Amandine Dubois

Dr. Amandine Dubois

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ADAmandine Dubois
Amandine Dubois
TBTitus Bihl
Titus Bihl
JBJean-Pierre Bresciani
Jean-Pierre Bresciani
Because of population ageing, fall prevention represents a human, economic, and social issue. Currently, fall-risk is assessed infrequently, and usually only after the first fall occurrence. Home monitoring could improve fall prevention. Our aim was to monitor daily activities at home in order to identify the behavioral parameters that best discriminate high fall risk from low fall risk individuals. Microsoft Kinect sensors were placed in the room of 30 patients temporarily residing in a rehabilitation center. The sensors captured the patients’ movements while they were going about their daily activities. Different behavioral parameters, such as speed to sit down, gait speed or total sitting time were extracted and analyzed combining statistical and machine learning algorithms. Our algorithms classified the patients according to their estimated fall risk. The automatic fall risk assessment performed by the algorithms was then benchmarked against fall risk assessments performed by clinicians using the Tinetti test and the Timed Up and Go test. Step length, sit-stand transition and total sitting time were the most discriminant parameters to classify patients according to their fall risk. Coupling step length to the speed required to stand up or the total sitting time gave rise to an error-less classification of the patients, i.e., to the same classification as that of the clinicians. A monitoring system extracting step length and sit-stand transitions at home could complement the clinicians’ assessment toolkit and improve fall prevention.

22 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
ADAmandine Dubois
Amandine Dubois
TBTitus Bihl
Titus Bihl
JBJean-Pierre Bresciani
Jean-Pierre Bresciani
Fall prevention is a human, economic and social issue. The Timed Up and Go (TUG) test is widely used to identify individuals with a high fall risk. However, this test has been criticized because its “diagnostic” is too dependent on the conditions in which it is performed and on the healthcare professionals running it. We used the Microsoft Kinect ambient sensor to automate this test in order to reduce the subjectivity of outcome measures and to provide additional information about patient performance. Each phase of the TUG test was automatically identified from the depth images of the Kinect. Our algorithms accurately measured and assessed the elements usually measured by healthcare professionals. Specifically, average TUG test durations provided by our system differed by only 0.001 s from those measured by clinicians. In addition, our system automatically extracted several additional parameters that allowed us to accurately discriminate low and high fall risk individuals. These additional parameters notably related to the gait and turn pattern, the sitting position and the duration of each phase. Coupling our algorithms to the Kinect ambient sensor can therefore reliably be used to automate the TUG test and perform a more objective, robust and detailed assessment of fall risk.

1 March 2018 in Journal of Biomechanics
Verified
Journal Article
Closed access
ADAmandine Dubois
Amandine Dubois
JBJean-Pierre Bresciani
Jean-Pierre Bresciani

19 June 2017 in Journal of Ambient Intelligence and Smart Environments
Verified
Journal Article
Closed access
PDF file
ADAmandine Dubois
Amandine Dubois
FCFrançois Charpillet
François Charpillet
This work concerns the development of low-cost ambient systems for helping elderly to stay at home. Depth cameras allow a real-time analysis of the displacement of the person. We show that it is possible to recognize the activity of the person and to

11 June 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ADAmandine Dubois
Amandine Dubois
AMAudrey Mouthon
Audrey Mouthon
RSRanjith Steve Sivagnanaselvam
Ranjith Steve Sivagnanaselvam
JBJean-Pierre Bresciani
Jean-Pierre Bresciani
Falls in the elderly constitute a major health issue associated to population ageing. Current clinical tests evaluating fall risk mostly consist in assessing balance abilities. The devices used for these tests can be expensive or inconvenient to set up. We investigated whether, how and to which extent fall risk could be assessed using a low cost ambient sensor to monitor balance tasks. Eighty four participants, forty of which were 65 or older, performed eight simple balance tasks in front of a Microsoft Kinect sensor. Custom-made algorithms coupled to the Kinect sensor were used to automatically extract body configuration parameters such as body centroid and dispersion. Participants were then classified in two groups using a clustering method. The clusters were formed based on the parameters measured by the sensor for each balance task. For each participant, fall risk was independently assessed using known risk factors as age and average physical activity, as well as the participant’s performance on the Timed Up and Go clinical test. Standing with a normal stance and the eyes closed on a foam pad, and standing with a narrow stance and the eyes closed on regular ground were the two balance tasks for which the classification’s outcome best matched fall risk as assessed by the three known risk factors. Standing on a foam pad with eyes closed was the task driving to the most robust results. Our method constitutes a simple, fast, and reliable way to assess fall risk more often with elderly people. Importantly, this method requires very little space, time and equipment, so that it could be easily and frequently used by a large number of health professionals, and in particular by family physicians. Therefore, we believe that the use of this method would substantially contribute to improve fall prevention. Trial registration: CER-VD 2015-00035. Registered 7 December 2015.

13 August 2018 in Informatics for Health and Social Care
Verified
Journal Article
Closed access
ADAmandine Dubois
Amandine Dubois
TBTitus Bihl
Titus Bihl
JBJean-Pierre Bresciani
Jean-Pierre Bresciani
Fall risk assessment is usually conducted in specialized centers using clinical tests. Most of the time, these tests are performed only after the occurrence of health problems potentially affecting gait and posture stability. Our aim is to define fall risk indicators that could routinely be used at home to automatically monitor the evolution of fall risk over time. We used the standard Timed Up and Go (T.U.G.) test to classify 43 individuals into two classes of fall risk, namely high- vs low- risk. Several parameters related to the gait pattern and the sitting position included in the T.U.G. test were automatically extracted using an ambient sensor (Microsoft Kinect sensor). We were able to correctly classify all individuals using machine learning on the combination of two parameters among gait speed, step length and speed to sit down. Coupled to an ambient sensor installed at home to monitor the relevant parameters in daily activities, these algorithms could therefore be used to assess the evolution of fall risk, thereby improving fall prevention.