Wael El-Dakhakhni

Dr. Wael El-Dakhakhni

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2003 in Journal of Structural Engineering
Verified
Journal Article
Closed access
WEWael El-Dakhakhni
Wael El-Dakhakhni
MEMohamed Elgaaly
Mohamed Elgaaly
AHAhmad A. Hamid
Ahmad A. Hamid
Masonry infill panels in framed structures have been long known to affect strength, stiffness, and ductility of the composite structure. In seismic areas, ignoring the composite action is not always on the safe side, since the interaction between the panel and the frame under lateral loads dramatically changes the stiffness and the dynamic characteristics of the composite structure, and hence, its response to seismic loads. This study presents a simple method of estimating the stiffness and the lateral load capacity of concrete masonry-infilled steel frames (CMISFs) failing in corner crushing mode, as well as the internal forces in the steel frame members. In this method, each masonry panel is replaced by three struts with force-deformation characteristics based on the orthotropic behavior of the masonry infill. A simplified steel frame model is also presented based on the documented modes of failure of the CMISF. The method can be easily computerized and included in nonlinear analysis and design of three...

1 April 2011 in Composite Structures
Verified
Journal Article
Closed access
KKKian Karimi
Kian Karimi
MTMichael J. Tait
Michael J. Tait
WEWael El-Dakhakhni
Wael El-Dakhakhni

12 June 2008 in Measurement Science and Technology
Verified
Journal Article
Closed access
ANAmr A Nassr
Amr A Nassr
WAWael H Ahmed
Wael H Ahmed
WEWael El-Dakhakhni
Wael El-Dakhakhni

1 November 2008 in Journal of Structural Engineering
Verified
Journal Article
Closed access
MSMarwan T. Shedid
Marwan T. Shedid
RDRobert G. Drysdale
Robert G. Drysdale
WEWael El-Dakhakhni
Wael El-Dakhakhni
In this paper, the possibility of achieving a high level of ductility by flexural yielding in fully grouted reinforced concrete masonry shear walls is evaluated. Six full-scale walls were tested to failure under reversed cyclic lateral loading to investigate the effects of amount and distribution of vertical reinforcement and the level of axial compressive stress on the inelastic behavior and ductility. Results showed that yielding of the outermost vertical bars extended to a height equivalent to half the wall length. Also, the top wall displacement (drift) at the onset of yielding of the vertical reinforcement was highly dependent on the amount of reinforcement, but only minimally affected by the level of axial compressive load. However, at maximum loads, the displacements were less sensitive to either the amount of vertical reinforcement or the level of axial compression. Correspondingly, the displacement ductility was found to be very sensitive to the amount of vertical reinforcement, but was not depen...

1 December 2006 in Engineering Structures
Verified
Journal Article
Closed access
SISherif A. Ibrahim
Sherif A. Ibrahim
WEWael El-Dakhakhni
Wael El-Dakhakhni
MEMohamed Elgaaly
Mohamed Elgaaly

1 June 2010 in Journal of Structural Engineering
Verified
Journal Article
Closed access
MSMarwan T. Shedid
Marwan T. Shedid
WEWael El-Dakhakhni
Wael El-Dakhakhni
RDRobert G. Drysdale
Robert G. Drysdale
In this paper, seven reinforced concrete-block shear walls with aspect ratios of 1.5 and 2.2 (two- and three-storey high) were tested under displacement-controlled cyclic loading. The response of rectangular, flanged, and end-confined walls, designed to have the same lateral resistance when subjected to the same axial load, is discussed. In general, high levels of ductility accompanied by relatively small strength degradation were observed in all walls with a significant increase in ductility and displacement capabilities for the flanged and end-confined walls compared to the rectangular ones. For both aspect ratios evaluated, the drift levels at 20% strength degradation were 1.0, 1.5, and 2.2% corresponding to the rectangular, the flanged, and the end-confined walls, respectively. The ductility values of the proposed flanged and end-confined walls were, respectively, 1.5 and 2 times those of their rectangular wall counterparts (with the same overall length and aspect ratio). In addition to the enhanced ductility, a saving of more than 40% in the amount of vertical reinforcement was achieved using the proposed alternative strategies while maintaining the same lateral wall resistance. Existing design clauses were used to predict the wall capacities using the American and the Canadian masonry codes and showed excellent agreement. This will facilitate adoption of the new construction categories with minimal modifications to existing code clauses. The test results indicate that higher ductility than the currently endorsed values by North American codes should be used for rectangular walls. Moreover, higher values should be expected when the proposed strategies are adopted which would significantly reduce the seismic demand on reinforced concrete-block shear wall construction.