Jurgen Schmoll

Dr. Jurgen Schmoll

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2011 in Experimental Astronomy
Verified
Journal Article
Open access
PDF file
TCThe CTA Consortium
The CTA Consortium
MAM. Actis
M. Actis
GAG. Agnetta
G. Agnetta
FAF. Aharonian
F. Aharonian
AAA. Akhperjanian
A. Akhperjanian
PZP. Zychowski
P. Zychowski
Ground-based gamma-ray astronomy has had a major breakthrough with the impressive results obtained using systems of imaging atmospheric Cherenkov telescopes. Ground-based gamma-ray astronomy has a huge potential in astrophysics, particle physics and cosmology. CTA is an international initiative to build the next generation instrument, with a factor of 5–10 improvement in sensitivity in the 100 GeV–10 TeV range and the extension to energies well below 100 GeV and above 100 TeV. CTA will consist of two arrays (one in the north, one in the south) for full sky coverage and will be operated as open observatory. The design of CTA is based on currently available technology. This document reports on the status and presents the major design concepts of CTA.

1 March 2013 in Astroparticle Physics
Verified
Journal Article
Closed access
BAB.S. Acharya
B.S. Acharya
MAM. Actis
M. Actis
TAT. Aghajani
T. Aghajani
GAG. Agnetta
G. Agnetta
JAJ. Aguilar
J. Aguilar
PŻP. Żychowski
P. Żychowski

1 June 2005 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Closed access
MRMartin M. Roth
Martin M. Roth
AKAndreas Kelz
Andreas Kelz
TFThomas Fechner
Thomas Fechner
THThomas Hahn
Thomas Hahn
SBSvend‐Marian Bauer
Svend‐Marian Bauer
WAWerner Altmann
Werner Altmann
We describe the design, manufacture, commissioning, and performance of PMAS, the Potsdam Multi-Aperture Spectrophotometer. PMAS is a dedicated integral field spectrophotometer, optimized to cover the optical wavelength regime of 0.35--1um. It is based on the lens array -- fiber bundle principle of operation. The instrument employs an all-refractive fiber spectrograph, built with CaF2 optics, to provide good transmission and high image quality over the entire nominal wavelength range. A set of user-selectable reflective gratings provides low to medium spectral resolution in first order of approx. 1.5, 3.2, and 7 A, depending on the groove density (1200, 600, 300 gr/mm). While the standard integral field unit (IFU) uses a 16x16 element lens array, which provides seeing-limited sampling in a relatively small field-of-view (FOV) in one of three magnifications (8x8, 12x12, or 16x16 arcsec^2, respectively), a recently retrofitted bare fiber bundle IFU (PPak) expands the FOV to a hexagonal area with a footprint of 65x74 arcsec^2. Other special features include a cryogenic CCD camera for field acquisition and guiding, a nod-shuffle mode for beam switching and improved sky background subtraction, and a scanning Fabry-Perot etalon in combination with the standard IFU (PYTHEAS mode). PMAS was initially designed and built as an experimental traveling instrument with optical interfaces to various telescopes (Calar Alto 3.5m, ESO-VLT, LBT). It is offered as a common user instrument at Calar Alto under contract with MPIA Heidelberg since 2002.

8 November 2024 in The Astronomical Journal
Verified
Journal Article
Open access
PDF file
CPClaire Poppett
Claire Poppett
LTLuke Tyas
Luke Tyas
JAJ. Aguilar
J. Aguilar
CBChristopher Bebek
Christopher Bebek
DBD. Bramall
D. Bramall
RZR. Zhou
R. Zhou
The Dark Energy Spectroscopic Instrument (DESI) is a revolutionary instrument designed for precise measurements of cosmic distances and the investigation of dark energy. DESI utilizes 5000 optical fibers to simultaneously measure the spectra of distant objects and aims to measure 40 million galaxies and quasars in a 5 yr survey. One of the critical challenges to DESI’s success was ensuring that the fiber system was not only highly efficient but also delivered a highly stable beam enabling more reliable sky subtraction for measurements of faint objects. We achieved this stability by minimizing the stress on the fiber system during the manufacture and operation of the telescope and fiber positioning robots. We installed the DESI fiber system on the 4 m Mayall telescope with ≥99% of fibers intact, and the instrument has delivered superb optical performance throughout the initial years of the DESI survey, including ≥90% average throughput when injected with a focal ratio of ∼f/3.9 as delivered by the primary focus corrector, excluding fiber absorption losses. The design of DESI required multiple innovations to achieve these requirements, such as cleaved fibers bonded with a UV-curing epoxy to glass ferrules in the focal plane and fusion splicing instead of physical connectors. In this paper, we describe the development, delivery, and installation of the fiber system, the innovations that made the state-of-the-art performance possible, and the key lessons learned that could benefit future projects.

7 August 2015 in Science Advances
Verified
Journal Article
Open access
PDF file
MBMartin S Banks
Martin S Banks
WSWilliam W. Sprague
William W. Sprague
JSJurgen Schmoll
Jurgen Schmoll
JPJared A. Q. Parnell
Jared A. Q. Parnell
GLGordon Love
Gordon Love
A novel explanation of why certain pupil shapes are visually advantageous for terrestrial animals in different ecological niches.

1 April 1998 in The Astrophysical Journal Supplement Series
Verified
Journal Article
Open access
PDF file
MDM. Dietrich
M. Dietrich
BPB. M. Peterson
B. M. Peterson
PAP. Albrecht
P. Albrecht
MAM. Altmann
M. Altmann
ABA. J. Barth
A. J. Barth
ZZZ. L. Zou
Z. L. Zou
Results of a ground-based optical monitoring campaign on 3C 390.3 in 1994-95 are presented. The broad-band fluxes (B, V, R, and I), the spectrophotometric optical continuum flux F(5177) and the integrated emission-line fluxes of Ha, Hb, Hg, HeI, and HeII all show a nearly monotonic increase with episodes of milder short-term variations superposed. The amplitude of the continuum variations increases with decreasing wavelength (4400-9000 A). The optical continuum variations follow the variations in the ultraviolet and X-ray with time delays, measured from the centroids of the cross- correlation functions, typically around 5 days, but with uncertainties also typically around 5 days; zero time delay between the high-energy and low-energy continuum variations cannot be ruled out. The strong optical emission lines Ha, Hb, Hg, and HeI respond to the high-energy continuum variations with time delays typically about 20 days, with uncertainties of about 8 days. There is some evidence that HeII responds somewhat more rapidly, with a time delay of around 10 days, but again, the uncertainties are quite large (~8 days). The mean and rms spectra of the Ha and Hb line profiles provide indications for the existence of at least three distinct components located at +-4000 and 0 km/s relative to the line peak. The emission-line profile variations are largest near line center.Comment: 42 pages (Latex), 13 figures, 14 table