Lucian Rotariu

Dr. Lucian Rotariu


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
LRLucian Rotariu
Lucian Rotariu
FLFlorence Lagarde
Florence Lagarde
NJNicole Jaffrezic-Renault
Nicole Jaffrezic-Renault
Camelia BalaCamelia Bala
Camelia Bala

1 November 2011 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LZLucian-Gabriel Zamfir
Lucian-Gabriel Zamfir
Elisabeta-Irina GeanaElisabeta-Irina Geana
Elisabeta-Irina Geana
SBSondes Bourigua
Sondes Bourigua
LRLucian Rotariu
Lucian Rotariu
Camelia BalaCamelia Bala
Camelia Bala
NJNicole Jaffrezic-Renault
Nicole Jaffrezic-Renault

1 July 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
SASawsen Azzouzi
Sawsen Azzouzi
LRLucian Rotariu
Lucian Rotariu
Ana M. BenitoAna M. Benito
Ana M. Benito
WMWolfgang K. Maser
Wolfgang K. Maser
BMBen Ali Mounir
Ben Ali Mounir
Camelia BalaCamelia Bala
Camelia Bala
In this work, a novel amperometric biosensor based on gold nanoparticles anchored on reduced graphene oxide (RGO-AuNPs) and l-lactate dehydrogenase (LDH) was developed for the sensing of l-lactate. Firstly, the RGO-AuNPs modified screen printed electrodes were tested for NADH detection showing a wide dynamic range and a low detection limit. Next, the biosensor was constructed by incorporating both enzyme and RGO-AuNPs in a sol gel matrix derived from tetrametoxysilane and methyltrimetoxysilane. The enzyme loading, working pH, and coenzyme concentration were optimized. The biosensor linearly responded to l-lactate in the range of 10µM-5mM and showed a good specific sensitivity of 154µA/mMcm(2) with a detection limit of 0.13µM. This was accompanied by good reproducibility and operational stability. Tests on artificial serum proved that l-lactate can be determined practically without interferences from commonly interfering compounds such as urate, paracetamol and l-ascorbate. Our LDH/RGO-AuNPs/SPCE based biosensor thus performs as electrochemical device for the detection of l-lactate as a viable early cancer bio-marker.


1 February 2012 in Analytical Biochemistry
Verified
Journal Article
Closed access
Mihaela PuiuMihaela Puiu
Mihaela Puiu
OIOana Istrate
Oana Istrate
LRLucian Rotariu
Lucian Rotariu
Camelia BalaCamelia Bala
Camelia Bala