Aarthi Sekaran

Dr. Aarthi Sekaran

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2024 in Education Sciences
Verified
Journal Article
Open access
PDF file
ASAarthi Sekaran
Aarthi Sekaran
Carolyn M RodakCarolyn M Rodak
Carolyn M Rodak
Fluid mechanics, a required course in many undergraduate engineering disciplines, is often described as a challenging subject as it weaves together advanced mathematics and physics to solve conventional engineering problems. This study examines the effect of incorporating a physical model project via multidisciplinary teams into two theory-based fluid mechanics courses to address two general questions: Does the design and construction of the physical model aid in understanding fluid mechanics concepts? Does working with students of different engineering disciplines improve student experience and comprehension? The study was conducted in Spring 2023 with a cohort of 49 mechanical and civil engineering students; each project team had a mix of both disciplines. At the end of the semester, all projects were presented at a common venue, followed by an anonymous paper-based survey. The results indicate that around 83.7% of students felt the project had an overall positive impact on their learning experience. Despite initial student apprehension about multidisciplinary teams, 72% of students appreciated the opportunity to work with engineers from other disciplines, with qualitative inputs describing the value added from varied skill sets. In conclusion, this project enabled students to apply their in-class training to a real-world model while working in multidisciplinary teams. The results provide insight into the implementation of similar projects and the value of multidisciplinary teams.

28 November 2025 in Fluids
Verified
Journal Article
Open access
PDF file
ASAarthi Sekaran
Aarthi Sekaran
AAAhmed Abdelaal
Ahmed Abdelaal
The increased incidence of respiratory diseases in the recent past has resulted in a growing number of respiratory failures and dependence on mechanical ventilation. The death rates in patients under long-term ventilator therapy are seen to be as high as 62%, with mortality often attributed to secondary bacterial infections originating in endotracheal tube (ETT) assemblies. The ETT connects the ventilator to the trachea, and the parameters selected by the clinician play important roles in determining the airflow dynamics and mucus transport. This study considers the influence of ETT cuff geometry and ventilator cycling on tracheal airflow behavior, comparing Taperguard- and Microcuff-type designs with respect to Pressure-Controlled Ventilation (PCV) and Assisted Volume-Controlled Ventilation (VCV) modes. Three-dimensional Unsteady Reynolds Averaged Navier–Stokes (URANS) simulations in an idealized intubated trachea were performed and complemented by flow visualization and flow rate measurements for model validation. The simulation results show that both the cuff geometry and ventilation mode affect flow asymmetry of air flow in the trachea and consequently the wall shear stresses and secondary flow development. Specifically, the Taperguard-style cuff under PCV conditions generated substantially elevated wall shear stress values—nearly twice those observed for the same cuff operating in VCV mode. In contrast, the Microcuff configuration paired with VCV produced lower gas flow velocities and reduced shear stress levels, reaching only about 80% of the peak values associated with the Taperguard case. These differences highlight the combined influence of cuff geometry and ventilation strategy on local airway loading. These findings highlight the coupled impact of cuff design and ventilatory mode, and provide a pathway for understanding flow physics in intubated trachea towards improved respiratory care and mechanical ventilation practices.

10 November 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PAPenny Andrews
Penny Andrews
ASAarthi Sekaran
Aarthi Sekaran
JAJoaquin Araos
Joaquin Araos
JSJosh Satalin
Josh Satalin
Gary F NiemanGary F Nieman
Gary F Nieman
NHNader M. Habashi
Nader M. Habashi
Acute respiratory distress syndrome (ARDS) remains a major clinical problem, and treatment is largely supportive with mechanical ventilation. When ventilator settings are poorly matched to lung physiology, ventilator-induced lung injury can occur and worsen outcomes. Two key features of ARDS limit the effectiveness of conventional ventilation strategies: (1) elevated pleural pressure (Ppl), particularly in dependent lung regions, and (2) time- and pressure-dependent (T-PD) mechanics, in which injured lung units open slowly but collapse quickly at any given airway pressure. These features may limit the effectiveness of standardized approaches such as ARDS Network low tidal volume ventilation, which was not designed to adapt to high Ppl or T-PD dynamics. Airway pressure release ventilation (APRV) has shown promising results in animal studies, meta-analyses, computational models, and small clinical trials, although no large multicenter randomized controlled trial has yet to demonstrate a mortality benefit. APRV can be individualized to evolving lung pathology using the time-controlled adaptive ventilation (TCAV) method. TCAV is designed to address elevated Ppl through a prolonged inspiratory phase (THigh) that enables viscoelastic recruitment by creep, and a brief expiratory release (TLow) that prevents the newly opened alveoli from re-collapsing. Recruitment may be further facilitated by transient airway pressure perturbations generated at the collision of inspiratory and expiratory gas flow (the “gas hammer” hypothesis). Recruitment first occurs in areas with low Ppl, such that transpulmonary pressure (PTP) is positive. Lung tissue recruitment reduces the mass load from edema and atelectasis, progressively lowering Ppl and resulting in a positive PTP. Gradually decreasing Ppl from nondependent to dependent regions as the lung recruits modifies the airway pressure gradient, allowing the entire lung to be gradually reopened. The TLow is personalized using the slope of the expiratory flow curve, providing a real-time indicator of respiratory system compliance and mechanical behavior analogous to passive spirometry. The TCAV method supports progressive recruitment within T-PD lung regions, gradually reducing Ppl, increasing PTP, and promoting more homogeneous ventilation distribution across the injured lung.

8 November 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASAarthi Sekaran
Aarthi Sekaran
ABAdel Bougatef
Adel Bougatef
Gary F NiemanGary F Nieman
Gary F Nieman
Acute respiratory distress syndrome (ARDS) imposes regionally heterogeneous, time-dependent alterations in pulmonary mechanics that fundamentally limit conventional ventilation strategies. Fixed-parameter approaches targeting global pressure, volume, or timing thresholds cannot simultaneously address the competing demands of alveolar recruitment and volutrauma prevention, nor can they adapt dynamically to the wide regional variation in compliance, resistance, and expiratory time constants that characterizes the injured lung. These limitations persist across volume-controlled, pressure-controlled, high-frequency oscillatory, and time-controlled ventilation strategies. This article provides a clinically oriented narrative review of the physiologic and fluid-dynamic principles underlying Adaptive Dynamic Subtidal Ventilation (ADSV), an emerging ventilation technology that incorporates a proximal airway device—the Sliding Venturi—that passively modulates subtidal gas delivery in response to evolving respiratory system mechanics. The device utilizes the Bernoulli and Venturi effects to establish a passive pressure–flow feedback mechanism in which downstream respiratory system mechanics influence gas entrainment, delivered subtidal volume, and airway pressure. In the low-compliance (high-elastance) ARDS lung, this may limit gas entrainment and subtidal volume delivery while maintaining distending pressure. As compliance improves, entrainment may increase, permitting larger subtidal volumes at lower pressures. This self-regulating behavior operates on millisecond timescales and adapts to changes in overall respiratory system mechanics. Patient-proximal placement facilitates rapid expiratory venting, potentially reducing circuit-related expiratory resistance and dynamic hyperinflation, although these effects require experimental validation. ADSV therefore provides a fluid-dynamic framework for mechanically responsive subtidal ventilation that may help manage the changing respiratory mechanics associated with ARDS. Bench and computational studies, followed by preclinical and clinical investigations, are needed to characterize device performance, evaluate regional physiological effects, and establish safety and efficacy in ARDS.