Xinyu Dou

Dr. Xinyu Dou

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2018 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
XDXinyu Dou
Xinyu Dou
HLHuaqing Liang
Huaqing Liang
YLYang Liu
Yang Liu
Conventional adjacent wells range scanning calculations cannot meet the accuracy demands of the anticollision measurement of borehole distances any longer. Current techniques commonly employ electromagnetic detection tools while drilling; this requires putting equipment down adjacent wells to avoid collision risks, which adds more workload and costs and sometimes even affects the normal production of the producing wells. Measuring and tracking adjacent borehole distances while drilling is an essential process that guides the drill bit and effectively avoids collisions with existing wells. This paper proposes an active anticollision method of rotating magnetic ranging based on double symmetrical magnetic sources with opposite magnetic moments. First, the proposed method uses magnetic sources in the drilling well that are built into the probe tube to generate a magnetic field; then, the ferromagnetic casing of the existing well would be magnetized by the abovementioned magnetic field; finally, the magnetization field of the ferromagnetic casing is measured by a triaxial magnetometer built into the probe tube to determine the spacing and position of the existing well. Simultaneously, the calculation models of magnetic flux density around the casing of the existing well and magnetic sources are established, the calculation formulae of the relative distance and position of two adjacent wells are deduced, and a new variable interval section segmentation is proposed based on the Cosine theorem. The simulation results demonstrate that the spacing and position of the existing well are determined based on the magnetic sources’ spacing inside the probe, the magnetic moment of the magnetic sources, the relative permeability of the casing, the diameter of the casing, and the inclination between the drilling well and the existing well. The validity and accuracy of the active magnetization model are confirmed, providing theoretical support for the further development of electromagnetic anticollision devices.

30 April 2018 in IETE Journal of Research
Verified
Journal Article
Closed access
XDXinyu Dou
Xinyu Dou
HLHuaqing Liang
Huaqing Liang
To establish a tradeoff between complexity and performance of frequency estimation of sinusoidal signals, a novel automatic segmentation-improved Quinn–Rife method is proposed. The proposed method first utilizes a Discrete Fourier Transform (DFT) algorithm to obtain a coarse estimation, and then divides the frequency deviation into three domains with different processing schemes, which could be suitable for low-delay applications. Simulation results show that the proposed method can overcome the inherent flaws of the classic Quinn and Rife methods, and that the root mean square error closely approaches the Cramer–Rao lower bound at a low signal-to-noise ratio with different estimation ranges. Furthermore, the method does not significantly increase the computational cost under the premise of guaranteed performance, which is beneficial for engineering applications.

1 July 2008
Verified
Conference Paper
Closed access
TFTao Feng
Tao Feng
JCJian Cai
Jian Cai
HKHenri H.K. Kwon
Henri H.K. Kwon
QWQian Wang
Qian Wang
XDXinyu Dou
Xinyu Dou
Wafer level packaging (WLP) technology has been used to integrate high-Q inductor on Si substrate. These inductors consist of a thick Cu electroplated rerouting to reduce series resistance and a thick dielectric layer to separate the inductors from Si substrate. The measured results show that the peak O-factor is 30 at 4 GHz for a 0.77 nH inductor, which is good agreement with the simulated performance by HFSS. Therefore, this technology realizes embedded high-Q inductors in WLP and can improve the performance of RF system.

1 August 2009
Verified
Conference Paper
Closed access
NWNa Wang
Na Wang
JCJian Cai
Jian Cai
WYWeikang Yang
Weikang Yang
XDXinyu Dou
Xinyu Dou
A new package structure based on printed circuit board (PCB) as carrier substrate was proposed, aiming at providing an implementation of system-in package (SiP) emphasizing small size and more importantly low cost. This structure is built upon a multilayer PCB, where open cavities are created in the top and bottom layers to house active dies, allowing package size reduction as well as protection against handling and impact. An application prototype was devised to integrate an RF IC and a baseband digital IC, typical of a wireless communication Rx system. Thermo-mechanical simulation models of the prototype are constructed to comparably assess certain aspects of its reliability and manufacturability. The results show comparable thermal performance compared with currently mainstream substrate material. Thermal cycling test of the new structure to experimentally evaluate its reliability is planned with results to be reported in a separate report.

21 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XDXinyu Dou
Xinyu Dou
XYXiaoping Yan
Xiaoping Yan
LHLongyu Hu
Longyu Hu
HLHuaqing Liang
Huaqing Liang
Based on a comprehensive analysis of the existing methods for measuring adjacent well distances, along with their advantages and disadvantages, this study employs theoretical analysis, simulation experiments, and other comprehensive research methods to investigate a distance measurement method based on current excitation. In response to the need for measuring and controlling the connection of relief wells, a method utilizing dual-electrode current excitation during drilling is proposed. This approach facilitates synchronous excitation measurements while drilling, significantly reducing both time and costs while ensuring safety and efficiency, making it particularly suitable for the connection operation of relief wells that involve safety risks. Firstly, this paper establishes a drilling with measurement model corresponding to the excitation mode, which derives the calculation formulas for the target casing current amplitude attenuation, as well as the induced magnetic field distribution within the formation. Additionally, it provides the calculation methods for determining the target well distance and azimuth direction. Lastly, the impact levels of various key factors are verified through numerical calculations and simulation analyses, which confirm the correctness and effectiveness of this distance measurement method. The findings from this research establish both a core theoretical foundation and a technological basis for the real-time measurement of adjacent well distances during relief well operations.

18 November 2025 in Magnetochemistry
Verified
Journal Article
Open access
PDF file
PXPengfei Xu
Pengfei Xu
JZJichang Zhang
Jichang Zhang
JZJie Zeng
Jie Zeng
YWYulin Wang
Yulin Wang
XDXinyu Dou
Xinyu Dou
CWChengbo Wang
Chengbo Wang
Oxygen-enhanced magnetic resonance imaging (OE-MRI) enables non-invasive assessment of lung function by measuring longitudinal relaxation time (T1) changes induced by alternating inhalation of room air and pure oxygen. In this study, the pulmonary T1 and its reduction after breathing pure oxygen were quantified by using the free-breathing three-dimensional (3D) Look-Locker technique based on a stack-of-stars acquisition scheme. This method applied a continuous acquisition model to collect signals during both room-air and pure oxygen conditions without the need for breath-holding or respiratory gating. Comparative evaluations were conducted between the proposed 3D Look-Locker method and the conventional two-dimensional (2D) Look-Locker approach, using both phantom and in vivo experiments. The results demonstrate that the 3D technique yields more pronounced and reproducible T1 reductions between air and oxygen conditions compared to the 2D method. Additionally, the T1 of the average respiratory phase obtained by the 3D approach was compared with the T1 at end-expiration and end-inspiration measured by the 2D approach. A consistent decline in T1 across respiratory phases was demonstrated, from end-expiration to end-inspiration, as well as the average respiratory phase under free-breathing. These findings suggest that the proposed OE-MRI T1 measurement based on the 3D Look-Locker method provides a robust and clinically feasible approach for quantitative lung imaging.