The dissociative electron attachment to the gas phase nucleobase adenine is studied using two different experiments. A double focusing sector field mass spectrometer is utilized for measurements requiring high mass resolution, high sensitivity, and relative ion yields for all the fragment anions and a hemispherical electron monochromator instrument for high electron energy resolution. The negative ion mass spectra are discussed at two different electron energies of 2 and 6eV. In contrast to previous gas phase studies a number of new negative ions are discovered in the mass spectra. The ion efficiency curves for the negative ions of adenine are measured for the electron energy range from about 0to15eV with an electron energy resolution of about 100meV. The total anion yield derived via the summation of all measured fragment anions is compared with the total cross section for negative ion formation measured recently without mass spectrometry. For adenine the shape of the two cross section curves agrees well, taking into account the different electron energy resolutions; however, for thymine some peculiar differences are observed.
1 April 2004 in International Journal of Mass Spectrometry
Atmospheric pressure non-equilibrium plasmas (APPs) are effective source of radicals, metastables and a variety of ions and photons, ranging into the vacuum UV spectral region. A detailed study of these species is important to understand and tune desired effects during the interaction of APPs with solid or liquid materials in industrial or medical applications. In this contribution, the opportunities and challenges of mass spectrometry for detection of neutrals and ions from APPs, fundamental physical phenomena related to the sampling process and their impact on the measured densities of neutrals and fluxes of ions, will be discussed. It is shown that the measurement of stable neutrals and radicals requires a proper experimental design to reduce the beam-to-background ratio, to have little beam distortion during expansion into vacuum and to carefully set the electron energy in the ionizer to avoid radical formation through dissociative ionization. The measured ion composition depends sensitively on the degree of impurities present in the feed gas as well as on the setting of the ion optics used for extraction of ions from the expanding neutral-ion mixture. The determination of the ion energy is presented as a method to show that the analyzed ions are originating from the atmospheric pressure plasma.