Kangkang Zhang

Dr. Kangkang Zhang

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2025 in Energy
Verified
Journal Article
Closed access
DWDong Wang
Dong Wang
RZRongrong Zhou
Rongrong Zhou
ZSZiyi Sun
Ziyi Sun
KZKangkang Zhang
Kangkang Zhang
JLJinli Lu
Jinli Lu
JJJie Ji
Jie Ji

16 October 2025 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
KZKangkang Zhang
Kangkang Zhang
QLQian Lu
Qian Lu
YHYuge Han
Yuge Han
DRDengfeng Ren
Dengfeng Ren
CZChenguang Zhu
Chenguang Zhu
DWDong Wang
Dong Wang

12 November 2025 in Fuel
Verified
Journal Article
Closed access
KZKangkang Zhang
Kangkang Zhang
QLQian Lu
Qian Lu
RZRongrong Zhou
Rongrong Zhou
YHYuge Han
Yuge Han
DRDengfeng Ren
Dengfeng Ren
DWDong Wang
Dong Wang

28 June 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
SDSensen Deng
Sensen Deng
DWDong Wang
Dong Wang
KZKangkang Zhang
Kangkang Zhang
MLMengxue Li
Mengxue Li
YLYuehong Lu
Yuehong Lu
In this paper, a novel central air-conditioning system with an internal heat exchanger is proposed and analyzed for its energy-saving effect. Two frequently used systems are chosen as the reference systems, i.e., a conventional system with a sensible heat exchanger (Reference System I) and a conventional system with a total heat exchanger (Reference System II). Analysis models are built to simulate the performance of the system. The energy-saving effects of the proposed system and the two reference systems under different conditions are theoretically calculated using a case-studied shopping mall in Nanjing, China. The results show that the influence of indoor relative humidity (RH) on the energy-saving effect is much greater than that of the indoor design temperature. Indoor design parameters have a greater impact on energy saving than outdoor design parameters. Under the studied conditions, the maximum energy-saving rates of the proposed system, Reference System I, and Reference System II, are 52.7%, 2.3%, and 12.1%, respectively. With the decrease in fresh-air ratio from 70% to 20%, the difference in energy-saving rates between the proposed system and Reference System II (Reference System I) can increase from 5% to 23% (15% to 30%). Therefore, the proposed system has obvious energy-saving potential and advantage, especially under the condition of a lower fresh-air ratio.

22 May 2026 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
KZKangkang Zhang
Kangkang Zhang
QLQian Lu
Qian Lu
SDSheng Ding
Sheng Ding
DWDong Wang
Dong Wang
YHYuge Han
Yuge Han
JXJiankai Xue
Jiankai Xue

27 August 2026 in Geoenergy Science and Engineering
Verified
Journal Article
Closed access
CWChanglong Wang
Changlong Wang
XXXiaolei Xu
Xiaolei Xu
DWDong Wang
Dong Wang
KZKangkang Zhang
Kangkang Zhang
JLJinli Lu
Jinli Lu
XHXinjie Huang
Xinjie Huang