This research paper explores the visual potential of the multi-angled façade system, allowing office employees to achieve optimal exposure to the external environment through the room façade. This contributes to sustainability objectives by enhancing indoor climate quality, promoting health and well-being, and aligning with the UN Sustainable Development Goals 3, 9, and 11. This façade concept provides a solution to the issue of shading devices being fully closed for long periods due to intense solar radiation on the room’s window. The concept of a multi-angled window involves incorporating two differently oriented window sections within each façade along a vertical axis (right and left), rather than tilting them upward or downward. The larger section is oriented more toward the north to maximize daylight access and external views, while the smaller section faces south to enhance passive solar heating. The visual potential is assessed based on the periods when the solar shading devices are not fully closed—meaning one section of the multi-angled façade may remain open while the other is shaded. To evaluate this, along with the resulting energy consumption and indoor climate, the software program IDA ICE version 4.8 is utilized. Simulation results indicate that the duration of complete shading closure is significantly lower for a multi-angled façade compared to a flat façade, in some instances nearly half, thereby improving visual comfort, daylight availability, and heat gain while simultaneously reducing spatial energy consumption.
This research paper examines how multi-angled façade systems improve and optimise energy performance compared to a flat façade and meet sustainability targets for lower energy use to align with UN SDGs 3, 11, 12, and 13. The multi-angled façade system does not tilt up and down. Instead, it employs two different window orientations on a vertical axis (left and right). The large portion orients more to the north to allow more daylight to penetrate inside the room, and the small part is oriented more to the south to provide passive solar heating. The investigations in this research paper were carried out using version 4.8 of the IDA ICE software, and the researchers evaluated the energy consumption, the energy action through the façade, and the building’s inside operative temperature. The results of this paper present the simulation findings for primary energy consumption in different scenarios. For example, the researchers explain that one can save 6.3 kWh/(m2·year) when using a multi-angled façade system compared to a flat façade. This is in addition to improving the thermal indoor climate that results from using the façades. The conclusions of the research show that the façade with multiple angles maximises using daylight and optimises solar power, thus avoiding overheating issues.
This research paper optimises the configuration of multi-angled façade systems to achieve the sustainability goals of reduced energy consumption and improved indoor climate quality. The concept of a multi-angled façade system is based on proposing the use of two different orientations of windows in each façade on a vertical axis, but not tilted up and down. The large part of the multi-angled façade is oriented more to the north to optimise the use of daylight and the small part more to the south to optimise the use of solar radiation. In order to evaluate the performance of the façade, the software program IDA ICE version 4.8 is used. (EQUA, Stockholm, Sweden). Two groups of scenarios were simulated: the first group consisted of nine scenarios (A1 to A9) that included changing the area and the orientation of the two façade parts, and the second group consisted of three scenarios (B1 to B3) by changing the window to wall ratio (WWR) of these scenarios. According to the results of the simulation, two scenarios from the first group are recommended: A3 for optimal daylight penetration and A7 for optimal energy performance. Regarding the second group, scenarios B1 for optimal daylight penetration and B3 for optimal energy performance are recommended.