Xuetan Zhang

Xuetan Zhang

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2024 in Buildings
Verified
Journal Article
Open access
PDF file
XZXuetan Zhang
Xuetan Zhang
YZYang Zhou
Yang Zhou
XLXiangyu Liu
Xiangyu Liu
YZYaoyu Zheng
Yaoyu Zheng
ZQZhengxin Qi
Zhengxin Qi
This paper studies the impact of half-height infilled walls on the failure modes of frame columns through quasi-static tests of both frame models and half-height infilled wall frame models. Based on the experimental results, a seismic analysis model of reinforced concrete (RC) frame structures is established, and parametric studies are carried out to analyze the effects of masonry materials and masonry heights on the seismic performance of structures. The results show that the load-bearing capacity and stiffness of the structure are improved, while the ductility of the structure is reduced because of the existence of infilled walls. As the height of infilled walls increases, there is a notable decrease in the free height of frame columns. At a wall-to-column height ratio of 0.2, the masonry walls exert a negligible effect on the frame structure’s seismic performance. In contrast, at a ratio of 0.6, there is a transition in column failure modes from bending to shearing. When evaluated at consistent masonry heights, aerated concrete block-infilled walls demonstrate the least impact on the seismic performance of RC frame structures. Thus, in the absence of additional structural enhancements, the use of aerated concrete blocks is recommended to mitigate the negative implications of infilled walls on the seismic integrity of RC frames.

1 June 2024 in Buildings
Verified
Journal Article
Open access
PDF file
YZYang Zhou
Yang Zhou
XLXiangyu Liu
Xiangyu Liu
XZXuetan Zhang
Xuetan Zhang
BOBuildings Editorial Office
Buildings Editorial Office
In order to improve the seismic performance of reinforced concrete (RC) frames, carbon fiber-reinforced polymer (CFRP) was used to retrofit reinforced concrete frame structures. The comparison pseudo-static test results show that the peak load, initial stiffness and ductility of the CFRP retrofitted model were increased by 43.89%, 39.27% and 30.1%, respectively. Based on the parametric study of the finite element model, the contribution of CFRP to the seismic upgrading effect of RC columns was quantitatively revealed, and an optimized design of retrofitted CFRP was proposed. The results show that the peak load, ductility and energy dissipation capacity of the whole structure are improved by using CFRP full-wrap reinforcement and strip reinforcement models with different coverage areas. The damage degree of the column decreases, the damage degree of the beam increases, and the failure mode changes from “column hinge” to “beam hinge”. Simultaneously, different CFRP reinforcement areas and the distance between strip CFRP have different reinforcement effects on concrete structures. Based on the investigation results, the recommended ratio of CFRP strip to spacing is 1 to 1.25.