In this paper, a hexagonal prism inlet chamber is used to form a swirling flow for the film cooling, and three kinds of compound angle of film hole (γ = 10°, 20°, 30°) with clockwise swirling or counterclockwise swirling are used for numerical simulation studies. The influence of different compound angles of film hole and the swirling directions for the film cooling effectiveness are obtained. The results show that the film cooling effectiveness and spanwise cooling coverage range of the clockwise swirling or counterclockwise swirling flow both are low when the compound angle of film hole is 10°. With the increasing compound angle of film hole, the kidney shaped vortex of film hole exit gradually weakens until it disappears, which reduces the entrainment effect by the coolant jet. So that the spanwise coverage range of two swirling modes is obviously improved. When the compound angle of film hole is 30° compared to 10°, the average spanwise film cooling effectiveness of clockwise swirling and counterclockwise swirling are increased by about 133.75 and 212.6%, respectively. The average spanwise film cooling effectiveness on the downstream of film hole for counterclockwise swirling is increased by about 140% compared with clockwise swirling.
The variable geometry turbine (VGT) adjustable guide vane (AGV) is a key component in next-generation variable cycle engines, with its flow control capability and aerodynamic performance playing a crucial role in the turbine and overall engine performance. The AGV controls flow capacity by rotating the blade angle, which inevitably results in tip clearances at both ends of the blades. In this study, the rationality of the tip clearance setting on both sides of the AGV sector cascade in the experiment is systematically studied, and the influence of the tip clearance effect on the periodicity parameters of the flow field is revealed by experimental means. Under the three typical angular displacement conditions of −10°, 0°, and +10°, the five-hole probe flow field measurement, pressure and aerodynamic torque measurement techniques were comprehensively used to quantitatively characterize the influence of tip clearance on the periodic distribution of six parameters such as flow periodicity, flow angle, total pressure loss coefficient, and aerodynamic torque. The results show that after eliminating the tip clearance on both sides of the cascade, the periodicity deviation of the total pressure loss coefficient at the isentropic Mach number of 0.8 decreases by 0.59%, and the periodicity deviation of the flow angle decreases by 0.76%. Comparing the six periodicity analysis results, the periodicity deviation after the elimination of the tip clearance is smaller than that of the tip clearance setting. Eliminating the tip clearances on both sides can effectively enhance the channel flow periodicity. This finding provides a scientific basis for setting the boundary conditions of the VGT AGV vane sector cascade.
The simulation of thermal–fluid–solid coupling in turbines is critically important for design optimization. Historically, most research on thermal–fluid–solid coupling has been conducted in three-dimensional, often with computational speeds that do not meet practical expectations. This study proposes a one-dimensional performance prediction and multi-objective optimization design methodology for turbines, integrating aerothermodynamics and structural strength, to facilitate rapid multidisciplinary coupling design optimization at a low-dimensional level. Initially, a multidisciplinary coupled turbine performance prediction model is established, incorporating the combined effects of turbine aerothermodynamics and structural mechanics. This model links the thermodynamics of the blade passage with the stress and strain of the blade. The predictive accuracy of this model is validated against experimental data from a four-stage axial flow turbine, showing a maximum error of 1.56% for the total temperature ratio and 1.69% for the total expansion ratio. Subsequently, using blade parameters, degree of reaction, load coefficient, and flow coefficient as optimization variables and targeting the turbine's overall isentropic efficiency and power as optimization objectives, a rapid Non-dominated Sorting Genetic Algorithm II and the Technique for Order Preference by Similarity to an Ideal Solution are employed to optimize the last stage of the four-stage axial flow turbine. The optimized turbine demonstrates an increase in overall isentropic efficiency by 1.333% and an increase in overall power by 3.329%, while satisfying structural strength requirements. The novelty of this study lies in its rapid optimization design and performance prediction method for the coupled aerothermodynamics and structural mechanics at a one-dimensional level.
24 August 2023 in International Journal of Turbo & Jet-Engines
As turbine operating conditions change, the blade height and tip clearance undergo continuous alterations due to the combined effects of thermal stress, aerodynamic forces and centrifugal forces, subsequently influencing the turbine performance. To take this effect into account in turbine performance prediction, this study considers the influence of fluid-heat-structure coupling on blade height and tip clearance and establishes a one-dimensional comprehensive prediction method for multi-stage axial turbine performance considering blade height. When compared with experimental results from a four-stage axial turbine, by considering the fluid-thermal-solid coupling effects, the average relative error in total pressure ratio prediction is reduced from 3.76 % to 1.99 % and the average relative error in total temperature ratio prediction is reduced from 2.03 % to 1.26 %. Compared with the traditional flow prediction method, the prediction results of turbine characteristics considering blade height and tip clearance changes in this paper are closer to the experimental results.