Enzo Allevard

Mr. Enzo Allevard

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RGRaúl Martín Gómez
Raúl Martín Gómez
EAEnzo Allevard
Enzo Allevard
HKHaye Kamstra
Haye Kamstra
JCJames Cotter
James Cotter
Peter LambPeter Lamb
Peter Lamb
Low-cost, portable devices capable of accurate physiological measurements are attractive tools for coaches, athletes, and practitioners. The purpose of this study was primarily to establish the validity and reliability of Movesense HR+ ECG measurements compared to the criterion three-lead ECG, and secondarily, to test the industry leader Garmin HRM. Twenty-one healthy adults participated in running and cycling incremental test protocols to exhaustion, both with rest before and after. Movesense HR+ demonstrated consistent and accurate R-peak detection, with an overall sensitivity of 99.7% and precision of 99.6% compared to the criterion; Garmin HRM sensitivity and precision were 84.7% and 87.7%, respectively. Bland–Altman analysis compared to the criterion indicated mean differences (SD) in RR’ intervals of 0.23 (22.3) ms for Movesense HR+ at rest and 0.38 (18.7) ms during the incremental test. The mean difference for Garmin HRM-Pro at rest was −8.5 (111.5) ms and 27.7 (128.7) ms for the incremental test. The incremental test correlation was very strong (r = 0.98) between Movesense HR+ and criterion, and moderate (r = 0.66) for Garmin HRM-Pro. This study developed a robust peak detection algorithm and data collection protocol for Movesense HR+ and established its validity and reliability for ECG measurement.

28 August 2026 in Journal of Biomechanics
Verified
Journal Article
Open access
EAEnzo Allevard
Enzo Allevard
TBThor F. Besier
Thor F. Besier
JCJulie Choisne
Julie Choisne

1 January 2026 in Journal of Applied Biomechanics
Verified
Journal Article
Closed access
EAEnzo Allevard
Enzo Allevard
CWConrad Werkhoven
Conrad Werkhoven
TBThor Besier
Thor Besier
Kelly SheerinKelly Sheerin
Kelly Sheerin
HWHannah Wyatt
Hannah Wyatt
JCJulie Choisne
Julie Choisne
Accurate reconstruction of full-body morphology is critical in many fields. This study evaluated the accuracy of 3 low-cost scanning technologies for capturing 3D body surface geometry: LiDAR sensors, ZOZOSUIT2, and ZOZO_v3. Participants were scanned using laser scan, LiDAR, and ZOZO’s methods. The scans were fitted to STAR models for comparison. The low-cost technologies captured 3D body surface geometry in an adult population, with RMSE values of 11.33 (4.39) mm (LiDAR), 7.13 (1.65) mm (ZOZOSUIT2), and 6.61 (1.93) mm (ZOZO_v3). All 3 methods demonstrated no gender bias in reconstruction accuracy.

17 July 2025 in Journal of Biomechanics
Verified
Journal Article
Closed access
RGRaúl Martín Gómez
Raúl Martín Gómez
HKHaye Kamstra
Haye Kamstra
EAEnzo Allevard
Enzo Allevard
LPLucas Pollet-Villard
Lucas Pollet-Villard
JCJames Cotter
James Cotter
Peter LambPeter Lamb
Peter Lamb