Bifacial c-Si photovoltaic (PV) modules can increase the performance of traditional PV modules because both sides of the cells, front and rear, absorb solar radiation. The knowledge of the temperature coefficients (TCs) is relevant to compare indoor and on-field performance of PV devices. In this paper, the TCs of c-Si bifacial PV modules from five different manufacturers were measured under natural sunlight and simulated indoor condition with a large-area steady-state solar simulator and the data were compared with the datasheet values. The effects on the TCs of an opaque and a reflective rear cover were also analyzed. There were no relevant differences between indoor and outdoor and for front and rear side TCs (within the measurement uncertainty). Slight differences with respect to the datasheet values were found for most of the modules under test for the TC for current α and for maximum power δ coefficients. However, since the manufacturers do not declare the TC uncertainty, a definitive statement cannot be made.
Bifacial crystalline Silicon (Si) photovoltaic (PV) devices are attracting considerable interest from manufacturers and the market since they can enhance the performance in comparison with traditional monofacial PV devices. Technical specification IEC TS 60904-1-2 was published in 2019 and proposes several characterization methods for bifacial PV device testing based on single-side, double-sided and natural sunlight illumination. This article analyses the advantages, disadvantages, the suitability and the feasibility of the different methods and compares the electrical performance obtained by the proposed approaches at the European Solar Test Installation for the testing of bifacial Si devices. Deviations in P max below 0.9% for the different testing methods under test was obtained except for the double-source approach with a rear reflector (2.59%) where the measurement of the rear irradaince influence the P max .
Performance measurements of photovoltaic devices, including metastable ones, should reflect as closely as possible the behaviour of these devices when deployed in the field, i.e. at constant illumination and fixed conditions. We review the wide-ranging behaviour observed in and previously proposed measurement solutions for perovskite solar cells (PSC) devices and further illustrate the variability during measurement with recent examples from our own experience. We propose a generic measurement protocol for PSC devices to ensure that electrical characterisation under simulated sunlight reflects real life conditions. The approach focusses on determining the steady-state maximum-power output under continuous illumination rather than relying on the I–V characteristics. Given the large variations in device behaviour, this protocol is particularly suitable in cases where a priori information about the devices under test is not available. We conclude that the approach to the electrical characterisation of PSC devices should shift from traditional I–V curves to the maximum-power output under steady-state conditions. The latter is the simplest and most reliable method to evaluate, assess and compare PSC technologies when power and efficiency reporting are required. This protocol also contributes to harmonising comparison between different calibration laboratories thus contributing to increased confidence in the results.
21 May 2019 in Progress in Photovoltaics: Research and Applications
This work presents the results of a high‐efficiency (HE) photovoltaic (PV) module round‐robin intercomparison between five Asian and European ISO/IEC 17025 accredited laboratories and one industrial laboratory based in Europe. The scope of the round‐robin was to examine the measurements comparability for this PV technology with respect to ISO/IEC 17025 laboratory conformity assessment and also to examine the accuracy of step‐like methods towards transient errors against already validated methods. The devices under test were four types of HE c‐Si PV modules with efficiencies varying between 16.5% and 19.0%. The results indicate that a satisfactory agreement was achieved with maximum deviations of 1.59% in Pmax, 1.13% in Isc, and 0.64% in Voc for all devices under test. The weighted standard deviations in Pmax per device type, which can be seen as a conservative estimate of interlaboratory agreement for HE c‐Si PV, ranged within 0.82% to 2.23% (k = 2). The accuracy of step‐like methods towards transient errors was evaluated by comparing a second series of results at fixed Isc for each module under test, eliminating the influence of the effective irradiance measurement. This work suggests that the contribution of capacitive errors was in the range (0.47 ± 0.19) % (k = 2). A spectral mismatch sensitivity analysis showed that an accurate measurement of the spectral irradiance and of the involved spectral responsivities together with the punctual correction for the spectral mismatch can reduce the error in the measurement of PV modules performance of about 2% even in the case of c‐Si against c‐Si and class AAA solar simulators.
8 October 2020 in Progress in Photovoltaics: Research and Applications
Today's variety of photovoltaic (PV) technologies imposes new challenges to laboratories and industries to precisely measure the performance of devices and, consequently, to accurately estimate the energy yield once installed in a specific location. Spectroradiometry has become a key discipline for metrology applied to PV: Spectral irradiance is one of the three parameters according to which solar simulators are classified according to IEC 60904‐9; precise spectrum measurements are a key factor in the spectral mismatch calculation. Finally, energy rating calculations according to IEC 61853 involve spectral irradiance conditions different than the AM1.5G standard spectrum. To tackle these issues, since 2011, the International Spectroradiometer Interlaboratory Comparison (ISRC) takes place annually in different locations of Europe with the participation of laboratories, research institutes, and industry partners to assess spectral measurement capabilities and share good measurement practices and protocols. In this paper, several results of the 9th ISRC 2019 are presented, looking in particular at the impact on characterization of new technologies like organic devices (OPV), dye‐sensitized (DSSC), and perovskites.
The international standard IEC62670-3 (International Electrotechnical Committee) “Photovoltaic Concentrators (CPV) Performance Testing—Part 3—Performance Measurements and Power Rating” sets the guidelines for power measurements of a CPV device, both in indoor and outdoor conditions. When measuring in outdoor conditions, the acquired data have to be filtered a posteriori, in order to select only those points measured with ambient conditions close to the Concentrator Standard Operating Conditions (CSOC). The most stringent requirement to be met is related to the three Spectral Matching Ratios (SMR), which have all to be within the limit of 1.00 ± 0.03. SMR are usually determined by the ratio of the currents of component cells to monitor the outdoor spectral ratio conditions during the CPV device power measurements. Experience demonstrates that obtaining real world data meeting these strict conditions is very difficult in practice. However, increasing the acceptable range would make the entire filtering process less appropriate from a physical point of view. Given the importance of correctly measuring the SMR, an estimation of their associated measurement uncertainties is needed to allow a proper assessment of the validity of the 3% limit. In this study a Monte Carlo simulation has been used, to allow the estimation of the propagation of uncertainties in expressions having the and integral form. The method consists of applying both random and wavelength correlated errors to the measured spectra and to the measured spectral responses of the three CPV cell junctions, according to the measurement uncertainties of the European Solar Test Installation (ESTI). The experimental data used in this study have been acquired during clear sky conditions in May 2016, at ESTI’s facilities in Ispra, northern Italy (45°49′ N 8°37′ E).