Kinga Sekuła

Ms. Kinga Sekuła

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2026 in Materials
Verified
Journal Article
Open access
PDF file
PSPaulina Sobierajska
Paulina Sobierajska
Maciej DobrzyńskiMaciej Dobrzyński
Maciej Dobrzyński
Kinga Grzech-LeśniakKinga Grzech-Leśniak
Kinga Grzech-Leśniak
KSKinga Sekuła
Kinga Sekuła
DSDamian Szymański
Damian Szymański
Rafal Jakub WigluszRafal Jakub Wiglusz
Rafal Jakub Wiglusz
The dynamic development of laser therapy in dentistry is associated, among other factors, with the bactericidal effect of the energy emitted by laser devices. Therefore, they are also helpful for decontamination. They are increasingly used in the treatment of peri-implantitis, a bacterial inflammation of peri-implant tissues that is the most severe late complication of implantation and a potential cause of implant loss. Therefore, this study aimed to assess the safety of laser decontamination of the implant surface with respect to its effect on the integrity of the implant structure. In the present study, blocks of the titanium alloys Ti-6Al4V and Ti6Al7Nb were fabricated using electron-beam powder bed fusion and laser powder bed fusion, respectively. These alloys, commonly used in implantology, here in the form of Ti block scaffolds, have been exposed to an Er3+:YAG laser under various parameters (energy range of 50–320 mJ, exposure times of 20 or 30 s), and their effects have been further observed. To determine the changes induced by the laser, the following techniques were used: X-ray diffraction (XRD), Rietveld refinement method, scanning electron microscopy (SEM) with EDS (Energy-dispersive X-ray Spectroscopy), and thermography. The results show that the proposed Ti6Al4V and Ti6Al7Nb scaffolds can be exposed to an Er3+:YAG laser without damage when the power is limited to 0.5 W.

21 June 2026 in Virtual and Physical Prototyping
Verified
Journal Article
Open access
EKEnjy Katary
Enjy Katary
KSKinga Sekuła
Kinga Sekuła
DKDawid Krok
Dawid Krok
MPMarcin Posmyk
Marcin Posmyk
MDMichał Dusza
Michał Dusza
KGKonrad Gruber
Konrad Gruber

2 December 2024 in Bio-Algorithms and Med-Systems
Verified
Journal Article
Closed access
Patrycja Szymczyk-ZiółkowskaPatrycja Szymczyk-Ziółkowska
Patrycja Szymczyk-Ziółkowska
MRMałgorzata Rusińska
Małgorzata Rusińska
Grzegorz ZiółkowskiGrzegorz Ziółkowski
Grzegorz Ziółkowski
KKKarol Kobiela
Karol Kobiela
KSKinga Sekuła
Kinga Sekuła
AMAnna Miner-Kordasiewicz
Anna Miner-Kordasiewicz
Objective: Maxillofacial injuries often necessitate complex reconstructive surgeries, requiring the design and fabrication of patient-specific implants (PSIs) to restore functionality and aesthetics. A 32-year-old male patient, who sustained a mandible injury, served as a case study.Methods: This study presents advancements in maxillofacial reconstruction through the application of Electron Beam Powder Bed Fusion (PBF-EB/M), an additive manufacturing (AM) technique, in the creation of personalized jaw implants. CT scans were processed to develop a 3-D model of the patient's tissues, and Finite Element Analysis (FEA) was employed to assess mechanical behaviour. Results: The PSI, manufactured from a Ti6Al4V ELI alloy, exhibited suitable mechanical properties and biocompatibility. This work presents a workflow that clarifies the principles of designing, verifying and manufacturing PSIs for maxillofacial reconstruction. Conclusions: By integrating advanced imaging techniques, FEA simulations, and AM technologies, along with post-processing using CAM tools, the feasibility of producing personalized medical devices with modern manufacturing methods that offer enhanced design flexibility can be assessed. This includes highlighting both the potential benefits and challenges of the proposed approach.