Joseph Leach

Dr. Joseph Leach


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2010 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
JLJoseph Leach
Joseph Leach
VRVitaliy L. Rayz
Vitaliy L. Rayz
BSBruno Soares
Bruno Soares
MWMax Wintermark
Max Wintermark
MMMohammad R. K. Mofrad
Mohammad R. K. Mofrad
DSDavid Saloner
David Saloner
Atherosclerosis at the carotid bifurcation is a major risk factor for stroke. As mechanical forces may impact lesion stability, finite element studies have been conducted on models of diseased vessels to elucidate the effects of lesion characteristics on the stresses within plaque materials. It is hoped that patient-specific biomechanical analyses may serve clinically to assess the rupture potential for any particular lesion, allowing better stratification of patients into the most appropriate treatments. Due to a sparsity of in vivo plaque rupture data, the relationship between various mechanical descriptors such as stresses or strains and rupture vulnerability is incompletely known, and the patient-specific utility of biomechanical analyses is unclear. In this article, we present a comparison between carotid atheroma rupture observed in vivo and the plaque stress distribution from fluid–structure interaction analysis based on pre-rupture medical imaging. The effects of image resolution are explored and the calculated stress fields are shown to vary by as much as 50% with sub-pixel geometric uncertainty. Within these bounds, we find a region of pronounced elevation in stress within the fibrous plaque layer of the lesion with a location and extent corresponding to that of the observed site of plaque rupture.

11 October 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
MAM.R. Amans
M.R. Amans
HHH. Haraldsson
H. Haraldsson
EKE. Kao
E. Kao
SKS. Kefayati
S. Kefayati
KMK. Meisel
K. Meisel
DSD. Saloner
D. Saloner
BACKGROUND AND PURPOSE: Case reports demonstrate that coiling of a sigmoid sinus diverticulum can treat pulsatile tinnitus. We hypothesized that MR imaging 4D flow and computational fluid dynamics would reveal distinct blood flow patterns in the venous outflow tract in these patients. MATERIALS AND METHODS: Patients with pulsatile tinnitus of suspected venous etiology underwent MR imaging at 3T, using venous phase contrast-enhanced MR angiography, 4D flow, and 2D phase contrast. The contrast-enhanced MRA contours were evaluated to determine the presence and extent of a sigmoid sinus diverticulum. Computational fluid dynamics analysis was performed using the 4D flow inlet flow and the luminal contours from contrast-enhanced MRA as boundary conditions. In addition, computational fluid dynamics was performed for the expected post treatment conditions by smoothing the venous geometry to exclude the sigmoid sinus diverticulum from the anatomic boundary conditions. Streamlines were generated from the 4D flow and computational fluid dynamics velocity maps, and flow patterns were examined for the presence of rotational components. RESULTS: Twenty-five patients with pulsatile tinnitus of suspected venous etiology and 10 control subjects were enrolled. Five (20%) of the symptomatic subjects had sigmoid sinus diverticula, all associated with an upstream stenosis. In each of these patients, but none of the controls, a stenosis-related flow jet was directed toward the opening of the sigmoid sinus diverticulum with rotational flow patterns in the sigmoid sinus diverticulum and parent sigmoid sinus on both 4D flow and computational fluid dynamics. CONCLUSIONs: Consistent patterns of blood flow can be visualized in a sigmoid sinus diverticulum and the parent sinus using 4D flow and computational fluid dynamics. Strong components of rotational blood flow were seen in subjects with sigmoid sinus diverticula that were absent in controls.

25 April 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
HHH. Haraldsson
H. Haraldsson
JLJoseph Leach
Joseph Leach
EKE.I. Kao
E.I. Kao
AWA.G. Wright
A.G. Wright
SAS.G. Ammanuel
S.G. Ammanuel
MAM.R. Amans
M.R. Amans
BACKGROUND AND PURPOSE: Idiopathic intracranial hypertension is commonly associated with transverse sinus stenosis, a venous cause of pulsatile tinnitus. In patients with idiopathic intracranial hypertension, CSF drainage via lumbar puncture decreases intracranial pressure, which relieves the stenosis, and may provide at least temporary cessation of pulsatile tinnitus. The objective of this study was to evaluate changes in venous blood flow caused by lowered intracranial pressure in patients with pulsatile tinnitus to help identify the cause of pulsatile tinnitus. MATERIALS AND METHODS: Ten patients with suspected transverse sinus stenosis as a venous etiology for pulsatile tinnitus symptoms underwent MR imaging before and after lumbar puncture in the same session. The protocol included flow assessment and rating of pulsatile tinnitus intensity before and after lumbar puncture and MR venography before lumbar puncture. Post-lumbar puncture MR venography was performed in 1 subject. RESULTS: There was a lumbar puncture–induced reduction in venous peak velocity that correlated with the opening pressure (r = −0.72, P = .019) without a concomitant reduction in flow rate. Patients with flow jets had their peak velocity reduced by 0.30 ± 0.18 m/s (P = .002), correlating with a reduction in CSF pressure (r = 0.82, P = .024) and the reduction in subjectively scored pulsatile tinnitus intensity (r = 0.78, P = .023). The post-lumbar puncture MR venography demonstrated alleviation of the stenosis. CONCLUSIONS: Our results show a lumbar puncture–induced reduction in venous peak velocity without a concomitant reduction in flow rate. We hypothesize that the reduction is caused by the expansion of the stenosis after lumbar puncture. Our results further show a correlation between the peak velocity and pulsatile tinnitus intensity, suggesting the flow jet to be instrumental in the development of sound.

13 September 2009 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
JLJoseph Leach
Joseph Leach
VRVitaliy L. Rayz
Vitaliy L. Rayz
MMMohammad R. K. Mofrad
Mohammad R. K. Mofrad
DSDavid Saloner
David Saloner
Patient-specific biomechanical modeling of atherosclerotic arteries has the potential to aid clinicians in characterizing lesions and determining optimal treatment plans. To attain high levels of accuracy, recent models use medical imaging data to determine plaque component boundaries in three dimensions, and fluid–structure interaction is used to capture mechanical loading of the diseased vessel. As the plaque components and vessel wall are often highly complex in shape, constructing a suitable structured computational mesh is very challenging and can require a great deal of time. Models based on unstructured computational meshes require relatively less time to construct and are capable of accurately representing plaque components in three dimensions. These models unfortunately require additional computational resources and computing time for accurate and meaningful results. A two-stage modeling strategy based on unstructured computational meshes is proposed to achieve a reasonable balance between meshing difficulty and computational resource and time demand. In this method, a coarsegrained simulation of the full arterial domain is used to guide and constrain a fine-scale simulation of a smaller region of interest within the full domain. Results for a patient-specific carotid bifurcation model demonstrate that the two-stage approach can afford a large savings in both time for mesh generation and time and resources needed for computation. The effects of solid and fluid domain truncation were explored, and were shown to minimally affect accuracy of the stress fields predicted with the two-stage approach.

31 July 2019 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
JLJoseph Leach
Joseph Leach
EKEvan Kao
Evan Kao
Chengcheng ZhuChengcheng Zhu
Chengcheng Zhu
DSDavid Saloner
David Saloner
MHMichael D. Hope
Michael D. Hope
Intraluminal thrombus (ILT) is present in the majority of abdominal aortic aneurysms (AAA) of a size warranting consideration for surgical or endovascular intervention. The rupture risk of AAAs is thought to be related to the balance of vessel wall strength and the mechanical stress caused by systemic blood pressure. Previous finite element analyses of AAAs have shown that ILT can reduce and homogenize aneurysm wall stress. These works have largely considered ILT to be homogeneous in mechanical character or have idealized a stiffness distribution through the thrombus thickness. In this work, we use magnetic resonance imaging (MRI) to delineate the heterogeneous composition of ILT in 7 AAAs and perform patient–specific finite element analysis under multiple conditions of ILT layer stiffness disparity. We find that explicit incorporation of ILT heterogeneity in the finite element analysis is unlikely to substantially alter major stress analysis predictions regarding aneurysm rupture risk in comparison to models assuming a homogenous thrombus, provided that the maximal ILT stiffness is the same between models. Our results also show that under a homogeneous ILT assumption, the choice of ILT stiffness from values common in the literature can result in significantly larger variations in stress predictions compared to the effects of thrombus heterogeneity.

1 February 2021 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
JLJoseph Leach
Joseph Leach
Chengcheng ZhuChengcheng Zhu
Chengcheng Zhu
DMDimitrios Mitsouras
Dimitrios Mitsouras
DSDavid Saloner
David Saloner
MHMichael D. Hope
Michael D. Hope
Accurate and reproducible measurement of abdominal aortic aneurysm (AAA) size is an essential component of patient management, and most reliably performed at CT using a multiplanar reformat (MPR) strategy. This approach is not universal, however. This study aims to characterize the measurement error present in routine clinical assessment of AAAs and the potential clinical ramifications. Patients were included if they had AAA assessed by CT and/or MRI at two time points at least 6 months apart. Clinical maximal AAA diameter, assessed by non-standardized methods, was abstracted from the radiology report at each time point and compared to the reference aneurysm diameter measured using a MPR strategy. Discrepancies between clinical and reference diameters, and associated aneurysm enlargement rates were analyzed. Two hundred thirty patients were included, with average follow-up 3.3±2.5 years. When compared to MPR-derived diameters, clinical aneurysm measurement inaccuracy was, on average, 3.3 mm. Broad limits of agreement were found for both clinical diameters [−6.7 to +6.5 mm] and aneurysm enlargement rates [−4.6 to +4.2 mm/year] when compared to MPR-based measures. Of 78 AAAs measuring 5–6 cm by the MPR method, 21 (26.9%) were misclassified by the clinical measurement with respect to a common repair threshold (5.5 cm), of which 5 were misclassified as below, and 16 were misclassified as above the threshold. The clinical use of non-standardized AAA measurement strategies can lead to incorrect classification of AAAs as larger or smaller than the commonly accepted repair threshold of 5.5 cm and can induce large errors in quantification of aneurysm enlargement rate.