Recent improvements in laser ablation and multicollector (MC)-ICP-MS technology offer higher sensitivity, robust stability, and larger dynamic ranges. Such advances are translated into improved accuracy and precision on U–Pb age determinations, reduced spot sizes for high spatial resolution and reliable corrections for any amount of common Pb (Pbc). Although a number of studies have focused on the high-spatial resolution of the LA-MC-ICP-MS method, comparatively fewer experiments have explored the precision and stability of multi-collector instruments for high-precision U–Pb geochronology. In this contribution, we describe the precision and accuracy of Pbc corrected U–Pb ages obtained by LA-MC-ICP-MS, and discuss the homogeneity of two batches of zircon megacrystals (the Rio do Peixe (RP) and Blue Berry (BB)) as potential reference materials. The enhanced sensitivity and stability of the LA-MC-ICP-MS system allowed the determination of apparent Pb/U and Pb/Pb ratios with uncertainties of 0.3 to 1% (2s) for nearly all reference materials available. The measurements are done in automated mode, with a spatial resolution of 20 μm-wide spots. The short- and long-term reproducibility of 206Pb/238U, 207Pb/235U and 207Pb/206Pb ratios were assessed based on several reference materials, including GJ-1 (96 analyses), M125 (96 analyses), Temora (34 analyses), 91500 (29 analyses), FC-1 (17 analyses), BB (121 analyses) and Plešovice (133 analyses). The results show that the accuracy and precision of the relevant ratios are often between 0.5 and 1.0% (RSD). U–Pb LA-MC-ICP-MS and TIMS dates of four new megacrystals of the BB zircons agreed within error at ca. 560 ± 1 Ma, and demonstrate that they constitute suitable reference materials for LA-ICP-MS analyses. U–Pb LA-MC-ICP-MS for the RP zircons revealed low concentrations of U and Pb and a scattering of ages from 580 to 600 Ma (mean of 593 ± 5 Ma). The RP zircons may only be suitable as a quality control reference material.
17 October 2017 in Geostandards and Geoanalytical Research
This study investigates five megacrysts of xenotime (XN01, XN02, XN03, XN04, and XN05) as potential reference materials (RMs) for U‐Pb geochronology. These crystals belong to a 300 g xenotime assortment, collected from alluvial deposits in SE Brazil. Electron microprobe and Laser Ablation‐Inductively Coupled Plasma‐Mass Spectrometry (LA‐ICP‐MS) analyses show that the selected crystals are internally homogeneous for most rare earth element, (REE, except some light REE) but are relatively heterogeneous for U and Th. The xenotime REE patterns are consistent with an origin from hydrothermal quartz veins in the Datas area that cut greenschist‐facies metasediments and that locally contain other accessory phases such as rutile and monazite. High‐precision U‐Pb Isotope Dilution‐Thermal Ionization Mass Spectrometry (ID‐TIMS) analyses showed slight age heterogeneity for the XN01 crystal not observed in the XN02 sample. The two crystals have slightly different average 206Pb/238U ages of 513.4 ± 0.5 Ma (2 s) and 515.4 ± 0.2 Ma (2 s), respectively. In situ U‐Pb isotope data acquired via LA‐(Q,SF,MC)‐ICP‐MS are within the uncertainty of the ID‐TIMS data, showing homogeneity at the 1% precision of the laser ablation (and probably ion microprobe) technique. U‐Pb LA‐(MC, SF)‐ICP‐MS analyses, using XN01 as a primary RM, reproduced the ages of other established RMs within less than 1% deviation. Other Datas crystals (XN03‐05) also display a reproducibility in Pb/U dates better than 1% on LA‐ICP‐MS, making them good candidates for further testing by ID‐TIMS.