Developed to achieve the balancing of three-phase loads and improve their power factor, the BCC (Balancing Capacitive Compensator) is presented in this paper as having a broader capability, namely that of balancing the two-way power flow. BCCs are becoming useful in today’s distribution networks with a high content of DERs (Distributed Energy Resources), where unbalanced power transfers to the higher voltage network occur more and more frequently as a result of the excess power generated. The article contains a case study in which, by means of Matlab-Simulink 2021 modelling, such a network is studied by considering two regimes corresponding to the two-way power flow. The numerical analysis of phase components and sequence components confirms the validity of the mathematical model concerning the BCC and also for the case of changing the way of power flow in the section controlled by the compensator. This demonstrates the possibility of extending the load balancing function of the BCC to that of balancing the two-way power flow and is an additional argument in support of replacing, in the more or less near future, conventional shunt capacitive compensators with capacitive balancing compensators.

18 July 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JAJorza Andrei
Jorza Andrei
APAdrian Pană
Adrian Pană
FMFlorin Molnar-Matei
Florin Molnar-Matei
ABAlexandru Baloi
Alexandru Baloi
IBIlona Bucatariu
Ilona Bucatariu
One of the negative effects of the rapid increase in the number and capacity of photovoltaic power sources distributed in consumption areas by connecting to existing low-, medium-, and high-voltage distribution networks is the increased risk of amplifying the non-sinusoidal steady-state condition caused by high-power inverters. This amplification occurs if the peak values of harmonic impedance in the sections of the respective grid zone, which depend on the values of the equivalent shunt capacitances present in the grid, correspond to frequency values that coincide with or are close to the frequencies of the harmonic currents injected by the distributed sources. The risk is particularly high in cases of malfunction or failure of the filters within the installations associated with these sources. High shunt capacitance values are not only caused by the capacitive compensators used to increase the power factor of consumers or to improve the voltage level in the grid, but also by long power lines, particularly long underground lines. Risks increase as the proportion of underground power lines in the network area with sources of harmonic currents rises. This article refers to a real high-voltage grid area where the distribution operator plans to install high-power photovoltaic sources, the connection of which requires grid expansion through the construction of new substations and high-voltage power lines (110 kV). Based on the designer’s intention for the new high-voltage power lines to be underground and of relatively long lengths—which implies the presence of high natural capacitances—the authors conduct two case studies to predictively evaluate the harmonic impedance in the network sections resulting from the expansion, with the aim of identifying the frequencies at which parallel resonances may occur. The authors use two software tools for numerical analysis, Mathcad 14.0 and MATLAB–Simulink 2025A, and compare the results obtained for two design variants of the new high-voltage lines: overhead and underground, respectively. Using the mathematical model of long lines in steady state with uniformly distributed parameters, the analysis highlights that the highest values of harmonic impedance correspond to the overhead line design variant. The use of this design variant increases the risk of parallel resonances, not only by increasing the harmonic impedance values but also by widening the frequency ranges for which the impedance has high values. In both the overhead line and underground line variants, increasing the load leads to a reduction in the maximum values. Compared to the design variant using overhead lines, the variant with underground lines increases the risk of parallel resonances by increasing the number of frequency intervals for which the harmonic impedance has high values, but this increase is limited by narrowing these frequency intervals and reducing the harmonic impedance values. An important contribution of the article lies in arguing the need to extend the conventional node-based evaluation of harmonic impedance by treating harmonic impedance as a continuous spatial frequency characteristic of the transmission network. The impedances seen at nodes become the impedances seen in particular sections/sections of the network, identified by the value of the variable that specifies their position in space, more precisely the distance from the end of one of the feeders on which they are located.