Measurement of transformer oil quality plays an important role in health condition monitoring of a transformer. The breakdown voltage (BDV) of transformer oil is influenced by both water content and temperature variation. Therefore, accurate assessment of water content in transformer oil and variation of breakdown voltage due to change in temperature are essential for health condition monitoring of a transformer. It helps to estimate the life expectancy of a transformer. This paper presents a Polymer Optical Fiber Sensor Based Instrumentation System (POFSBIS) to measure the water content in transformer oil of a transformer. Further, the POFSBIS is also used to detect the effect of transformer oil breakdown under controlled laboratory environment. Ultraviolet visual spectrophotometer have been employed to study the changing temperature effect and voltage breakdown effect on transformer oil. The instrumentation system measures the water content in transformer oil as well as provides the online information about the breakdown occurrence in transformer oil which helps to prevent the catastrophic losses of a transformer.
Landslide is a very common natural hazard particularly in the hilly areas. Till now landslide causes a loss of around 1000 million lives and also 4 billion of property. Asia witnesses 220 landslides in the past century. This paper will focus on the various techniques for mapping, monitoring and modeling of landside for prior warning of landslide in landslide prone area. This paper also gives a brief description on the landslide monitoring using point sensors and optical sensors as a whole and its comparison with the conventional methods. The landslide mapping, monitoring and modeling schemes in reference to Guwahati city are also discussed briefly.
16 January 2024 in Bhartiya Krishi Anusandhan Patrika
Background: Muga is an exclusive golden-colored silk produced by the Antheraea Assamensis silkworm species in North-east India. In the silk processing stage, drying of Muga silkworm cocoon is essential to prevent the pupa from emerging from the shell and to preserve the cocoons for a longer period (3-6 months). It is necessary to reduce the potentially harmful high moisture level in the cocoon shell and pupa body to an optimum or safe level of moisture content (6-12%). In India, the natural sun drying method is the most common method to preserve Muga cocoons for a longer period. Considerably losses may occur using the sun-drying method due to various effects such as rodents, insects, rain, microorganisms, excessive temperature, etc. To address this issue the study was conducted to improve the quality of Muga silk yield using a comparative study between Convection and IR heating methods for cocoon drying. Methods: In this study, Muga cocoons were dried properly at optimum temperature (50-100°C) to obtain a safe moisture level for getting quality Muga silk. The drying of the Muga cocoon is processed using convection (1 kw) and Infrared (650 watts) modes of heating for the same duration of time. Muga cocoons were placed in a drying chamber initially at a high temperature (100±5°C) using both convection and Infrared heating methods separately to maintain the moisture content to an optimum level. It took approximately 75 minutes to obtain the temperature 100 from room temperature and every 15 minutes temperature measure was recorded for both methods and compared. The parameters studied were temperature, time, cocoon weight, shell weight, shell ratio and moisture content. These parameters were examined, evaluated and compared for both the Convection and IR heating methods. Result: The comparative study results indicated that the performance of the studied cocoon parameters namely temperature, cocoon weight, shell weight, shell ratio and moisture content are approximately similar for both convection and IR heating methods. Moisture content was maintained at the optimum range (6-12%) for both the convection and IR methods. The study provided a better performance using the IR heating method as compared to convection heating concerning energy consumption and safety for the same duration of time. Energy consumed by a 1 kW convection heater is 1.25 kWh, whereas energy consumption in a 650-watt IR heater is 0.8125 kWh.