Shaharier Kabir

Mr. Shaharier Kabir

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2022 in Technology and Economics of Smart Grids and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
ASAbu Shufian
Abu Shufian
JHJawad-Al-Mursalin Hoque
Jawad-Al-Mursalin Hoque
SKShaharier Kabir
Shaharier Kabir
NMNur Mohammad
Nur Mohammad

15 November 2024 in Smart Grids and Sustainable Energy
Verified
Journal Article
Open access
PDF file
ASAbu Shufian
Abu Shufian
NHNasif Hannan
Nasif Hannan
SKShaharier Kabir
Shaharier Kabir
SFShaikh Anowarul Fattah
Shaikh Anowarul Fattah
The adoption of High Voltage Direct Current (HVDC) systems based on Modular Multilevel Converters (MMC) has grown significantly due to their modularity, scalability, and superior output voltage characteristics. Unlike traditional Voltage Source Converters (VSC) technology, MMC systems are unaffected by the characteristics of the connected AC power, allowing for greater flexibility in power network configurations. This article establishes a theoretical framework for MMC-HVDC systems, detailing the fundamental principles and mathematical models that govern their operation, along with control systems, harmonic analystis, specialized power system applications, and protection systems. The dynamic responses of system parameters are analyzed concerning inherent characteristics and operational constraints, with values systematically designed based on desired objectives. Additionally, with an active power of 1000 MW, the system exhibits nominal voltage values of 400 kV on the primary and 333 kV on the secondary side. The paper introduces a model to validate operational concepts and assess dynamics of the proposed system under various conditions, including steady-state, transient response, voltage, current regulation, active and reactive power. It also presents an innovative method that increases arm inductance to reduce Total Harmonic Distortion (THD) in arm currents. A key finding is the simultaneous adjustment of arm inductance (14 p.u.) and submodule (SM) capacitance (5.757 mF), which identifies an optimal condition resulting in the lowest THD (1.63%). This reduction in THD enhances power quality by minimizing harmonic distortions. The performance optimization provides valuable insights into the dynamic behavior and performance metrics of the system, offering critical assessments and strategies that can aid researchers and engineers in addressing challenges associated with MMC-HVDC systems, ultimately promoting their broader integration into smart grid infrastructures.

21 September 2023
Verified
Conference Paper
Closed access
SOShihab Sharar Oyon
Shihab Sharar Oyon
ASAbu Shufian
Abu Shufian
SKShaharier Kabir
Shaharier Kabir
AIAshikul Islam
Ashikul Islam
SMSaidur Rashid Mahin
Saidur Rashid Mahin
SMSaif Mahmud
Saif Mahmud
Due to the modernization of the power system, automatic monitoring, control, and protection are observed from electricity generation via transmission to the consumer end. Sometimes an unwanted fault occurs in power transmission lines, which breaks the uninterrupted electricity flow. Hence, a huge amount of power loss happens. This paper presents an in-depth study of three-phase failures in electrical power systems employing an overcurrent relay and a magnetic breaker. One of the most dangerous disruptions that can affect electricity systems is a three-phase failure, which can seriously harm machinery and endanger people's safety. The overcurrent relay and magnetic breaker are two common safeguards for spotting and isolating faults. With the combination of a thermal-magnetic circuit breaker and an overcurrent relay system, this research investigates three-phase fault automatic detection and protection. And examines how the magnetic breaker and overcurrent relay identify and stop faults, noting their benefits and drawbacks. The investigation offers important insights into the efficient use of magnetic breakers and overcurrent relays for improved fault detection and protection in electrical power systems.

17 May 2023
Verified
Conference Paper
Closed access
ASAbu Shufian
Abu Shufian
ZHZiad Hossain
Ziad Hossain
SMSoumitra Mazumder
Soumitra Mazumder
SKShaharier Kabir
Shaharier Kabir
SMSaidur Rashid Mahin
Saidur Rashid Mahin
NMNur Mohammad
Nur Mohammad

15 January 2025 in Research Square
Verified
Preprint
Open access
PDF file
SKShaharier Kabir
Shaharier Kabir
MCMehnaz Chowdhury
Mehnaz Chowdhury
SZSaniat Rahman Zishan
Saniat Rahman Zishan
Cyber-physical power systems (CPPS), such as smart grids, are increasingly vital to modern infrastructure but are also highly vulnerable to sophisticated cyber-attacks. Traditional security measures often detect these attacks only after significant damage has occurred, highlighting the need for proactive approaches that can identify potential threats before they fully manifest. This research presents a comprehensive investigation into the use of machine learning models for the early detection of cyber-attacks in a smart grid environment, with a particular focus on identifying pre-attack phases. We employed several unsupervised learning algorithms, including Isolation Forest, K-Means Clustering, DBSCAN, and One-Class SVM, to analyze a time series dataset that simulates normal operations and various attack scenarios. Among these models, Isolation Forest demonstrated superior performance, achieving an Area Under Curve (AUC) score of 1.0, accuracy of 100%, and a sensitivity of 100% in detecting anomalies. DBSCAN also performed well, with an AUC of 0.79 and accuracy of 97.3%, although it exhibited a slightly higher false positive rate compared to Isolation Forest. To detect pre-attack phases, we focused on the anomaly scores generated by the Isolation Forest model. By adjusting the sensitivity threshold, we identified periods of abnormal behavior that precede actual attacks. A threshold of 0.3 for anomaly scores provided a balanced detection, revealing multiple pre-attack phases while maintaining a low false positive rate. However, a higher threshold of 0.97, while reducing false positives, resulted in the detection of fewer pre-attack phases, indicating that the attacks may occur more abruptly without significant pre-attack indicators. These findings underscore the potential of machine learning models in enhancing the security of cyber-physical systems by not only detecting attacks but also providing early warnings through the identification of pre-attack phases. This proactive approach could significantly mitigate the impact of cyber-attacks on critical infrastructure, offering a valuable tool for cybersecurity professionals in safeguarding these systems.

16 October 2023
Verified
Conference Paper
Closed access
NUNuruzzaman
Nuruzzaman
KSKulojeet Kingshuk Sarker
Kulojeet Kingshuk Sarker
ASAbu Shufian
Abu Shufian
MHMd Sajid Hossain
Md Sajid Hossain
SKShaharier Kabir
Shaharier Kabir
AHAtm Rakibul Hassan Hemel
Atm Rakibul Hassan Hemel
Clean, accessible water is critical to human health, a healthy environment, peace, and security. The availability of safe drinking water supplies is a main concern for an overpopulated country like Bangladesh. A large proportion of the population of Bangladesh still does not have access to adequate, clean, and pure water. The scarcity of water poses a major threat to several areas of society, including food security. In this work, we will develop a coin-based water ATM system with ultra membrane filtration that will ensure the availability of pure, fresh, and safe drinking water for a large population at a low cost. Besides, adding GSM features will ensure easy maintenance and monitoring of the system. This device can be used in various crowded and public places like busy roads, highways, railway junctions, shopping malls, etc.