Enzyme-based portable amperometric biosensors are precise and low-cost medical devices used for rapid cancer biomarker screening. Sarcosine (Sar) is an ideal biomarker for prostate cancer (PCa). Because human serum and urine contain complex interfering substances that can directly oxidize at the electrode surface, rapid Sar screening biosensors are relatively challenging and have rarely been reported. Therefore, highly sensitive and selective amperometric biosensors that enable real-time measurements within <1.0 min are needed. To achieve this, a chitosan–polyaniline polymer nanocomposite (CS–PANI NC), a carrier for dispersing mesoporous carbon (MC), was synthesized and modified on a screen-printed carbon electrode (SPCE) to detect hydrogen peroxide (H2O2). The sarcosine oxidase (SOx) enzyme-immobilized CS–PANI–MC-2 ternary NCs were referred to as supramolecular architectures (SMAs). The excellent electron transfer ability of the SMA-modified SPCE (SMA/SPCE) sensor enabled highly sensitive H2O2 detection for immediate trace Sar biomarker detection. Therefore, the system included an SMA/SPCE coupled to a portable potentiostat linked to a smartphone for data acquisition. The high catalytic activity, porous architecture, and sufficient biocompatibility of CS–PANI–MC ternary NCs enabled bioactivity retention and immobilized SOx stability. The fabricated biosensor exhibited a detection limit of 0.077 μM and sensitivity of 8.09 μA mM−1 cm−2 toward Sar, demonstrating great potential for use in rapid PCa screening.
Disposable sensors are inexpensive, user-friendly sensing tools designed for rapid single-point measurements of a target. Disposable sensors have become more and more essential as diagnostic tools due to the growing demand for quick, easy-to-access, and reliable information related to the target. Dopamine (DA), a prevalent catecholamine neurotransmitter in the human brain, is associated with central nervous system activities and directly promotes neuronal communication. For the sensitive and selective estimation of DA, an enzyme-free amperometric sensor based on polyaniline-doped multi-walled carbon nanotubes (PANI-MWCNTs) drop-coated disposable screen-printed carbon electrodes (SPCEs) was fabricated. This PANI-MWCNTs-2/SPCE sensor boasts exceptional accuracy and sensitivity when working directly with ex vivo mouse brain homogenates. The sensor exhibited a detection limit of 0.05 μM (S/N = 3), and a wide linear range from 1.0 to 200 μM. The sensor’s high selectivity to DA amidst other endogenous interferents was recognized. Since the constructed sensor is enzyme-free yet biocompatible, it exhibited high stability in DA detection using ex vivo mouse brain homogenates extracted from both Parkinson’s disease and control mice models. This research thus presents new insights into understanding DA release dynamics at the tissue level in both of these models.
Melatonin (MT), a pineal gland hormone, regulates the sleep/wake cycle and is a potential biomarker for neurodegenerative disorders, depression, hypertension, and several cancers, including prostate cancer and hepatocarcinoma. The amperometric detection of MT was achieved using a sensor customized with ruthenium-incorporated carbon spheres (Ru–CS), possessing C- and O-rich catalytically active Ru surfaces. The non-covalent interactions and ion–molecule adducts between Ru and CS favor the formation of heterojunctions at the sensor–analyte interface, thus accelerating the reactions towards MT. The Ru–CS/Screen-printed carbon electrode (SPCE) sensor demonstrated the outstanding electrocatalytic oxidation of MT owing to its high surface area and heterogeneous rate constants and afforded a lower detection limit (0.27 μM), high sensitivity (0.85 μA μM −1 cm−2), and excellent selectivity for MT with the co-existence of crucial neurotransmitters, including norepinephrine, epinephrine, dopamine, and serotonin. High concentrations of active biomolecules, such as ascorbic acid and tyrosine, did not interfere with MT detection. The practical feasibility of the sensor for MT detection in pharmaceutical samples was demonstrated, comparable to the data provided on the product labels. The developed amperometric sensor is highly suitable for the quality control of medicines because of its low cost, simplicity, small sample size, speed of analysis, and potential for automation.
A novel electrochemical sensor based on Cu-loaded carbon nanospheres (Cu–CNSs) was designed and fabricated. Initially, the CNSs were synthesized using a natural or inexpensive carbon source (dark brown sugar), and Cu was loaded to enhance the electrocatalytic properties of the material. Subsequently, the synthesized Cu–CNSs were modified onto a screen-printed carbon electrode (SPCE), termed Cu–CNS/SPCE, to simultaneously detect the biomarkers dopamine (DA) and melatonin (MT) through differential pulse voltammetry. The surface characterization of the Cu–CNSs confirmed the formation of carbon spheres and Cu nanoparticles covering the spheres. Electrochemical studies showed that the Cu–CNS/SPCE had a high selectivity and sensitivity toward DA and MT, with a significant peak separation of 0.502 V. The two linear ranges of DA were 0.125–20 μM and 20–100 μM and the linear range of MT was 1.0–100 μM, with corresponding detection limits of 0.34 μM and 0.33 μM (S/N = 3), respectively. The quantification limits for DA and MT were 2.19 and 1.09 μM (S/N = 10), respectively. The sensor performance is attributed to the high conductivity and large, electrochemically active surface area of the Cu–CNS. In human serum samples, the Cu–CNS/SPCE exhibited good selectivity and satisfactory reproducibility for the simultaneous determination of DA and MT.
Electrochemical sensors are user-friendly devices designed for the rapid and straightforward detection of target analytes. Serotonin (5-hydroxytryptamine, 5-HT) is a key neurotransmitter and neuromodulator that regulates diverse neuronal processes. Using a custom-designed screen-printed carbon electrode (SPCE) incorporating ordered mesoporous carbon–bimetal oxides of Cu and Ni (CuO–NiO–OMC), rapid and real-time detection of 5-HT was achieved. The CuO–NiO–OMC structure featured highly active CuO and NiO catalytic sites that effectively promoted the irreversible oxidation of 5-HT (vs. Ag/AgCl reference electrode). The CuO–NiO–OMC/SPCE sensor, connected to a portable potentiostat, exhibited exceptional electrocatalytic performance for the oxidation of 5-HT, with a detection limit of 42.5 nM. The sensitivity was 1.56 A M−1 cm−2, and the linear dynamic range was 0.0–80.0 µM. The CuO–NiO–OMC/SPCE sensor also demonstrated outstanding selectivity in the presence of competing neurochemicals, including norepinephrine, epinephrine, dopamine, and glutamate, as well as high concentrations of tested biomolecules and inorganic ions. Furthermore, the practicality of the sensor was demonstrated using human serum and urine samples, with recovery percentages ranging from 91.1% to 98.3%. Thus, the CuO–NiO–OMC/SPCE sensor offers an effective approach for 5-HT sensing, thereby permitting molecular-level understanding of brain function.
Bacterial infections in marine fishes are linked to mass mortality issues; hence, rapid detection of an infection can contribute to achieving a faster diagnosis using point-of-care testing. There has been substantial interest in identifying diagnostic biomarkers that can be detected in major organs to predict bacterial infections. Aspartate was identified as an important biomarker for bacterial infection diagnosis in olive flounder (Paralichthys olivaceus) fish. To determine aspartate levels, an amperometric biosensor was designed based on bi-enzymes, namely, glutamate oxidase (GluOx) and aspartate transaminase (AST), which were physisorbed on copolymer reduced graphene oxide (P-rGO), referred to as enzyme nanosheets (GluOx-ASTENs). The GluOx-ASTENs were drop casted onto a Prussian blue electrodeposited screen-printed carbon electrode (PB/SPCE). The proposed biosensor was optimized by operating variables including the enzyme loading amount, coreactant (α-ketoglutarate) concentration, and pH. Under optimal conditions, the biosensor displayed the maximum current responses within 10 s at the low applied potential of −0.10 V vs. the internal Ag/AgCl reference. The biosensor exhibited a linear response from 1.0 to 2.0 mM of aspartate concentrations with a sensitivity of 0.8 µA mM−1 cm−2 and a lower detection limit of approximately 500 µM. Moreover, the biosensor possessed high reproducibility, good selectivity, and efficient storage stability.