This paper deals with the development of an accurate finite-element model of an arrester to investigate the electrothermal and mechanical stress during dc current interruption. The comprehensive analysis performed on a ZnO surge arrester is supported by experiments during high-voltage dc circuit breaker current interruption. The performed experimental analysis comprises three sequential 26 kV/10 kA direct current interruption tests carried out within a period of one hour. The dynamic temperature and current distribution of the surge arrester columns during current interruption are measured. The finite-element simulation results are in good agreement with the test results. The influence of the surge arrester temperature on the current distribution among the surge arrester columns is analyzed. The impact of the surge arrester temperature on ZnO electrical characteristics and mechanical stress inside the surge arrester are also investigated. The surge arrester finite-element model can be used with full success for parameter optimization of the surge arresters to prevent possible failures when dc circuit breakers performed multiple interruptions in short period of time.
DC circuit breakers (DCCBs) are the key equipment to rapidly interrupt the fault current in high-voltage DC power grids and ensure the safe operation of the system. However, most DCCBs do not take current-limiting measures and rely solely on current-limiting reactors in the system to limit the rate of current rise during the interruption process. The extensive use of fully controlled power electronic devices in circuit breakers (CBs) results in high costs. To address the issues above, this paper proposes a DCCB topology with a current-limiting function based on thyristors and diodes, which can reduce the cost of CB while ensuring reliable interruption. The impact of various parameters on CB performance is analyzed using numerical calculations to optimize the parameters. Then, a simulation model of a 500 kV/16 kA DCCB is built in PSCAD/EMTDC, and the performance of the proposed CB topology is compared with the other CB topologies. By comparison, the proposed DCCB topology can reliably isolate fault currents and reduce the amplitude of fault currents and the cost of CBs. Significantly, the energy absorbed by the metal oxide varistor (MOV) during the interruption process decreases by 64.2%, reducing the cost and volume of the MOV. Finally, the feasibility of the CB is further verified in the ±500 kV 4-terminal high-voltage DC power grid simulation model. The results show that the proposed DCCB topology can limit the fault current rise rate, interrupt and isolate the fault reliably, and reduce the cost.
2 February 2024 in International Journal of Electrical Power & Energy Systems