BACKGROUND: Atrial fibrillation (AF) events in cardiac implantable electronic devices (CIEDs) are temporally associated with stroke risk. This study explores temporal differences in AF burden associated with HF hospitalization risk in patients with CIEDs. METHODS: Patients with HF events from the Optum de-identified Electronic Health Records from 2007 to 2021 and 120 days of preceding CIED-derived rhythm data from a linked manufacturer’s data warehouse were included. AF burden ≥5.5 h/d was defined as an AF event. The AF event burden in the case period (days 1–30 immediately before the HF event) was considered temporally associated with the HF event and compared with the AF event burden in a temporally dissociated control period (days 91–120 before the HF event). The odds ratio for temporally associated HF events and the odds ratio associated with poorly rate-controlled AF (>110 bpm) were calculated. RESULTS: In total, 7257 HF events with prerequisite CIED data were included; 957 (13.2%) patients had AF events recorded only in either their case (763 [10.5%]) or control (194 [2.7%]) periods, but not both. The odds ratio for a temporally associated HF event was 3.93 (95% CI, 3.36–4.60). This was greater for an HF event with a longer stay of >3 days (odds ratio, 4.51 [95% CI, 3.57–5.68]). In patients with AF during both the control and case periods, poor AF rate control during the case period also increased HF event risk (1.78 [95% CI, 1.22–2.61]). In all, 222 of 4759 (5%) patients without AF events before their HF event had an AF event in the 10 days following. CONCLUSIONS: In a large real-world population of patients with CIED devices, AF burden was associated with HF hospitalization risk in the subsequent 30 days. The risk is increased with AF and an uncontrolled ventricular rate. Our findings support AF monitoring in CIED algorithms to prevent HF admissions.
Background: Ambulatory risk stratification for worsening heart failure (HF) using diagnostics measured by insertable cardiac monitors (ICM) may depend on the left ventricular ejection fraction (LVEF). We evaluated risk stratification performance in patients with reduced versus preserved LVEF. Methods: ICM patients with a history of HF events (HFEs) were included from the Optum® de-identified Electronic Health Record dataset merged with ICM device-collected data during 2007–2021. ICM measures nighttime heart rate (NHR), heart rate variability (HRV), atrial fibrillation (AF) burden, rate during AF, and activity duration (ACT) daily. Each diagnostic was categorized into high, medium, or low risk using previously defined features. HFEs were HF-related inpatient, observation unit, or emergency department stays with IV diuresis administration. Patients were divided into two cohorts: LVEF ≤ 40% and LVEF > 40%. A marginal Cox proportional hazards model compared HFEs for different risk groups. Results: A total of 1020 ICM patients with 18,383 follow-up months and 301 months with HFEs (1.6%) were included. Monthly evaluations with a high risk were 2.3, 4.2, 5.0, and 4.5 times (p < 0.001 for all) more likely to have HFEs in the next 30 days compared to those with a low risk for AF, ACT, NHR, and HRV, respectively. HFE rates were higher for patients with LVEF > 40% compared to LVEF ≤ 40% (2.0% vs. 1.3%), and the relative risk between high-risk and low-risk for each diagnostic parameter was higher for patients with LVEF ≤ 40%. Conclusions: Diagnostics measured by ICM identified patients at risk for impending HFEs. Patients with preserved LVEF showed a higher absolute risk, and the relative risk between risk groups was higher in patients with reduced LVEF.
Early detection of left ventricular systolic dysfunction (LVSD) using minimally invasive electrocardiographic assessment in an ambulatory setting may be important considering the increasing economic burden of heart failure. Recently artificial intelligence (AI) algorithms have been reported to classify reduced ejection fraction using a 12-lead ECG measurement snapshot. However, the studies of AI to identify LVSD using only a single lead ambulatory ECG (aECG) are limited. We developed a convolution neural network based deep learning algorithm (CNN-aECG) to predict left ventricular ejection fraction (LVEF) less than 40% using aECG from implantable loop recorders (ILR). A total of 35,741 unique LVEF-aECG pairs collected from 2,249 ILR patients were used to train the model. The model yielded accuracy, sensitivity, specificity, and AUC of 75%, 70%, 76% and 0.8 respectively in the independent test set of 6,611 unique LVEF-aECG pairs from 750 patients. This proposed method of ambulatory CNN-aECG monitoring may allow for identifying reduced ejection fraction post ILR implant via remote monitoring.
Background: Early detection of left ventricular systolic dysfunction (LVSD) using minimally invasive electrocardiographic assessment in an ambulatory setting may be important considering the increasing economic burden of HF. Recently artificial intelligence (AI) algorithms have been reported to classify reduced ejection fraction using snapshot 12-lead ECG measurements, however the ability of AI to identify LVSD using only a single lead ambulatory ECG is unknown. Purpose: We aimed to develop a convolution neural network (CNN) based deep learning algorithm using single lead ECG to predict ejection fraction less than 40% in ambulatory patients implanted with implantable loop recorders (ILRs). Methods: We linked ILR patients with LVEF measurements from a de-identified database of aggregated electronic health record (EHR) data during the period of 2007-2021 to a manufacturer’s device database with ambulatory single lead ECGS. The routine ECG transmissions from the ILR devices were paired with LVEF measured within a week. The data was pre-processed to obtain the time-frequency components of ECG using wavelet transform. The wavelet coefficients were then used as input to train and validate a 2D-CNN model. An independent test dataset consisting of data from patient not included in training/validation dataset was used to assess the performance of CNN model to classify LVEF< = 40% using the metrics area under the curve (AUC), sensitivity and specificity. Results: A total of 35,741 unique LVEF-ECG pairs collected from 2,249 ILR patients were used to train the model; an independent validation dataset consisted of 6,721 unique LVEF ECG pairs from 750 patients and independent test dataset consisted of 6,611 unique LVEF ECG pairs from 750 patients. In our CNN model, cross entropy was used as loss function and adaptive moment estimation (ADAM) was used as the optimizer. The initial learning rate was selected as 0.0001, epochs as 20 and mini batch size as 64. The threshold to delineate reduced ejection fraction (LVEF< = 40%) was set as 0.1 (Figure 1). The model yielded accuracy, sensitivity, specificity, AUC of 75%,70%, 76% and 0.8 respectively in the independent test set (Figure 2). Conclusion: A deep learning algorithm applied to ambulatory single lead ECGs acquired by ILR can detect LVEF< = 40%. This continuous ambulatory AI-ECG monitoring may allow to identify longitudinal changes in LVEF post ILR implant via remote monitoring.Figure 1:Model output vs Actual EF rangeFigure 2:ROC