more frequent than focal convulsions. Conclusions: Seizures after instillation of cycloplegic drops are extremely rare.

23 August 2024 in American Journal of Ophthalmology
Verified
Journal Article
Open access
TWTamara Wygnanski-Jaffe
Tamara Wygnanski-Jaffe
BKBurton J. Kushner
Burton J. Kushner
AMAvital Moshkovitz
Avital Moshkovitz
MBMichael Belkin
Michael Belkin
OYOren Yehezkel
Oren Yehezkel
To compare the effectiveness and safety of a novel binocular eye-tracking-based-home-treatment (CureSight) to patching for the treatment of amblyopia. Prospective, masked, multicenter randomized controlled trial. One hundred forty-nine children 4 to < 9 years with anisometropic, small-angle strabismic, or mixed-mechanism amblyopia were randomized to either binocular dichoptic treatment (n=75) or patching (n=74). The binocular dichoptic treatment group used the CureSight system for 90 min/day, 5 days/week for 16 weeks (120 hours). The patching group received 2-hour patching 7 days/week (224 hours). The primary outcome was the mean improvement from baseline in amblyopic eye visual acuity (VA) to week 16 in both study groups (non-inferiority of ≤0.10 logarithm of the minimum angle of resolution [logMAR]). In the modified intent-to-treat (mITT) group, the mean improvement from baseline at week 16 in the binocular treatment group was noninferior to patching group improvement (0.034 logMAR [95% CI -0.009 to 0.076]). In the per-protocol (PP) dataset, the mean improvement from baseline at week 16 in the binocular treatment group was superior to patching group improvement (0.05 logMAR ([95% CI; 0.007 to 0.097]). There was no significant between-group difference in the magnitude of improvement in stereoacuity in the mITT and the PP datasets. Median adherence in the mITT binocular treatment group (94.0%) was also significantly higher than in the patching group (83.9%; p=0.0038). A binocular, eye-tracking-based amblyopia home treatment is noninferior to, and produced better visual outcomes than, patching in children with anisometropic, small angle strabismus and mixed mechanism amblyopia.

18 July 2014 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
TWTamara Wygnanski-Jaffe
Tamara Wygnanski-Jaffe
ASAbraham Spierer
Abraham Spierer
SMShlomo Melamed
Shlomo Melamed
IBItay Ben-Zion
Itay Ben-Zion
Purpose: To report the effect of oral propranolol on intraocular pressure (IOP) in infants newly diagnosed with unilateral Sturge-Weber syndrome (SWS) glaucoma receiving no other treatment. Methods: This was a prospective, nonrandomized interventional case series. Four infants presenting with unilateral SWS glaucoma with no prior treatment were treated with oral propranolol at a dose of 2 mg/kg and followed thereafter. Results: Propranolol had a temporary IOP-lowering effect in 3 of 4 children after 1 week of treatment. This effect diminished thereafter and 3 of 4 children required additional medical or surgical treatment. Conclusions: Oral propranolol has a temporary effect on IOP in SWS glaucoma and is not effective as a single treatment in this syndrome, yet can serve to delay surgical treatment for a short period of time. In one case, the glaucoma was well-controlled on this medication.

1 September 2009 in Current Opinion in Ophthalmology
Verified
Journal Article
Closed access
EMEedy Mezer
Eedy Mezer
TWTamara Wygnanski-Jaffe
Tamara Wygnanski-Jaffe
To review some of the major issues in ophthalmic genetics ethics: predictive testing, prenatal testing and abortion, gene therapy, confidentiality, payment for genetic testing, the duty to recontact patients and convey new information. Patients and families may perceive benefits even though genetic testing may be associated with adverse psychosocial outcomes. Most patients were in favor of prenatal diagnosis but opposed abortion. Patient selection as candidates for gene therapy should be based on the different clinical characteristics of each hereditary disease. The balance between the right of the patient for confidentiality and the best interest of family members or society is an ethical challenge. Most insurance companies will pay for genetic testing if the condition is hereditary. The duty to recontact patients when new medical information becomes available is still ethically controversial. The field of ocular genetics is ever growing involving complex medical, technical, financial and social issues. As a result, ethical issues are expected to become more common. Properly prepared medical professionals as well as unique counseling for participants and families may enable improved decision-making taking into consideration the needs of each individual.