Oleg Kul

Dr. Oleg Kul


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AVAlexey Vasiliev
Alexey Vasiliev
Alexey ShaposhnikAlexey Shaposhnik
Alexey Shaposhnik
PMPavel V. Moskalev
Pavel V. Moskalev
OKOleg Kul
Oleg Kul
In this work, the kinetics and mechanisms of the interaction of carbon monoxide and hydrogen with the surface of a nanosized SnO2–PdOx metal oxide material in air is studied. Non-stationary temperature regimes make it possible to better identify the individual characteristics of target gases and increase the selectivity of the analysis. Recently, chemometric methods (PCA, PLS, ANN, etc.) are often used to interpret multidimensional data obtained in non-stationary temperature regimes, but the analytical solution of kinetic equations can be no less effective. In this regard, we studied the kinetics of the interaction of carbon monoxide and hydrogen with atmospheric oxygen on the surface of SnO2–PdOx using semiconductor metal oxide sensors under conditions as close as possible to classical gas analysis. An analysis of the influence of catalytic surface temperature on the mechanisms of chemisorption processes allowed us to correctly interpret and mathematically describe the electrophysical characteristics of the sensor in the selective determination of carbon monoxide and hydrogen under nonstationary temperature conditions. The reaction mechanism is applied as well to the analysis of the operation scheme of the CO sensor TGS 2442 of Figaro Inc.

30 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
AVAlexey Vasiliev
Alexey Vasiliev
Alexey ShaposhnikAlexey Shaposhnik
Alexey Shaposhnik
OKOleg Kul
Oleg Kul
Artem S. MokrushinArtem S. Mokrushin
Artem S. Mokrushin
The analysis of the influence of microhotplate size on the convective heat exchange of gas sensors is presented. Usually, the role of convection in the heat exchange of gas sensors is not considered in thermal simulation models because of the complexity of the convection process. As a result, the contribution of this process to the overall heat loss of sensors remains without detailed analysis. We analyzed convection issues in two groups of gas sensors: semiconductor and thermocatalytic (calorimetric) sensors and, on the other hand, in the oxygen sensors of the thermomagnetic type. It is demonstrated that there is a critical size leading to the formation of convective heat exchange flow. Below this critical value, only thermal conductivity of ambient air, IR (infrared) radiation from the heated microhotplate surface, and thermal conductivity of the microhotplate-supporting elements should be considered as channels for heat dissipation by the microhotplate, and the contribution of free convection can be neglected. The expression for the critical size contains only fundamental constants of air, dcr~4·ν·Dg3, where ν is the kinematic viscosity of air, D is the diffusion coefficient, and g is the acceleration of free fall, dcr~0.5 cm. Therefore, if the size of the microhotplate d <<dcr, the influence of convection heat exchange can be neglected. Similar results were obtained in the analysis of the behavior of thermal magnetic sensors of oxygen, which use paramagnetic properties of molecular oxygen for the determination of O2 concentration. In this case, the critical size of the sensor is also of significance; if the size of the magnetic sensor is much below this value, the oxygen concentration value measured with such a device is independent of the orientation of the sensor element. The results of the simulation were compared with the measurement of heat loss in micromachined gas sensors. The optimal dimensions of the sensor microhotplate are given as a result of these simulations and measurements.

3 April 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
AVAlexey Vasiliev
Alexey Vasiliev
Alexey ShaposhnikAlexey Shaposhnik
Alexey Shaposhnik
OKOleg Kul
Oleg Kul
The analysis of the influence of microhotplate size on the convective heat exchange of gas sen-sors is presented. It is demonstrated that there is a minimum size leading to the formation of convection heat exchange flow. Below this minimum, only the thermal conductivity of ambient air and IR radiation should be considered as channels for heat dissipation by microhotplate. This limit expression contains only fundamental constants of air, d~4·ν·Dg3, where ν is the kinematic viscosity of air, D is the diffusion coefficient, and g is the acceleration of free fall, d~0.5 cm.

1 April 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
OKOleg Kul
Oleg Kul
AVAlexey Vasiliev
Alexey Vasiliev
ANAndrey Nikitin
Andrey Nikitin
ADAnna Dmitrieva
Anna Dmitrieva
ABAlexandr Bolshakov
Alexandr Bolshakov
We developed a new approach to the fabrication of MEMS (Microelectromechanical system) substrates for gas sensors. This full screen-printing approach consists in the application of sacrificial material, which is solid at the near-room temperature of printing and becomes powder after firing of the elements of the sensor and, therefore, can be removed from under the suspended elements of the MEMS structure in an ultrasonic bath. The glass–ceramic MEMS is a cantilever structure equipped with a Pt-based microheater on the end edge with the sensing layer. Screen-printing provides cheap fabrication, robustness, and low power (~120 mW at 450 °C) for the sensing element.