Background: There are only limited data on patients with diabetes undergoing transcatheter edge-to-edge repair (TEER) in real-world settings. Previous data indicated patients with diabetes to have a worse prognosis. This study sought to evaluate safety and efficacy of TEER in patients with diabetes in a real-world cohort. Methods: In this monocentric study 340 consecutive patients with severe primary and secondary mitral regurgitation (MR) undergoing TEER were included. Immediate results of the procedure, intrahospital and one-year outcome were compared between patients with and without diabetes. Results: Diabetes was present in 109 patients (32%). Patients with diabetes were younger (77 y (71, 81) vs. 79 y (74, 83); p = 0.003), had more often ischemic cardiomyopathy (68% vs. 48%; p<0.001), previous coronary-artery bypass graft (35% vs. 20%; p = 0.002) and arterial hypertension (89% vs. 75%; p<0.001) compared to those without diabetes. Baseline NYHA class, type of MR (primary vs. secondary), left ventricular dimensions and function (ejection fraction: 37% (28, 50) vs. 40% (29, 55); p = 0.10) as well as severity of MR were not different between both groups. Success of the procedure (95% vs. 95%; p = 0.84), intrahospital mortality (5.5% vs. 4.8%; p = 0.98) and one-year follow-up regarding all-cause mortality (24.2% vs. 23.0%; p = 0.72), hospitalization for heart failure (37.4% vs. 31.0%, p = 0.23), NYHA class (p = 0.14) or MR severity (p = 0.59) did not differ between both groups. Conclusion: Our real-world data suggest that TEER seems to be similarly safe and effective in patients with severe MR and diabetes compared to those without diabetes.
Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in comparison to cardiovascular magnetic resonance (CMR). 129 consecutive patients with standard TTE and RV analysis by CMR were included. A formula based on the geometric assumptions of a truncated cone minus a truncated rhomboid pyramid was developed for calculations of RV end-diastolic volume (EDV) and RV end-systolic volume (ESV) by using the basal diameter of the RV (Dd and Ds) and the baso-apical length (Ld and Ls) in apical 4-chamber TTE views: RV EDV = 1.21 * Dd2 * Ld, and RV ESV = 1.21 * Ds2 * Ls. Calculations of RV EDV (ΔRV EDV = 10.2±26.4 ml to CMR, r = 0.889), RV ESV (ΔRV ESV = 4.5±18.4 ml to CMR, r = 0.921) and RV EF (ΔRV EF = 0.5±4.0% to CMR, r = 0.905) with the cone-pyramid formula (CPF) highly agreed with CMR. Impaired RV function on CMR (n = 52) was identified with a trend to higher accuracy by CPF than by conventional echocardiographic parameters (tricuspid annular plane systolic excursion (TAPSE) and fractional area change (FAC)). Calculations of RV volumes and RV function by 2D TTE with the newly developed CPF were in high concordance to measurements by CMR. Accuracy for detection of patients with reduced RV function were higher by the proposed 2D TTE CPF method than by conventional echocardiographic parameters of TAPSE and RV FAC.
4 January 2022 in The International Journal of Cardiovascular Imaging
TMVR using different clip sizes is a treatment option for selected patients with mitral regurgitation (MR). This study sought to identify predictors of successful transcatheter mitral valve repair (TMVR) by 3-dimensional (3D) echocardiography and to compare different effects of the larger XTR and the smaller NT/NTR devices. 3D transesophageal echocardiography was performed on 54 patients with secondary MR undergoing TMVR with one clip (55.6% NT/NTR, 44.4% XTR). All NT/NTR and 96% of XTR patients had MR reduction ≤ 2+. Despite more severe baseline MR (3D vena contracta area (VCA): 0.67 ± 0.34 cm2 vs. 0.43 ± 0.19 cm2, p = 0.004) and greater mitral valve area (MVA) (6.8 ± 2.1 cm2 vs. 5.1 ± 1.6 cm2, p = 0.001) in the XTR group, MR severity after TMVR was not different between XTR and NT/NTR patients (3D VCA: 0.19 ± 0.14 vs. 0.17 ± 0.10, p = 0.51). Baseline 3D VCA > 0.45 cm2 in NT/NTR (AUC = 0.802, 95% CI 0.602 to 1.000) and 3D VCA > 0.54 cm2 in XTR devices (AUC = 0.868, 95% CI 0.719 to 1.000) were associated with ineffective MR reduction defined as residual VCA ≤ 0.2 cm2. Baseline MVA ≤ 4.2 cm2 in NT/NTR (AUC = 0.920, 95% CI 0.809 to 1.000) and MVA ≤ 6.0 cm2 in XTR devices (AUC = 0.865, 95% CI 0.664 to 1.000) were associated with postprocedural transmitral pressure gradient (TMPG) ≥ 5 mmHg. TMVR using the XTR device resulted in an equally effective reduction of MR despite of a greater baseline MR. Distinct cut-off values of baseline 3D VCA and MVA for prediction of successful MR reduction and postprocedural increase of TMPG were identified for the different devices.
Background/Objective: Cardiac magnetic resonance (CMR) is the reference method for right ventricular (RV) volume and function analysis, but time-consuming manual segmentation and corrections of imperfect automatic segmentations are needed. This study sought to evaluate the applicability of an echocardiographically established truncated cone–rhomboid pyramid formula (CPF) for simplified RV quantification using CMR. Methods: A total of 70 consecutive patients assigned to RV analysis using CMR were included. As standard method, the manual contouring of RV-short axis planes was performed for the measurement of end-diastolic volume (EDV) and end-systolic volume (ESV). Additionally, two linear measurements in four-chamber views were obtained in systole and diastole: basal diameters at the level of tricuspid valve (Dd and Ds) and baso-apical lengths from the center of tricuspid valve to the RV apex (Ld and Ls) were measured for the calculation of RV-EDV = 1.21 × Dd2 × Ld and RV-ESV = 1.21 × Ds 2 × Ls using CPF. Results: RV volumes using CPF were slightly higher than those using standard CMR analysis (RV-EDV index: 86.2 ± 29.4 mL/m2 and RV-ESV index: 51.5 ± 22.5 mL/m2 vs. RV-EDV index: 81.7 ± 24.1 mL/m2 and RV-ESV index: 44.5 ± 23.2 mL/m2) and RV-EF was lower (RV-EF: 41.1 ± 13.5% vs. 48.4 ± 13.7%). Both methods had a strong correlation of RV volumes (ΔRV-EDV index = −4.5 ± 19.0 mL/m2; r = 0.765, p < 0.0001; ΔRV-ESV index = −7.0 ± 14.4 mL/m2; r = 0.801, p < 0.0001). Conclusions: Calculations of RV volumes and function using CPF assuming the geometrical model of a truncated cone–rhomboid pyramid anatomy of RV is feasible, with a strong correlation to measurements using standard CMR analysis, and only two systolic and diastolic linear measurements in four-chamber views are needed.